{"product_id":"schneider-electric-tesys-d-contactor-lc1d32-32a-3p-ac3","title":"Schneider Electric TeSys D Contactor LC1D32 | 3-Pole AC-3 32A Motor Contactor","description":"\u003cp\u003e\u003cstrong\u003eSchneider Electric LC1D32 TeSys D contactor\u003c\/strong\u003e is a genuine Schneider Electric 3-pole TeSys D AC contactor for reliable motor switching, control-panel assembly and industrial automation projects.\u003c\/p\u003e\u003cp\u003eDesigned for \u003cstrong\u003eAC-3 motor duty\u003c\/strong\u003e, the LC1D32 32A AC-3 contactor supports low-voltage electrical panels, pump control, HVAC systems, compressors, machinery control, production lines, building services and maintenance replacement jobs. It is a practical choice for electrical contractors, panel builders, factories and facility teams in Egypt looking for dependable Schneider Electric motor-control components from Spark.\u003c\/p\u003e\u003ch3\u003eKey specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBrand: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: TeSys D \/ LC1D\u003c\/li\u003e\n\u003cli\u003eCurrent rating: 32A\u003c\/li\u003e\n\u003cli\u003ePoles: 3P, 3 normally-open main contacts\u003c\/li\u003e\n\u003cli\u003eUtilization category: AC-3 motor control\u003c\/li\u003e\n\u003cli\u003eOperational voltage: up to 440V AC for AC-3 duty\u003c\/li\u003e\n\u003cli\u003eMotor duty reference: up to 15kW at 400V depending on motor duty and installation conditions\u003c\/li\u003e\n\u003cli\u003eApplications: direct-on-line starters, reversing starters, control panels, MCC panels, LV switchboards and automation systems\u003c\/li\u003e\n\u003cli\u003eAvailable part numbers \/ SKUs: LC1D32M7, LC1D32B7, LC1D32E7, LC1D32F7, LC1D32Q7, LC1D32BD\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eOrder Schneider Electric TeSys D contactors from Spark Egypt for industrial motor starters, genuine electrical spare parts, LV panel components and fast local sourcing for Cairo, Giza and projects across Egypt.\u003c\/p\u003e\n\n\u003c!-- spark-variant-table:start --\u003e\u003ch3\u003eVariant guide and coil-voltage differences\u003c\/h3\u003e\u003cp\u003eUse this table to choose the correct Schneider Electric TeSys D variant by control-coil voltage while keeping the same 3-pole AC-3 contactor frame.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:14px;line-height:1.45;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eVariant SKU\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eCoil voltage\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eAC-3 current\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eMotor duty reference\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:10px;background:#f5f7f6;text-align:left;font-weight:700;\"\u003eMain difference \/ best use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLC1D32M7\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e220V AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e15kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eCommon 220\/230V AC control supply for Egyptian LV panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLC1D32B7\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e24V AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e15kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLow-voltage AC control circuits, transformer-fed panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLC1D32E7\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e48V AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e15kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e48V AC control systems and machine control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLC1D32F7\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e110V AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e15kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e110V AC industrial control panels and imported machinery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLC1D32Q7\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e380V AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e15kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLine-voltage AC control supply where a neutral is not used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eLC1D32BD\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e24V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003e15kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:10px;vertical-align:top;\"\u003eDC control circuits, PLC outputs and battery-backed control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c!-- spark-variant-table:end --\u003e","brand":"Schneider Electric","offers":[{"title":"LC1D32M7 - 220VAC","offer_id":51373358252317,"sku":"LC1D32M7","price":2971.9,"currency_code":"EGP","in_stock":true},{"title":"LC1D32B7 - 24VAC","offer_id":51373358285085,"sku":"LC1D32B7","price":3388.0,"currency_code":"EGP","in_stock":true},{"title":"LC1D32E7 - 48VAC","offer_id":51373358317853,"sku":"LC1D32E7","price":3388.0,"currency_code":"EGP","in_stock":true},{"title":"LC1D32F7 - 110VAC","offer_id":51373358350621,"sku":"LC1D32F7","price":3388.0,"currency_code":"EGP","in_stock":true},{"title":"LC1D32Q7 - 380VAC","offer_id":51373358383389,"sku":"LC1D32Q7","price":3388.0,"currency_code":"EGP","in_stock":true},{"title":"LC1D32BD - 24VDC","offer_id":51373358416157,"sku":"LC1D32BD","price":3388.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/LC1D32BD_TeSysDcontactor-3P_3NO_-AC-3-__440V32A-24VDCcoil.jpg?v=1779698177","url":"https:\/\/www.spark-eshop.com\/products\/schneider-electric-tesys-d-contactor-lc1d32-32a-3p-ac3","provider":"Spark","version":"1.0","type":"link"}