{"title":"RCCB \u0026 RCBO Earth Leakage Protection","description":"\u003cp\u003eAn RCCB (earth leakage breaker) disconnects the circuit when it detects leakage current to earth, giving additional protection against electric shock and reducing the fire risk from earth-leakage faults; an RCBO adds overload and short-circuit protection in the same device. It complements, but does not replace, correct earthing and circuit protection. Choose 2-pole for single-phase or 4-pole for three-phase, by rated current, sensitivity and type, from Schneider Electric, ABB, Hager, Siemens, Hyundai, Beta Electric and Himel. EGP prices, VAT invoice and delivery across Egypt. Not sure which one you need? \u003ca href=\"https:\/\/wa.me\/201050008395\"\u003eAsk our engineers on WhatsApp\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"schneider-50437-vigirex-closed-toroid-ta30-30mm","title":"Schneider Electric 50437 Vigirex Closed Toroid TA30 Ø30 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50437 is a Vigirex closed toroid with a 30 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50437\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTA30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50437 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric 50437 closed toroid (residual current sensor) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560286493,"sku":"50437","price":10567.8,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_ffaf0d93-100f-49ae-88bf-7b8bd5aa329f.png?v=1780589851"},{"product_id":"schneider-50438-vigirex-closed-toroid-pa50-50mm","title":"Schneider Electric 50438 Vigirex Closed Toroid PA50 Ø50 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50438 is a Vigirex closed toroid with a 50 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50438\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePA50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50438 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric closed toroid (residual current sensor)s such as the 50438, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560352029,"sku":"50438","price":13800.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_bdcbc394-f172-434e-8525-b2d5107b709d.png?v=1780589894"},{"product_id":"schneider-electric-50439-closed-toroid-for-residual-current-protection-ia-80-mm-default-title","title":"Schneider Electric 50439 Vigirex Closed Toroid IA Ø80 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50439 is a Vigirex closed toroid with a 80 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50439 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric closed toroid (residual current sensor)s such as the 50439, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560384797,"sku":"50439","price":17390.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_18e79133-b5d6-42dd-a39e-3187bcd63bf7.jpg?v=1791710905"},{"product_id":"schneider-electric-50440-closed-toroid-for-residual-current-protection-ma-120-mm-default-title","title":"Schneider Electric 50440 Vigirex Closed Toroid MA Ø120 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50440 is a Vigirex closed toroid with a 120 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50440 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 50440 from Spark Egypt and receive an original closed toroid (residual current sensor) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560450333,"sku":"50440","price":22930.01,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_f1fe5dce-2256-4fbe-8c19-8ee49a96be19.png?v=1780589977"},{"product_id":"schneider-50441-vigirex-closed-toroid-sa200-200mm","title":"Schneider Electric 50441 Vigirex Closed Toroid SA200 Ø200 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50441 is a Vigirex closed toroid with a 200 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50441\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50441 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 50441 from Spark Egypt and receive an original closed toroid (residual current sensor) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560548637,"sku":"50441","price":33600.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_09cd67ac-083f-4639-ad73-c7be7032bcab.jpg?v=1791710607"},{"product_id":"schneider-56173-vigirex-rh99m-earth-leakage-relay-manual-reset","title":"Schneider Electric 56173 Vigirex RH99M Earth-Leakage Relay 0.03–30A 0–4.5s 240V Manual Reset","description":"\u003cp\u003eThe Schneider Electric 56173 is a Vigirex RH99M earth-leakage relay with adjustable sensitivity (0.03–30 A) and time delay (0–4.5 s), manual reset. Combined with a Vigirex toroid and the shunt trip of an MCCB or ACB, it provides adjustable earth-leakage protection for large feeders where RCCBs are not available.