Skip to product information
1 of 1

Schneider Electric

Schneider Electric Easy TeSys Control Motor Contactors

Schneider Electric Easy TeSys Control Motor Contactors

Regular price LE 19,678.07 EGP
Regular price Sale price LE 19,678.07 EGP
Sale Sold out
Taxes included.
Model and rating
Quantity

Schneider Electric Easy TeSys Control Motor Contactors

Switch motor or power circuits using the model with the correct utilization category, rated current and coil supply. AC-1, AC-3 and AC-3e ratings are not interchangeable; use the rating for the actual load.

Each model below has its own part number and electrical specification. Select the reference that matches the equipment schedule; the selected variant determines the price and availability.

Models and technical specifications

Part number Designation Electrical ratings
LC1E250M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,250A/190A,220V AC coil,50Hz Current: 250A, 190A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO
LC1E300M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,300A/265A,220V AC coil,50Hz Current: 300A, 265A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO
LC1E2501M7 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,25A,220V AC coil,50/60Hz,1NC auxiliary contact Current: 25A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NC
LC1E2510M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,25A,220V AC coil,50Hz,1NO auxiliary contact Current: 25A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NO
LC1E1210M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,12A,220V AC coil,50Hz,1NO auxiliary contact Current: 12A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NO
LC1E1801M7 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,18A,220V AC coil,50/60Hz,1NC auxiliary contact Current: 18A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NC
LC1E3810M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,38A,220V AC coil,50Hz,1NO auxiliary contact Current: 38A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NO
LC1E500M7 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,500A,220V AC coil Current: 500A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO
LC1E0610M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,6A,220V AC coil,50Hz,1NO auxiliary contact Current: 6A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NO
LC1E0901M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,9A,220V AC coil,50Hz,1NC auxiliary contact Current: 9A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NC
LC1E0901M7 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,9A,220V AC coil,50/60Hz,1NC auxiliary contact Current: 9A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NC
LC1E0910M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,9A,220V AC coil,50Hz,1NO auxiliary contact Current: 9A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NO
LC1E1201E7 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,12A,48V AC coil,50/60Hz,1NC auxiliary contact Current: 12A; Voltage: 440V, 48V AC; Poles: 3P; Contacts: 3NO, 1NC
LC1E1201M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,12A,220V AC coil,50Hz,1NC auxiliary contact Current: 12A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NC
LC1E1201M7 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,12A,220V AC coil,50/60Hz,1NC auxiliary contact Current: 12A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NC
LC1E1810M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,18A,220V AC coil,50Hz,1NO auxiliary contact Current: 18A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO, 1NO
LC1E95M5 Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,95A,220V AC coil,50Hz Current: 95A; Voltage: 440V, 220V AC; Poles: 3P; Contacts: 3NO

Selection and installation

Use the exact part number when ordering replacement parts. Have a qualified electrical professional check the supply, load, protective coordination and manufacturer wiring instructions before commissioning. Accessories shown in application photographs are supplied only when explicitly included in the selected model designation.

View full details