{"product_id":"schneider-gz1e04-easy-tesys-gz1e-motor-circuit-breaker-0-4-0-63-a","title":"Schneider Electric GZ1E04 Easy TeSys GZ1E Motor Circuit Breaker 3P 0.4–0.63 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GZ1E04 is a Easy TeSys GZ1E thermal-magnetic motor circuit breaker with a setting range of 0.4–0.63 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.4–0.63 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGZ1E04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eEasy TeSys GZ1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.4–0.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.18 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GZ1E04?\u003c\/h3\u003e\u003cp\u003eWith a 0.4–0.63 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.18 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GZ1E04 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GZ1E04 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592857885,"sku":"GZ1E04","price":1329.32,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_1c38ffbf-33f7-404c-acf6-460b10c20d13.png?v=1779987567","url":"https:\/\/www.spark-eshop.com\/products\/schneider-gz1e04-easy-tesys-gz1e-motor-circuit-breaker-0-4-0-63-a","provider":"Spark","version":"1.0","type":"link"}