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable sensitivity and time delay for selectivity\u003c\/li\u003e\n\u003cli\u003eFault and pre-alarm indication\u003c\/li\u003e\n\u003cli\u003eWorks with any breaker equipped with a shunt trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e56173\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH99M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eEarth-leakage protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.03 – 30 A adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0 – 4.5 s adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSupply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReset\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain incomers and large feeders\u003c\/li\u003e\n\u003cli\u003eIndustrial plants and hospitals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 56173 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric earth-leakage relays such as the 56173, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560679709,"sku":"56173","price":24930.43,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/PB100429_SE_369.jpg?v=1791710565"},{"product_id":"schneider-56193-vigirex-rh99m-earth-leakage-relay-auto-reset","title":"Schneider Electric 56193 Vigirex RH99M Earth-Leakage Relay 0.03–30A 0–4.5s 240V Automatic Reset","description":"\u003cp\u003eThe Schneider Electric 56193 is a Vigirex RH99M earth-leakage relay with adjustable sensitivity (0.03–30 A) and time delay (0–4.5 s), automatic reset. Combined with a Vigirex toroid and the shunt trip of an MCCB or ACB, it provides adjustable earth-leakage protection for large feeders where RCCBs are not available.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable sensitivity and time delay for selectivity\u003c\/li\u003e\n\u003cli\u003eFault and pre-alarm indication\u003c\/li\u003e\n\u003cli\u003eWorks with any breaker equipped with a shunt trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e56193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH99M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eEarth-leakage protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.03 – 30 A adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0 – 4.5 s adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSupply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReset\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain incomers and large feeders\u003c\/li\u003e\n\u003cli\u003eIndustrial plants and hospitals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 56193 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 56193 from Spark Egypt and receive an original earth-leakage relay with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560745245,"sku":"56193","price":24937.73,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/56193-25.jpg?v=1791710303"},{"product_id":"siemens-rcbo-1pn-10ka-30ma-5su9304-1kk","title":"Siemens 5SU9304-1KK RCBO 1P+N 16–40 A C-Curve 30mA 10 kA | Earth Leakage + MCB in One","description":"\u003cp\u003eThe Siemens 5SU9304-1KK is a 1P+N 16–40 A C-curve RCBO with 30 mA earth-leakage sensitivity and 10 kA breaking capacity. It combines a miniature circuit breaker and a residual current device in one module, protecting the circuit against overload, short circuit and dangerous earth-leakage currents, and saving space in the distribution board.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload, short-circuit and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity – protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003eIndividual protection per circuit – a fault trips only the affected circuit\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting and compact width\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e5SU9304-1KK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO (RCD + MCB in one device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16–40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61009-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent: 16A, 20A, 25A, 32A, 40A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eIndividual protection of air-conditioner and socket circuits\u003c\/li\u003e\n\u003cli\u003eVillas, apartments, clinics and offices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eChoose the RCBO rating according to the cable size of the circuit, as for an MCB, and use 30 mA sensitivity for socket and wet-area circuits. Using an RCBO per circuit avoids total blackout of the apartment when one appliance leaks.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between an RCBO and an RCCB?\u003c\/h3\u003e\u003cp\u003eAn RCCB only detects earth leakage; an RCBO adds overload and short-circuit protection, so it can replace an MCB + RCCB combination for a single circuit.\u003c\/p\u003e\u003ch3\u003eWhere is the Siemens 5SU9304-1KK typically installed?\u003c\/h3\u003e\u003cp\u003eOn circuits feeding water heaters, bathrooms, kitchens, outdoor sockets and air conditioners where both overcurrent and shock protection are needed.\u003c\/p\u003e\n\u003ch2\u003eBuy Siemens 5SU9304-1KK in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Siemens 5SU9304-1KK residual current breaker with overcurrent protection (RCBO) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"16A","offer_id":51320030527773,"sku":"5SU9304-1KK16","price":3441.75,"currency_code":"EGP","in_stock":false},{"title":"20A","offer_id":51320030560541,"sku":"5SU9304-1KK20","price":3536.25,"currency_code":"EGP","in_stock":true},{"title":"25A","offer_id":51320030593309,"sku":"5SU9304-1KK25","price":3687.0,"currency_code":"EGP","in_stock":false},{"title":"32A","offer_id":51320030626077,"sku":"5SU9304-1KK32","price":3816.75,"currency_code":"EGP","in_stock":false},{"title":"40A","offer_id":51320030658845,"sku":"5SU9304-1KK40","price":3924.