Siemens
Siemens 5SV RCCB 2P 25–63 A 30mA Type AC 6kA | Earth Leakage Circuit Breaker
Siemens 5SV RCCB 2P 25–63 A 30mA Type AC 6kA | Earth Leakage Circuit Breaker
Couldn't load pickup availability
The Siemens 5SV is a 2P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.
Key features
- 30 mA sensitivity for protection of people against electric shock
- 2P version for single-phase supplies
- Test button for periodic checking of correct operation
- Trip and contact-position indication
- DIN-rail mounting next to MCBs in the same board
- Use with an upstream MCB/MCCB for overload and short-circuit protection
Technical specifications
| Brand | Siemens |
|---|---|
| Part number / model | 5SV |
| Device type | Residual current circuit breaker (RCCB / ELCB) |
| Number of poles | 2P |
| Rated current | 25–63 A |
| Sensitivity (IΔn) | 30 mA |
| Residual current type | Type AC |
| Short-circuit withstand | 6 kA |
| Rated voltage | 230/400 V AC, 50/60 Hz |
| Mounting | 35 mm DIN rail |
| Standard | IEC/EN 61008-1 |
Available versions
Current and Poles: 25A / 2P, 40A / 2P, 63A / 2P, 25A / 4P, 40A / 4P, 63A / 4P.
Typical applications
- Apartment and villa main distribution boards
- Bathrooms, kitchens, outdoor sockets and wet areas
- Offices, schools, clinics and commercial buildings
- Water heater, pump and swimming-pool circuits
- Compliance with Egyptian electrical code requirements for earth-leakage protection
Selection and installation tips
Use 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.
Frequently asked questions
Does the Siemens 5SV protect against short circuits?
No. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.
Why does an RCCB trip frequently?
Usually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.
What is the difference between an RCCB and an RCBO?
An RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.
Buy Siemens 5SV in Egypt
Spark Egypt supplies the original Siemens 5SV residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants, retailers and maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.
Share