{"product_id":"lovato-motor-protection-breakers","title":"Lovato SM Motor Protection Circuit Breakers | Adjustable MPCB 0.63-100A","description":"\u003cdiv\u003e\n\u003cp\u003eLovato SM manual motor protection circuit breakers combine adjustable thermal motor protection with magnetic short-circuit tripping. SM1P push-button models and SM1R, SM2R and SM3R rotary-handle models cover different motor currents and panel requirements. Breaking capacity is specific to the selected model and supply voltage, rather than a single rating for the whole range.\u003c\/p\u003e\n\u003ch2\u003eFeatures and applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable current range shown for each order code\u003c\/li\u003e\n\u003cli\u003ePush-button or rotary operation according to family\u003c\/li\u003e\n\u003cli\u003eModel-specific short-circuit breaking capacity at 400V\u003c\/li\u003e\n\u003cli\u003eOptional auxiliary contacts must match the SM frame\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels and specifications\u003c\/h2\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P0100\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e0.63-1A \/ SM1P0100\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e0.63…1\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e1\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P0100\/snp\"\u003eManufacturer data for SM1P0100\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P0160\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e1-1.6A \/ SM1P0160\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e1…1.6\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e1.6\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P0160\/snp\"\u003eManufacturer data for SM1P0160\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P0250\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e1.6-2.5A \/ SM1P0250\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e1.6…2.5\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e2.5\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P0250\/snp\"\u003eManufacturer data for SM1P0250\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P0400\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e2.5-4A \/ SM1P0400\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e2.5…4\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e4\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P0400\/snp\"\u003eManufacturer data for SM1P0400\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P0650\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e4-6.5A \/ SM1P0650\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e4…6.5\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e6.5\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P0650\/snp\"\u003eManufacturer data for SM1P0650\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P1000\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e6.3-10A \/ SM1P1000\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e6.3…10\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e10\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P1000\/snp\"\u003eManufacturer data for SM1P1000\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P1400\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e9-14A \/ SM1P1400\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e9...14\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e14\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e25\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P1400\/snp\"\u003eManufacturer data for SM1P1400\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P1800\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e13-18A \/ SM1P1800\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e13…18\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e18\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e25\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P1800\/snp\"\u003eManufacturer data for SM1P1800\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P2300\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e17-23A \/ SM1P2300\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e17…23\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e23\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e15\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P2300\/snp\"\u003eManufacturer data for SM1P2300\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P2500\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e20-25A \/ SM1P2500\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e20…25\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e25\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e15\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P2500\/snp\"\u003eManufacturer data for SM1P2500\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P3200\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e24-32A \/ SM1P3200\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e24…32\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e32\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e10\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P3200\/snp\"\u003eManufacturer data for SM1P3200\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1P4000\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e30-40A \/ SM1P4000\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e30…40\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e40\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e10\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003ePush button\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1P4000\/snp\"\u003eManufacturer data for SM1P4000\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1R3200\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e24-32A \/ SM1R3200\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e24…32\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e32\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eRotary knob\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1R3200\/snp\"\u003eManufacturer data for SM1R3200\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM1R4000\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e30-40A \/ SM1R4000\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e30…40\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e40\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e20\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eRotary