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/02_10_2025_11_33_20_5SU9304_7KK10.jpg?v=1779461208"},{"product_id":"schneider-electric-acti9-ic60h-rcbo-1pn-10ka-30ma-a9d118xx","title":"Schneider Electric A9D118 Acti9 iC60H RCBO 1P+N 10A–40A C-Curve 30mA 10kA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D118 is an Acti9 iC60H RCBO rated 10A–40A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60H RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10A–40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D118 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D118 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9D118 residual current circuit breaker with overcurrent protection (RCBO) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"A9D11810 - 10A","offer_id":51320057856285,"sku":"A9D11810","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11816 - 16A","offer_id":51320057889053,"sku":"A9D11816","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11820 - 20A","offer_id":51320057921821,"sku":"A9D11820","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11825 - 25A","offer_id":51320057954589,"sku":"A9D11825","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11832 - 32A","offer_id":51320057987357,"sku":"A9D11832","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11840 - 40A","offer_id":51320058020125,"sku":"A9D11840","price":3650.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9D11810_iC60H-earthleakagecircuitbreaker-1P_N-Ccurve-10A-30mA-240V.jpg?v=1779461268"},{"product_id":"schneider-electric-a9d31610-acti9-idpn-n-vigi-rcbo-1p-n-10a-c-curve-30ma-type-ac","title":"Schneider Electric A9D31610 Acti9 iDPN N Vigi 1P+N 10A C-Curve 30mA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D31610 is an Acti9 iDPN N Vigi RCBO rated 10A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D31610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iDPN N Vigi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D31610 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D31610 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9D31610 from Spark Egypt and receive an original residual current circuit breaker with overcurrent protection (RCBO) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562973469,"sku":"A9D31610","price":3401.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/rn-image_picker_lib_temp_3c101176-6b5a-44bf-9747-b73aa95ba972.jpg?v=1791576386"},{"product_id":"schneider-electric-a9d31620-acti9-idpn-n-vigi-rcbo-1p-n-20a-c-curve-30ma-type-ac","title":"Schneider Electric A9D31620 Acti9 iDPN N Vigi 1P+N 20A C-Curve 30mA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D31620 is an Acti9 iDPN N Vigi RCBO rated 20A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D31620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iDPN N Vigi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D31620 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D31620 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9D31620 from Spark Egypt and receive an original residual current circuit breaker with overcurrent protection (RCBO) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563006237,"sku":"A9D31620","price":3401.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/rn-image_picker_lib_temp_3c101176-6b5a-44bf-9747-b73aa95ba972.jpg?v=1791576386"},{"product_id":"schneider-electric-a9d61820-acti9-ic60n-earth-leakage-circuit-breaker-1p-n-20a-30ma","title":"Schneider Electric A9D61820 Acti9 iC60N RCBO 1P+N 20A C-Curve 30mA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D61820 is an Acti9 iC60N RCBO RCBO rated 20A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D61820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D61820 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D61820 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9D61820 from Spark Egypt and receive an original residual current circuit breaker with overcurrent protection (RCBO) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563071773,"sku":"A9D61820","price":3255.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_3be102e4-d4af-429b-a6d1-d2ff639ac9f5.jpg?v=1791709491"},{"product_id":"schneider-electric-a9r10225-acti-9-iid-rccb-2p-25a-10ma-type-ac-default-title","title":"Schneider Electric A9R10225 Acti9 iID RCCB 2P 25A 10mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R10225 is a 2-pole, 25A, 10 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing additional protection of people in wet areas and for sensitive circuits.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e10 mA sensitivity for additional protection of people in wet areas and for sensitive circuits\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R10225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R10225 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R10225 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric residual current circuit breaker (RCCB)s such as the A9R10225, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571558685,"sku":"A9R10225","price":4803.78,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/a9r10225-1_1.jpg?v=1791709433"},{"product_id":"schneider-electric-a9r11291-acti-9-iid-rccb-2p-100a-30ma-type-ac-default-title","title":"Schneider Electric A9R11291 Acti9 iID RCCB 2P 100A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R11291 is a 2-pole, 100A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R11291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R11291 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R11291 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R11291 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571591453,"sku":"A9R11291","price":6704.27,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/pb104472_1500-2-600x600_jpg.webp?v=1781987043"},{"product_id":"schneider-electric-a9r11480-acti-9-iid-rccb-4p-80a-30ma-type-ac-default-title","title":"Schneider Electric A9R11480 Acti9 iID RCCB 4P 80A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R11480 is a 4-pole, 80A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R11480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R11480 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R11480 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9R11480 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571656989,"sku":"A9R11480","price":7531.