Schneider Electric
Schneider Electric GZ1E01 Easy TeSys GZ1E Motor Circuit Breaker 3P 0.1–0.16 A Thermal-Magnetic | MPCB
Schneider Electric GZ1E01 Easy TeSys GZ1E Motor Circuit Breaker 3P 0.1–0.16 A Thermal-Magnetic | MPCB
Couldn't load pickup availability
The Schneider Electric GZ1E01 is a Easy TeSys GZ1E thermal-magnetic motor circuit breaker with a setting range of 0.1–0.16 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.
Key features
- Adjustable thermal setting 0.1–0.16 A to match the motor nameplate current
- Phase-failure sensitivity for three-phase motors
- Clear ON/OFF/TRIP indication and lockable handle for safe maintenance
- Direct mounting with TeSys contactors to build compact starters
- Accepts auxiliary contacts, fault signalling contacts and undervoltage releases
- DIN-rail or panel mounting
Technical specifications
| Brand | Schneider Electric |
|---|---|
| Part number (SKU) | GZ1E01 |
| Product range | Easy TeSys GZ1E |
| Device type | Motor circuit breaker / manual motor starter (MPCB) |
| Protection | thermal-magnetic (overload + short circuit + phase loss) |
| Setting / rated current | 0.1–0.16 A |
| Typical motor power (400 V AC-3) | ≈ 0.03 kW |
| Poles | 3P |
| Control | Rotary handle |
| Mounting | 35 mm DIN rail or panel |
| Standard | IEC/EN 60947-2, IEC/EN 60947-4-1 |
Typical applications
- Water pumps, booster sets and fire pumps
- Fans, blowers, compressors and conveyors
- HVAC, chiller and cooling-tower motors
- Machine control panels and MCCs
- Direct-on-line motor starters
Selection guide
Select the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.
Frequently asked questions
What motor size suits the GZ1E01?
With a 0.1–0.16 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.03 kW at 400 V.
Do I need an overload relay with this breaker?
No for thermal-magnetic GV2ME/GV2P/GV3P/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.
Buy Schneider GZ1E01 in Egypt
Spark Egypt supplies the original Schneider Electric GZ1E01 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.