Schneider Electric
Schneider Electric ATS480 Soft Starters
Schneider Electric ATS480 Soft Starters
Couldn't load pickup availability
Schneider Electric ATS480 Soft Starters
Limit starting stress with a soft starter selected for the motor current, supply voltage and starting duty. A soft starter is not a variable-speed drive. Confirm the required bypass arrangement and upstream protective coordination.
Each model below has its own part number and electrical specification. Select the reference that matches the equipment schedule; the selected variant determines the price and availability.
Models and technical specifications
| Part number | Designation | Electrical ratings |
|---|---|---|
| ATS480C17Y | Soft starter, Altistart 480, 170A, 208 to 690V AC, control supply 110 to 230V AC | Current: 170A; Voltage: 690V AC, 230V AC |
| ATS480C21Y | Soft starter, Altistart 480, 210A, 208 to 690V AC, control supply 110 to 230V AC | Current: 210A; Voltage: 690V AC, 230V AC |
| ATS480C25Y | Soft starter, Altistart 480, 250A, 208 to 690V AC, control supply 110 to 230V AC | Current: 250A; Voltage: 690V AC, 230V AC |
| ATS480C32Y | Soft starter, Altistart 480, 320A, 208 to 690V AC, control supply 110 to 230V AC | Current: 320A; Voltage: 690V AC, 230V AC |
| ATS480C48Y | Soft starter, Altistart 480, 480A, 208 to 690V AC, control supply 110 to 230V AC | Current: 480A; Voltage: 690V AC, 230V AC |
| ATS480C66Y | Soft starter, Altistart 480, 660A, 208 to 690V AC, control supply 110 to 230V AC | Current: 660A; Voltage: 690V AC, 230V AC |
| ATS480C79Y | Soft starter, Altistart 480, 790A, 208 to 690V AC, control supply 110 to 230V AC | Current: 790A; Voltage: 690V AC, 230V AC |
| ATS480D38Y | Soft starter, Altistart 480, 38A, 208 to 690V AC, control supply 110 to 230V AC | Current: 38A; Voltage: 690V AC, 230V AC |
| ATS480D62Y | Soft starter, Altistart 480, 62A, 208 to 690V AC, control supply 110 to 230V AC | Current: 62A; Voltage: 690V AC, 230V AC |
| ATS480D75Y | Soft starter, Altistart 480, 75A, 208 to 690V AC, control supply 110 to 230V AC | Current: 75A; Voltage: 690V AC, 230V AC |
| ATS480D88Y | Soft starter, Altistart 480, 88A, 208 to 690V AC, control supply 110 to 230V AC | Current: 88A; Voltage: 690V AC, 230V AC |
| ATS480C59Y | Soft starter, Altistart 480, 590A, 208 to 690V AC, control supply 110 to 230V AC | Current: 590A; Voltage: 690V AC, 230V AC |
| ATS480M10Y | Soft starter, Altistart 480, 1000A, 208 to 690V AC, control supply 110 to 230V AC | Current: 1000A; Voltage: 690V AC, 230V AC |
Selection and installation
Use the exact part number when ordering replacement parts. Have a qualified electrical professional check the supply, load, protective coordination and manufacturer wiring instructions before commissioning. Accessories shown in application photographs are supplied only when explicitly included in the selected model designation.
Share