{"product_id":"abb-2cds272001r0634-s202m-c63-63-a-2p","title":"ABB S202M-C63 MCB 2P 63 A C-Curve 10 kA | 2CDS272001R0634","description":"\u003cp\u003eThe ABB S202M-C63 (2CDS272001R0634) is a 2P 63 A C-curve miniature circuit breaker with 10 kA breaking capacity. It protects cables and connected equipment against overload and short circuit in single-phase circuits where phase and neutral are switched together, and clips onto a standard 35 mm DIN rail in apartment, villa, commercial and industrial distribution boards.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (magnetic trip at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e2P construction for single-phase circuits where phase and neutral are switched together\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10 kA for safe disconnection of short-circuit currents\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF handle with contact position indication for safe isolation\u003c\/li\u003e\n\u003cli\u003eQuick clip-on mounting on 35 mm DIN rail, compatible with standard pin\/fork busbars\u003c\/li\u003e\n\u003cli\u003eCompact modular width for neat, standardised distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eS202M-C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSystem pro M compact S200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CDS272001R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1 \/ IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, shops, schools and hospitals\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty breakers during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eMatch the breaker rating to the cable cross-section (typically 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets, 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the inrush current of the load, and make sure the breaking capacity exceeds the prospective short-circuit current at the board. Add an RCCB or use an RCBO for earth-leakage protection.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the ABB S202M-C63 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 2P 63 A C-curve MCB used to protect single-phase circuits where phase and neutral are switched together against overload and short circuit.\u003c\/p\u003e\u003ch3\u003eDoes an MCB protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection of people against earth leakage use a 30 mA RCCB upstream or an RCBO.\u003c\/p\u003e\u003ch3\u003eWhich MCB rating do I need for an air conditioner?\u003c\/h3\u003e\u003cp\u003eAs a guide, 1.5–2.25 HP split units usually use a 16–20 A C-curve MCB, 3 HP units 25 A and 4–5 HP units 32 A, always matched to the cable size recommended by the manufacturer.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB S202M-C63 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the ABB S202M-C63 miniature circuit breaker (MCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945710682397,"sku":"2CDS272001R0634","price":1586.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2cds272001r0634.jpg?v=1782986016","url":"https:\/\/www.spark-eshop.com\/products\/abb-2cds272001r0634-s202m-c63-63-a-2p","provider":"Spark","version":"1.0","type":"link"}