Schneider Electric
Schneider Electric GoPact MCCB 125 Molded Case Circuit Breakers MCCB
Schneider Electric GoPact MCCB 125 Molded Case Circuit Breakers MCCB
Couldn't load pickup availability
Schneider Electric GoPact MCCB 125 Molded Case Circuit Breakers MCCB
Select a molded case circuit breaker for the main incomer, outgoing feeder or distribution panel. The frame, rated current, number of protected poles, trip unit and breaking capacity must all suit the installation.
Each model below has its own part number and electrical specification. Select the reference that matches the equipment schedule; the selected variant determines the price and availability.
Models and technical specifications
| Part number | Designation | Electrical ratings |
|---|---|---|
| G12E3F100 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 100A rating, TMD trip unit, fixed thermal protection | Current: 100A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3F40 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 40A rating, TMD trip unit, fixed thermal protection | Current: 40A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3F50 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 50A rating, TMD trip unit, fixed thermal protection | Current: 50A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3F80 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 80A rating, TMD trip unit, fixed thermal protection | Current: 80A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12F3F50 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 50A rating, TMD trip unit, fixed thermal protection | Current: 50A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 30kA |
| G12T3F32 | GoPact | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 32A rating, TMD trip unit, fixed thermal protection | Current: 32A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3F40 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 40A rating, TMD trip unit, fixed thermal protection | Current: 40A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12E3A125 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 125A rating, TMD trip unit, adjustable thermal protection | Current: 125A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3A16 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 16A rating, TMD trip unit, adjustable thermal protection | Current: 16A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3A20 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 20A rating, TMD trip unit, adjustable thermal protection | Current: 20A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3A32 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 32A rating, TMD trip unit, adjustable thermal protection | Current: 32A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3A80 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 32A rating, TMD trip unit, fixed thermal protection | Current: 32A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3F16 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 16A rating, TMD trip unit, fixed thermal protection | Current: 16A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3F63 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 63A rating, TMD trip unit, fixed thermal protection | Current: 63A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12F3A16 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 16A rating, TMD trip unit, adjustable thermal protection | Current: 16A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 30kA |
| G12F3A20 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 20A rating, TMD trip unit, adjustable thermal protection | Current: 20A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 30kA |
| G12F3A25 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 25A rating, TMD trip unit, adjustable thermal protection | Current: 25A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 30kA |
| G12F3A32 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 32A rating, TMD trip unit, adjustable thermal protection | Current: 32A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 30kA |
| G12F3A40 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 40A rating, TMD trip unit, adjustable thermal protection | Current: 40A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 30kA |
| G12T3A100 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 100A rating, TMD trip unit, adjustable thermal protection | Current: 100A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3A125 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 125A rating, TMD trip unit, adjustable thermal protection | Current: 125A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3A16 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 16A rating, TMD trip unit, adjustable thermal protection | Current: 16A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3A20 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 20A rating, TMD trip unit, adjustable thermal protection | Current: 20A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3A32 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 32A rating, TMD trip unit, adjustable thermal protection | Current: 32A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3A40 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 40A rating, TMD trip unit, adjustable thermal protection | Current: 40A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3A50 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 50A rating, TMD trip unit, adjustable thermal protection | Current: 50A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12T3A63 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 63A rating, TMD trip unit, adjustable thermal protection | Current: 63A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
| G12E3A40 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 40A rating, TMD trip unit, adjustable thermal protection | Current: 40A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12E3A50 | GoPact | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 50A rating, TMD trip unit, adjustable thermal protection | Current: 50A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 15kA |
| G12T3A25 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 25A rating, TMD trip unit, adjustable thermal protection | Current: 25A; Voltage: 415VAC; Poles: 3 poles; Breaking capacity: 10kA |
Selection and installation
Use the exact part number when ordering replacement parts. Have a qualified electrical professional check the supply, load, protective coordination and manufacturer wiring instructions before commissioning. Accessories shown in application photographs are supplied only when explicitly included in the selected model designation.