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/PB104473_IoP-Default_web-1_jpg.webp?v=1781969137"},{"product_id":"schneider-electric-a9r11491-acti-9-iid-rccb-4p-100a-30ma-type-ac-default-title","title":"Schneider Electric A9R11491 Acti9 iID RCCB 4P 100A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R11491 is a 4-pole, 100A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R11491\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R11491 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R11491 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R11491 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571689757,"sku":"A9R11491","price":8155.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/PB104473_IoP-Default_web-1_jpg.webp?v=1781969137"},{"product_id":"schneider-electric-a9r14480-acti-9-iid-rccb-4p-80a-300ma-type-ac-default-title","title":"Schneider Electric A9R14480 Acti9 iID RCCB 4P 80A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R14480 is a 4-pole, 80A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R14480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R14480 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R14480 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric residual current circuit breaker (RCCB)s such as the A9R14480, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571788061,"sku":"A9R14480","price":5921.34,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/pb104473_1500.jpg?v=1791709313"},{"product_id":"schneider-electric-a9r14491-acti-9-iid-rccb-4p-100a-300ma-type-ac-default-title","title":"Schneider Electric A9R14491 Acti9 iID RCCB 4P 100A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R14491 is a 4-pole, 100A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R14491\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R14491 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R14491 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R14491 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571820829,"sku":"A9R14491","price":7096.81,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_79598524-620e-4770-abf1-f0333d206abe.jpg?v=1791709251"},{"product_id":"schneider-electric-a9r41225-acti-9-iid-rccb-2p-25a-30ma-type-ac-default-title","title":"Schneider Electric A9R41225 Acti9 iID RCCB 2P 25A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R41225 is a 2-pole, 25A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R41225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R41225 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R41225 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9R41225 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571853597,"sku":"A9R41225","price":3821.36,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9R41225.jpg?v=1783466452"},{"product_id":"schneider-electric-a9r41240-acti-9-iid-rccb-2p-40a-30ma-type-ac-default-title","title":"Schneider Electric A9R41240 Acti9 iID RCCB 2P 40A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R41240 is a 2-pole, 40A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R41240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R41240 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R41240 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9R41240 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571886365,"sku":"A9R41240","price":4211.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9R41225.jpg?v=1783466452"},{"product_id":"schneider-electric-a9r41263-acti-9-iid-rccb-2p-63a-30ma-type-ac-default-title","title":"Schneider Electric A9R41263 Acti9 iID RCCB 2P 63A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R41263 is a 2-pole, 63A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R41263\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R41263 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R41263 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9R41263 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571919133,"sku":"A9R41263","price":4729.78,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9R41225.jpg?v=1783466452"},{"product_id":"schneider-electric-a9r41425-acti-9-iid-rccb-4p-25a-30ma-type-ac-default-title","title":"Schneider Electric A9R41425 Acti9 iID RCCB 4P 25A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R41425 is a 4-pole, 25A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R41425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R41425 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R41425 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R41425 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263571951901,"sku":"A9R41425","price":5081.56,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/a9r41440-2.jpg?v=1783466928"},{"product_id":"schneider-electric-a9r41440-acti-9-iid-rccb-4p-40a-30ma-type-ac-default-title","title":"Schneider Electric A9R41440 Acti9 iID RCCB 4P 40A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R41440 is a 4-pole, 40A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R41440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R41440 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R41440 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R41440 