Skip to product information
1 of 1

ABB

ABB FH202 AC-63/0.03 RCCB 2P 63 A 30mA Type AC | 2CSF202006R1630

ABB FH202 AC-63/0.03 RCCB 2P 63 A 30mA Type AC | 2CSF202006R1630

Regular price LE 2,695.50 EGP
Regular price LE 3,284.00 EGP Sale price LE 2,695.50 EGP
Sale Sold out
Taxes included.
Product
Quantity

The ABB FH202 AC-63/0.03 (2CSF202006R1630) is a 2P, 63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.

Key features

  • 30 mA sensitivity for protection of people against electric shock
  • 2P version for single-phase supplies
  • Test button for periodic checking of correct operation
  • Trip and contact-position indication
  • DIN-rail mounting next to MCBs in the same board
  • Use with an upstream MCB/MCCB for overload and short-circuit protection

Technical specifications

Brand ABB
Part number / model FH202 AC-63/0.03
Product range FH200 RCCB
ABB order code 2CSF202006R1630
Device type Residual current circuit breaker (RCCB / ELCB)
Number of poles 2P
Rated current 63 A
Sensitivity (IΔn) 30 mA
Residual current type Type AC
Rated voltage 230/400 V AC, 50/60 Hz
Mounting 35 mm DIN rail
Standard IEC/EN 61008-1

Typical applications

  • Apartment and villa main distribution boards
  • Bathrooms, kitchens, outdoor sockets and wet areas
  • Offices, schools, clinics and commercial buildings
  • Water heater, pump and swimming-pool circuits
  • Compliance with Egyptian electrical code requirements for earth-leakage protection

Selection and installation tips

Use 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.

Frequently asked questions

Does the ABB FH202 AC-63/0.03 protect against short circuits?

No. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.

Why does an RCCB trip frequently?

Usually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.

What is the difference between an RCCB and an RCBO?

An RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.

Buy ABB FH202 AC-63/0.03 in Egypt

Spark Egypt supplies the original ABB FH202 AC-63/0.03 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants, retailers and maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.

View full details