Schneider Electric
Schneider Electric G12E3F125 GoPact MCCB GoPact 125E 3P 125A 15kA TMD | Molded Case Circuit Breaker
Schneider Electric G12E3F125 GoPact MCCB GoPact 125E 3P 125A 15kA TMD | Molded Case Circuit Breaker
Couldn't load pickup availability
The Schneider Electric G12E3F125 is a GoPact GoPact 125E molded case circuit breaker rated 125A, 3-pole, with 15 kA breaking capacity and a fixed thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.
Key features
- Fixed thermal-magnetic protection
- Breaking capacity 15 kA for installations with high fault levels
- 3-pole version for three-phase networks
- Positive contact indication and suitable for isolation
- Wide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles
- Compact frame that fits standard switchboards and panel enclosures
Technical specifications
| Brand | Schneider Electric |
|---|---|
| Part number (SKU) | G12E3F125 |
| Product range | GoPact |
| Device type | Molded case circuit breaker (MCCB) |
| Model / frame | GoPact 125E – 125 A frame |
| Rated current (In) | 125A |
| Number of poles | 3P/3D |
| Breaking capacity (Icu) | 15 kA at 380/415 V AC |
| Trip unit | fixed thermal-magnetic |
| Rated operational voltage | up to 415/440 V AC (see datasheet) |
| Mounting | Fixed, front connection |
| Standard | IEC/EN 60947-2 |
Typical applications
- Main and sub-main distribution boards (MDB / SMDB)
- Transformer, generator and ATS panels
- Pump, HVAC, chiller and elevator feeders
- Factories, malls, hospitals, towers and data centres
- Replacement of old MCCBs in existing switchboards
Selection guide
Choose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.
Frequently asked questions
What is the breaking capacity of the G12E3F125?
The G12E3F125 (GoPact 125E) has a breaking capacity of 15 kA at 380/415 V AC.
What is the difference between MCCB and MCB?
MCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.
Which accessories fit this breaker?
GoPact breakers accept auxiliary/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.
Buy Schneider G12E3F125 in Egypt
Spark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the G12E3F125, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.
Share