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572017437,"sku":"A9R41440","price":5482.68,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/a9r41440-2.jpg?v=1783466928"},{"product_id":"schneider-electric-a9r41463-acti-9-iid-rccb-4p-63a-30ma-type-ac-default-title","title":"Schneider Electric A9R41463 Acti9 iID RCCB 4P 63A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R41463 is a 4-pole, 63A, 30 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R41463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R41463 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R41463 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9R41463 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572082973,"sku":"A9R41463","price":6387.88,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/a9r41440-2.jpg?v=1783466928"},{"product_id":"schneider-electric-a9r44225-acti-9-iid-rccb-2p-25a-300ma-type-ac-default-title","title":"Schneider Electric A9R44225 Acti9 iID RCCB 2P 25A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R44225 is a 2-pole, 25A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R44225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R44225 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R44225 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R44225 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572115741,"sku":"A9R44225","price":2572.75,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/pb104472_1500-7-1024x1024_jpg.webp?v=1782026997"},{"product_id":"schneider-electric-a9r44240-acti-9-iid-rccb-2p-40a-300ma-type-ac-default-title","title":"Schneider Electric A9R44240 Acti9 iID RCCB 2P 40A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R44240 is a 2-pole, 40A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R44240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R44240 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R44240 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R44240 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572148509,"sku":"A9R44240","price":3051.55,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/pb104472_1500-7-1024x1024_jpg.webp?v=1782026997"},{"product_id":"schneider-electric-a9r44263-acti-9-iid-rccb-2p-63a-300ma-type-ac-default-title","title":"Schneider Electric A9R44263 Acti9 iID RCCB 2P 63A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R44263 is a 2-pole, 63A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R44263\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R44263 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R44263 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9R44263 from Spark Egypt and receive an original residual current circuit breaker (RCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572377885,"sku":"A9R44263","price":3642.25,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/pb104472_1500-2-600x600_jpg.webp?v=1781987043"},{"product_id":"schneider-electric-a9r44425-acti-9-iid-rccb-4p-25a-300ma-type-ac-default-title","title":"Schneider Electric A9R44425 Acti9 iID RCCB 4P 25A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R44425 is a 4-pole, 25A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R44425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R44425 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R44425 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9R44425 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572443421,"sku":"A9R44425","price":3701.24,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/pb104473_1500-7-600x600_jpg.webp?v=1781996035"},{"product_id":"schneider-electric-a9r44440-acti-9-iid-rccb-4p-40a-300ma-type-ac-default-title","title":"Schneider Electric A9R44440 Acti9 iID RCCB 4P 40A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R44440 is a 4-pole, 40A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R44440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R44440 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R44440 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric residual current circuit breaker (RCCB)s such as the A9R44440, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572508957,"sku":"A9R44440","price":3790.58,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/pb104473_1500-7-600x600_jpg.webp?v=1781996035"},{"product_id":"schneider-electric-a9r44463-acti-9-iid-rccb-4p-63a-300ma-type-ac-default-title","title":"Schneider Electric A9R44463 Acti9 iID RCCB 4P 63A 300mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9R44463 is a 4-pole, 63A, 300 mA type AC residual current circuit breaker (RCCB) from the Acti9 iID range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing fire protection and protection of installations against earth-fault currents.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e300 mA sensitivity for fire protection and protection of installations against earth-fault currents\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9R44463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the A9R44463 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9R44463 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9R44463 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263572574493,"sku":"A9R44463","price":4522.25,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/PB104473_IoP-Default_web-1_jpg.webp?v=1781969137"},{"product_id":"himel-hdb3vr-rccb-30ma-6ka","title":"Himel HDB3VR RCCB 2P 25–63 A 30mA Type AC 6kA | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Himel HDB3VR is a 2P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHimel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHDB3VR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eShort-circuit