knob\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eNo\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM1R4000\/snp\"\u003eManufacturer data for SM1R4000\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM2R5000\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e35-50A \/ SM2R5000\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e34…50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eRotary knob\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eYes\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM2R5000\/snp\"\u003eManufacturer data for SM2R5000\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM2R6300\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e46-63A \/ SM2R6300\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e45…63\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e63\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eRotary knob\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eYes\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM2R6300\/snp\"\u003eManufacturer data for SM2R6300\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM3R7500\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e55-75A \/ SM3R7500\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e55…75\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e75\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eRotary knob\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eYes\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM3R7500\/snp\"\u003eManufacturer data for SM3R7500\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM3R9000\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e70-90A \/ SM3R9000\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e70…90\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e90\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eRotary knob\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eYes\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM3R9000\/snp\"\u003eManufacturer data for SM3R9000\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbdi\u003eSM3R9900\u003c\/bdi\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbdi\u003e80-100A \/ SM3R9900\u003c\/bdi\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003eType of product\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMotor protection circuit breaker\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eThermal trip adjustment range [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e80…100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eRated current In [A]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e100\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eShort-circuit current breaking capacity (Icu) at AC 400V [kA]\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003e50\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of protection\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eMagnetic and thermal\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eType of control\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eRotary knob\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003cdt\u003eCertified UL Type E\u003c\/dt\u003e\n\u003cdd\u003e\u003cbdi\u003eYes\u003c\/bdi\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/catalogue.lovatoelectric.com\/gl_en\/SM3R9900\/snp\"\u003eManufacturer data for SM3R9900\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSelection and installation\u003c\/h2\u003e\n\u003cp\u003eSet the thermal adjustment to the motor nameplate current and check the prospective fault current, starting duty and coordination requirements.\u003c\/p\u003e\n\u003cp\u003eAvailable from Spark in Egypt for control-panel assembly, maintenance and electrical projects, with delivery to Cairo, Giza, Alexandria and other governorates. Match the order code, electrical ratings and compatible equipment before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Lovato","offers":[{"title":"0.63-1A \/ SM1P0100","offer_id":67849263186205,"sku":"SM1P0100","price":2676.15,"currency_code":"EGP","in_stock":false},{"title":"1-1.6A \/ SM1P0160","offer_id":67849263218973,"sku":"SM1P0160","price":2676.15,"currency_code":"EGP","in_stock":false},{"title":"1.6-2.5A \/ SM1P0250","offer_id":67849263251741,"sku":"SM1P0250","price":2676.15,"currency_code":"EGP","in_stock":false},{"title":"2.5-4A \/ SM1P0400","offer_id":67849263284509,"sku":"SM1P0400","price":2676.15,"currency_code":"EGP","in_stock":false},{"title":"4-6.5A \/ SM1P0650","offer_id":67849263317277,"sku":"SM1P0650","price":2676.15,"currency_code":"EGP","in_stock":true},{"title":"6.3-10A \/ SM1P1000","offer_id":67849263350045,"sku":"SM1P1000","price":2794.14,"currency_code":"EGP","in_stock":true},{"title":"9-14A \/ SM1P1400","offer_id":67849263382813,"sku":"SM1P1400","price":2794.14,"currency_code":"EGP","in_stock":true},{"title":"13-18A \/ SM1P1800","offer_id":67849263415581,"sku":"SM1P1800","price":2794.14,"currency_code":"EGP","in_stock":true},{"title":"17-23A \/ SM1P2300","offer_id":67849263448349,"sku":"SM1P2300","price":2918.12,"currency_code":"EGP","in_stock":false},{"title":"20-25A \/ SM1P2500","offer_id":67849263481117,"sku":"SM1P2500","price":3221.64,"currency_code":"EGP","in_stock":false},{"title":"24-32A \/ SM1P3200","offer_id":67849263513885,"sku":"SM1P3200","price":4702.5,"currency_code":"EGP","in_stock":false},{"title":"30-40A \/ SM1P4000","offer_id":67849263546653,"sku":"SM1P4000","price":6324.99,"currency_code":"EGP","in_stock":false},{"title":"24-32A \/ SM1R3200","offer_id":67849263579421,"sku":"SM1R3200","price":9505.89,"currency_code":"EGP","in_stock":false},{"title":"30-40A \/ SM1R4000","offer_id":67849263612189,"sku":"SM1R4000","price":10063.35,"currency_code":"EGP","in_stock":false},{"title":"35-50A \/ SM2R5000","offer_id":67849263644957,"sku":"SM2R5000","price":10165.95,"currency_code":"EGP","in_stock":false},{"title":"46-63A \/ SM2R6300","offer_id":67849263677725,"sku":"SM2R6300","price":10571.22,"currency_code":"EGP","in_stock":false},{"title":"55-75A \/ SM3R7500","offer_id":67849263710493,"sku":"SM3R7500","price":11917.85,"currency_code":"EGP","in_stock":false},{"title":"70-90A \/ SM3R9000","offer_id":67849263743261,"sku":"SM3R9000","price":13053.29,"currency_code":"EGP","in_stock":false},{"title":"80-100A \/ SM3R9900","offer_id":67849263776029,"sku":"SM3R9900","price":14535.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/lovato-sm1p4000.jpg?v=1792705233","url":"https:\/\/www.spark-eshop.com\/products\/lovato-motor-protection-breakers","provider":"Spark","version":"1.0","type":"link"}