Skip to product information
1 of 1

Hyundai

Hyundai HGM MCCB 3P 16–100 A 20 kA | Molded Case Circuit Breaker

Hyundai HGM MCCB 3P 16–100 A 20 kA | Molded Case Circuit Breaker

Regular price LE 1,785.00 EGP
Regular price Sale price LE 1,785.00 EGP
Sale Sold out
Taxes included.
Rated Current
Quantity

The Hyundai HGM is a 3-pole 16–100 A molded case circuit breaker with 20 kA breaking capacity and a fixed thermal-magnetic trip unit. It protects main incomers, feeders, motors and distribution boards against overload and short circuit in residential towers, commercial buildings and factories. Several current ratings are available under this listing.

Key features

  • Fixed thermal-magnetic protection with factory-set thresholds
  • Breaking capacity 20 kA suitable for main and sub-main boards
  • Rotary or toggle operation with clear ON/OFF/TRIP indication
  • Wide range of accessories: shunt trip, undervoltage release, auxiliary contacts, rotary handles and motor operators
  • Front-connected terminals for cables or busbars

Technical specifications

Brand Hyundai
Part number / model HGM
Device type Molded case circuit breaker (MCCB)
Number of poles 3P
Rated current (In) 16–100 A
Frame size 100 A
Breaking capacity (Icu) 20 kA
Trip unit fixed thermal-magnetic
Rated voltage up to 415/440 V AC
Standard IEC/EN 60947-2

Available versions

Rated Current: 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 75 A, 80 A, 100 A.

Typical applications

  • Main incomers of buildings and distribution boards
  • Feeders to sub-main boards, elevators and pumps
  • Generator and transformer outgoing circuits
  • Motor control centres and industrial panels
  • ATS and changeover panels

Selection and installation tips

Select the MCCB rated current from the design load and cable ampacity, check that the breaking capacity (Icu) exceeds the prospective short-circuit current at the installation point, and choose an adjustable or electronic trip unit when selectivity with downstream breakers is required.

Frequently asked questions

What is the difference between an MCCB and an MCB?

MCCBs cover higher currents (typically 16–1600 A), higher breaking capacities and often adjustable protection, while MCBs are modular devices up to about 125 A for final circuits.

What does Icu mean?

Icu is the ultimate short-circuit breaking capacity – the highest fault current the breaker can safely interrupt.

Buy Hyundai HGM in Egypt

Order the Hyundai HGM molded case circuit breaker (MCCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.

View full details