withstand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent: 2P - 25A, 2P - 40A, 2P - 63A, 4P - 25A, 4P - 40A, 4P - 63A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Himel HDB3VR protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Himel HDB3VR in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Himel HDB3VR residual current circuit breaker (RCCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"Himel","offers":[{"title":"2P - 25A","offer_id":51320823087389,"sku":"HDB3VR225SC","price":1740.0,"currency_code":"EGP","in_stock":true},{"title":"2P - 40A","offer_id":51320823120157,"sku":"HDB3VR240SC","price":1740.0,"currency_code":"EGP","in_stock":true},{"title":"2P - 63A","offer_id":51320823152925,"sku":"HDB3VR263SC","price":1930.0,"currency_code":"EGP","in_stock":true},{"title":"4P - 25A","offer_id":51320823185693,"sku":"HDB3VR425SC","price":2600.0,"currency_code":"EGP","in_stock":true},{"title":"4P - 40A","offer_id":51320823218461,"sku":"HDB3VR440SC","price":2600.0,"currency_code":"EGP","in_stock":true},{"title":"4P - 63A","offer_id":51320823251229,"sku":"HDB3VR463SC","price":2831.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/Himel-2-Pole-Residual-Current-Operated-Circuit-Breaker-1-3_938x938_8ebb2f9d-1587-4ef7-a955-627b455ec057.webp?v=1779474143"},{"product_id":"schneider-electric-resi9-rccb-r9r51225-r9r51463","title":"Schneider Electric R9R5 Resi9 RCCB 2P 25A–63A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric R9R5 is a 2-pole, 25A–63A, 30 mA type AC residual current circuit breaker (RCCB) from the Resi9 range. It continuously compares the outgoing and returning current and disconnects the circuit when an earth-leakage current is detected, providing protection of people against electric shock (direct and indirect contact).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock (direct and indirect contact)\u003c\/li\u003e\n\u003cli\u003e2-pole version for single-phase installations\u003c\/li\u003e\n\u003cli\u003eTest button to check correct operation periodically\u003c\/li\u003e\n\u003cli\u003eTrip indication and positive contact indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, combines with MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eMust be used together with MCBs or upstream circuit breakers for short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eR9R5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResi9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25A–63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, hospitals and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 300 mA for fire protection at the main incomer, and choose the rated current equal to or higher than the upstream MCB rating. A 2-pole RCCB is used for single-phase supplies; a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the R9R5 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only; it must be protected by an MCB or circuit breaker of equal or lower rating for overload and short-circuit protection.\u003c\/p\u003e\u003ch3\u003eWhy does my RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eNuisance tripping is usually caused by real insulation faults, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB provides earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider R9R5 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric R9R5 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"2P \/ 25A","offer_id":51297202929949,"sku":"R9R51225","price":2349.72,"currency_code":"EGP","in_stock":true},{"title":"2P \/ 40A","offer_id":51297331314973,"sku":"R9R51240","price":2580.46,"currency_code":"EGP","in_stock":true},{"title":"2P \/ 63A","offer_id":51297331380509,"sku":"R9R51263","price":2875.0,"currency_code":"EGP","in_stock":true},{"title":"4P \/ 25A","offer_id":51297202962717,"sku":"R9R51425","price":3144.91,"currency_code":"EGP","in_stock":true},{"title":"4P \/ 40A","offer_id":51297331347741,"sku":"R9R51440","price":3469.42,"currency_code":"EGP","in_stock":true},{"title":"4P \/ 63A","offer_id":51297331413277,"sku":"R9R51463","price":3856.45,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/R9R51225___Schneider_Electric_Resi9_RCCB_2P_25A_30mA_Earth_Leakage_Protection_230V.png?v=1778964787"},{"product_id":"siemens-5su-rcbo-1pn-30ma-10ka","title":"Siemens 5SU RCBO 1P+N 16–40 A C-Curve 30mA 10 kA | Earth Leakage + MCB in One","description":"\u003cp\u003eThe Siemens 5SU is a 1P+N 16–40 A C-curve RCBO with 30 mA earth-leakage sensitivity and 10 kA breaking capacity. It combines a miniature circuit breaker and a residual current device in one module, protecting the circuit against overload, short circuit and dangerous earth-leakage currents, and saving space in the distribution board.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload, short-circuit and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity – protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003eIndividual protection per circuit – a fault trips only the affected circuit\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting and compact width\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e5SU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO (RCD + MCB in one device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16–40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61009-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent Rating: 16A, 20A, 25A, 32A, 40A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eIndividual protection of air-conditioner and socket circuits\u003c\/li\u003e\n\u003cli\u003eVillas, apartments, clinics and offices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eChoose the RCBO rating according to the cable size of the circuit, as for an MCB, and use 30 mA sensitivity for socket and wet-area circuits. Using an RCBO per circuit avoids total blackout of the apartment when one appliance leaks.