{"product_id":"telemecanique-sensors-xs1-m12-inductive-proximity-sensor-sn-2-mm-12-24-vdc","title":"Telemecanique Sensors XS1 M12 Inductive Proximity Sensor | Sn 2 mm 12-24 VDC","description":"\u003cp\u003e\u003cstrong\u003eTelemecanique Sensors XS1 M12 Inductive Proximity Sensor | Sn 2 mm 12-24 VDC\u003c\/strong\u003e is a Telemecanique Sensors inductive proximity sensor range for non-contact metal detection in industrial automation, machine safety and control-panel applications.\u003c\/p\u003e\u003cp\u003eThe XS1 M12 family uses a robust cylindrical M12 body with Sn 2 mm sensing distance, making it suitable for detecting machine position, metal targets, conveyors, packaging machines, pump skids, production lines, elevators, gates and OEM equipment. These sensors help engineers and maintenance teams select the correct PNP, NPN, AC\/DC, NO, NC, cable or M12 plug option for reliable switching in factories, workshops and industrial sites in Egypt.\u003c\/p\u003e\u003ch3\u003eKey applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMetal object detection and position feedback\u003c\/li\u003e\n\u003cli\u003ePLC input sensing for machines and automation panels\u003c\/li\u003e\n\u003cli\u003eConveyors, packaging machines, pump systems, doors and handling equipment\u003c\/li\u003e\n\u003cli\u003eReplacement proximity sensor stock for electrical maintenance teams\u003c\/li\u003e\n\u003c\/ul\u003e\u003c!-- spark-telemecanique-variant-table:start --\u003e\u003ch3\u003eVariant table - inductive proximity sensor part numbers\u003c\/h3\u003e\u003cp\u003eCompare the part numbers by output type, contact logic, sensing distance and connection style before selecting the sensor for a machine, conveyor, pump skid or control panel.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:14px;line-height:1.45;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003ePart number\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eOutput \/ contact\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eSensing distance\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eConnection\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eSupply voltage\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eMain difference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eXS112BLNAL2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eNPN NO\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eSn 2 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e2 m pre-wired cable\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e12-24 VDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eChoose XS112BLNAL2 when the panel requires npn no output with 2 m pre-wired cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eXS112BLPAL2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003ePNP NO\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eSn 2 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e2 m pre-wired cable\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e12-24 VDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eChoose XS112BLPAL2 when the panel requires pnp no output with 2 m pre-wired cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eXS112BLPBL2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003ePNP NC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eSn 2 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e2 m pre-wired cable\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e12-24 VDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eChoose XS112BLPBL2 when the panel requires pnp nc output with 2 m pre-wired cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eXS112BLNAM12\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eNPN NO\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eSn 2 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eM12 plug connector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e12-24 VDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eChoose XS112BLNAM12 when the panel requires npn no output with m12 plug connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eXS112BLPAM12\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003ePNP NO\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eSn 2 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eM12 plug connector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e12-24 VDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eChoose XS112BLPAM12 when the panel requires pnp no output with m12 plug connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eXS112BLPBM12\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003ePNP NC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eSn 2 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eM12 plug connector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e12-24 VDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eChoose XS112BLPBM12 when the panel requires pnp nc output with m12 plug connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eXS112BHPBM12\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003ePNP NC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eSn 4 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eM12 plug connector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e12-24 VDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eChoose XS112BHPBM12 when the panel requires pnp nc output with m12 plug connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c!-- spark-telemecanique-variant-table:end --\u003e\u003ch3\u003eWhy buy from Spark Egypt\u003c\/h3\u003e\u003cp\u003eSpark supplies Telemecanique sensors and pressure switches for engineers, contractors, panel builders and maintenance teams who need genuine industrial automation components, clear part-number selection and dependable local sourcing in Cairo and across Egypt.\u003c\/p\u003e","brand":"Telemecanique","offers":[{"title":"NPN NO, cable 2m (XS112BLNAL2)","offer_id":51880751169821,"sku":"XS112BLNAL2","price":1394.27,"currency_code":"EGP","in_stock":true},{"title":"PNP NO, cable 2m (XS112BLPAL2)","offer_id":51880751202589,"sku":"XS112BLPAL2","price":1600.5,"currency_code":"EGP","in_stock":true},{"title":"PNP NC, cable 2m (XS112BLPBL2)","offer_id":51880751235357,"sku":"XS112BLPBL2","price":1625.19,"currency_code":"EGP","in_stock":true},{"title":"NPN NO, M12 plug (XS112BLNAM12)","offer_id":51880751268125,"sku":"XS112BLNAM12","price":1615.03,"currency_code":"EGP","in_stock":true},{"title":"PNP NO, M12 plug (XS112BLPAM12)","offer_id":51880751300893,"sku":"XS112BLPAM12","price":1600.5,"currency_code":"EGP","in_stock":true},{"title":"PNP NC, M12 plug (XS112BLPBM12)","offer_id":51880751333661,"sku":"XS112BLPBM12","price":1802.38,"currency_code":"EGP","in_stock":true},{"title":"PNP NC, Sn4mm, M12 plug (XS112BHPBM12)","offer_id":51880751366429,"sku":"XS112BHPBM12","price":1629.55,"currency_code":"EGP","in_stock":true}],"url":"https:\/\/www.spark-eshop.com\/products\/telemecanique-sensors-xs1-m12-inductive-proximity-sensor-sn-2-mm-12-24-vdc","provider":"Spark","version":"1.0","type":"link"}