{"product_id":"siemens-3va1116-4ef36-0aa0-mccb-3p-160a-36ka","title":"Siemens 3VA1116-4EF36-0AA0 MCCB 3P 160 A 36 kA | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-4EF36-0AA0 is a 3-pole 160 A molded case circuit breaker with 36 kA breaking capacity and a fixed thermal-magnetic trip unit. It protects main incomers, feeders, motors and distribution boards against overload and short circuit in residential towers, commercial buildings and factories.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFixed thermal-magnetic protection with factory-set thresholds\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA suitable for main and sub-main boards\u003c\/li\u003e\n\u003cli\u003eRotary or toggle operation with clear ON\/OFF\/TRIP indication\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: shunt trip, undervoltage release, auxiliary contacts, rotary handles and motor operators\u003c\/li\u003e\n\u003cli\u003eFront-connected terminals for cables or busbars\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3VA1116-4EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003efixed thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain incomers of buildings and distribution boards\u003c\/li\u003e\n\u003cli\u003eFeeders to sub-main boards, elevators and pumps\u003c\/li\u003e\n\u003cli\u003eGenerator and transformer outgoing circuits\u003c\/li\u003e\n\u003cli\u003eMotor control centres and industrial panels\u003c\/li\u003e\n\u003cli\u003eATS and changeover panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eSelect the MCCB rated current from the design load and cable ampacity, check that the breaking capacity (Icu) exceeds the prospective short-circuit current at the installation point, and choose an adjustable or electronic trip unit when selectivity with downstream breakers is required.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between an MCCB and an MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16–1600 A), higher breaking capacities and often adjustable protection, while MCBs are modular devices up to about 125 A for final circuits.\u003c\/p\u003e\u003ch3\u003eWhat does Icu mean?\u003c\/h3\u003e\u003cp\u003eIcu is the ultimate short-circuit breaking capacity – the highest fault current the breaker can safely interrupt.\u003c\/p\u003e\n\u003ch2\u003eBuy Siemens 3VA1116-4EF36-0AA0 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Siemens 3VA1116-4EF36-0AA0 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants, retailers and maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"160112 - 160 A","offer_id":51559057916189,"sku":"3VA1116-4EF36-0AA0","price":23039.25,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/G_I202_XX_24636i.jpg?v=1780095649","url":"https:\/\/www.spark-eshop.com\/products\/siemens-3va1116-4ef36-0aa0-mccb-3p-160a-36ka","provider":"Spark","version":"1.0","type":"link"}