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between an RCBO and an RCCB?\u003c\/h3\u003e\u003cp\u003eAn RCCB only detects earth leakage; an RCBO adds overload and short-circuit protection, so it can replace an MCB + RCCB combination for a single circuit.\u003c\/p\u003e\u003ch3\u003eWhere is the Siemens 5SU typically installed?\u003c\/h3\u003e\u003cp\u003eOn circuits feeding water heaters, bathrooms, kitchens, outdoor sockets and air conditioners where both overcurrent and shock protection are needed.\u003c\/p\u003e\n\u003ch2\u003eBuy Siemens 5SU in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Siemens products such as the 5SU residual current breaker with overcurrent protection (RCBO), serving contractors, OEMs, panel builders, facility managers and home owners with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our sales team to confirm selection, compatible accessories and project pricing.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"16A","offer_id":51559437861149,"sku":"5SU9304-1KK16","price":3441.75,"currency_code":"EGP","in_stock":true},{"title":"20A","offer_id":51559437893917,"sku":"5SU9304-1KK20","price":3536.25,"currency_code":"EGP","in_stock":true},{"title":"25A","offer_id":51559437926685,"sku":"5SU9304-1KK25","price":3687.0,"currency_code":"EGP","in_stock":true},{"title":"32A","offer_id":51559437959453,"sku":"5SU9304-1KK32","price":3816.75,"currency_code":"EGP","in_stock":true},{"title":"40A","offer_id":51559437992221,"sku":"5SU9304-1KK40","price":3924.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/G_I202_XX_53185i_399458e4-b859-47fd-8dc2-e1cffa6229a7.jpg?v=1780096116"},{"product_id":"siemens-5sv-rccb-30ma-6ka","title":"Siemens 5SV RCCB 2P 25–63 A 30mA Type AC 6kA | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Siemens 5SV is a 2P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e5SV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eShort-circuit withstand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent and Poles: 25A \/ 2P, 40A \/ 2P, 63A \/ 2P, 25A \/ 4P, 40A \/ 4P, 63A \/ 4P.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Siemens 5SV protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Siemens 5SV in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Siemens 5SV residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants, retailers and maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"25A \/ 2P","offer_id":51559994556701,"sku":"5SV4312-0","price":2925.0,"currency_code":"EGP","in_stock":true},{"title":"40A \/ 2P","offer_id":51559994589469,"sku":"5SV4314-0","price":3112.5,"currency_code":"EGP","in_stock":true},{"title":"63A \/ 2P","offer_id":51559994622237,"sku":"5SV4316-0","price":4725.0,"currency_code":"EGP","in_stock":true},{"title":"25A \/ 4P","offer_id":51559994655005,"sku":"5SV4342-0","price":3075.0,"currency_code":"EGP","in_stock":true},{"title":"40A \/ 4P","offer_id":51559994687773,"sku":"5SV4344-0","price":3375.0,"currency_code":"EGP","in_stock":true},{"title":"63A \/ 4P","offer_id":51559994720541,"sku":"5SV4346-0","price":5100.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/G_I202_XX_87184i_8d8b5678-3b95-436a-8eaa-6b24c323b50d.jpg?v=1780096840"},{"product_id":"siemens-5sv-rccb-30ma-10ka","title":"Siemens 5SV RCCB 2P 25–63 A 30mA Type AC 10kA | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Siemens 5SV is a 2P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e5SV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eShort-circuit withstand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent and Poles: 25A \/ 2P, 40A \/ 2P, 63A \/ 2P, 25A \/ 4P, 40A \/ 4P, 63A \/ 4P.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Siemens 5SV protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Siemens 5SV in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Siemens products such as the 5SV residual current circuit breaker (RCCB), serving contractors, OEMs, panel builders, facility managers and home owners with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our sales team to confirm selection, compatible accessories and project pricing.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"25A \/ 2P","offer_id":51560071561501,"sku":"5SV5312-0","price":1923.75,"currency_code":"EGP","in_stock":true},{"title":"40A \/ 2P","offer_id":51560071594269,"sku":"5SV5314-0","price":2126.25,"currency_code":"EGP","in_stock":true},{"title":"63A \/ 2P","offer_id":51560071627037,"sku":"5SV5316-0","price":3442.5,"currency_code":"EGP","in_stock":true},{"title":"25A \/ 4P","offer_id":51560071659805,"sku":"5SV5342-0","price":2430.0,"currency_code":"EGP","in_stock":true},{"title":"40A \/ 4P","offer_id":51560071692573,"sku":"5SV5344-0","price":2531.25,"currency_code":"EGP","in_stock":true},{"title":"63A \/ 4P","offer_id":51560071725341,"sku":"5SV5346-0","price":4455.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/G_I202_XX_57879i_04878512-dbeb-47c5-ae82-ad245a2b8f2e.jpg?v=1780096928"},{"product_id":"hyundai-hrc-rccb-2-pole-30ma","title":"Hyundai HRC RCCB 2P 25–63 A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Hyundai HRC is a 2P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHyundai\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHRC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eRated Current: 25 A, 40 A, 63 A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Hyundai HRC protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Hyundai HRC in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Hyundai products such as the HRC residual current circuit breaker (RCCB), serving contractors, OEMs, panel builders, facility managers and home owners with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our sales team to confirm selection, compatible accessories and project pricing.\u003c\/p\u003e","brand":"Hyundai","offers":[{"title":"25 A","offer_id":51592518107421,"sku":"HRC63S2PG4S0000C00025G","price":790.0,"currency_code":"EGP","in_stock":true},{"title":"40 A","offer_id":51592518140189,"sku":"HRC63S2PG4S0000C00040G","price":790.0,"currency_code":"EGP","in_stock":true},{"title":"63 A","offer_id":51592518172957,"sku":"HRC63S2PG4S0000C00063G","price":790.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/Diferencial-Hyundai-HRC-63S-HRC63S-F2PG4040-1000x1000.webp?v=1784387813"},{"product_id":"hyundai-hrc-rccb-4-pole-30ma","title":"Hyundai HRC RCCB 4P 25–63 A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Hyundai HRC is a 4P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e4P version for three-phase + neutral supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHyundai\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHRC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eRated Current: 25 A, 40 A, 63 A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Hyundai HRC protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Hyundai HRC in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Hyundai products such as the HRC residual current circuit breaker (RCCB), serving contractors, OEMs, panel builders, facility managers and home owners with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our sales team to confirm selection, compatible accessories and project pricing.\u003c\/p\u003e","brand":"Hyundai","offers":[{"title":"25 A","offer_id":51592518205725,"sku":"HRC63S4PG4S0000C00025G","price":1070.0,"currency_code":"EGP","in_stock":true},{"title":"40 A","offer_id":51592518238493,"sku":"HRC63S4PG4S0000C00040G","price":1070.0,"currency_code":"EGP","in_stock":true},{"title":"63 A","offer_id":51592518271261,"sku":"HRC63S4PG4S0000C00063G","price":1070.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/hrc100s-4p-8586_png.webp?v=1784389568"},{"product_id":"hager-adc-rcbo-1pn-6ka-c-curve-30ma-type-ac","title":"Hager ADC RCBO 1P+N 10–40 A C-Curve 30mA 6 kA | Earth Leakage + MCB in One","description":"\u003cp\u003eThe Hager ADC is a 1P+N 10–40 A C-curve RCBO with 30 mA earth-leakage sensitivity and 6 kA breaking capacity. It combines a miniature circuit breaker and a residual current device in one module, protecting the circuit against overload, short circuit and dangerous earth-leakage currents, and saving space in the distribution board.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload, short-circuit and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity – protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003eIndividual protection per circuit – a fault trips only the affected circuit\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting and compact width\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO (RCD + MCB in one device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10–40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61009-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent Rating: 10 A, 16 A, 20 A, 25 A, 32 A, 40 A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eIndividual protection of air-conditioner and socket circuits\u003c\/li\u003e\n\u003cli\u003eVillas, apartments, clinics and offices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eChoose the RCBO rating according to the cable size of the circuit, as for an MCB, and use 30 mA sensitivity for socket and wet-area circuits. Using an RCBO per circuit avoids total blackout of the apartment when one appliance leaks.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between an RCBO and an RCCB?\u003c\/h3\u003e\u003cp\u003eAn RCCB only detects earth leakage; an RCBO adds overload and short-circuit protection, so it can replace an MCB + RCCB combination for a single circuit.\u003c\/p\u003e\u003ch3\u003eWhere is the Hager ADC typically installed?\u003c\/h3\u003e\u003cp\u003eOn circuits feeding water heaters, bathrooms, kitchens, outdoor sockets and air conditioners where both overcurrent and shock protection are needed.\u003c\/p\u003e\n\u003ch2\u003eBuy Hager ADC in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Hager ADC residual current breaker with overcurrent protection (RCBO) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"Hager","offers":[{"title":"10 A","offer_id":51594758062365,"sku":"ADC210Z","price":3753.0,"currency_code":"EGP","in_stock":true},{"title":"16 A","offer_id":51594758095133,"sku":"ADC216Z","price":3753.0,"currency_code":"EGP","in_stock":false},{"title":"20 A","offer_id":51594758127901,"sku":"ADC220Z","price":3753.0,"currency_code":"EGP","in_stock":false},{"title":"25 A","offer_id":51594758160669,"sku":"ADC225Z","price":3753.0,"currency_code":"EGP","in_stock":false},{"title":"32 A","offer_id":51594758193437,"sku":"ADC232Z","price":3753.0,"currency_code":"EGP","in_stock":false},{"title":"40 A","offer_id":51594758226205,"sku":"ADC240Z","price":3753.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/ADC206Z.webp?v=1780140999"},{"product_id":"hager-adc-rcbo-1pn-10ka-c-curve-30ma-type-ac","title":"Hager ADC RCBO 1P+N 10–40 A C-Curve 30mA 10 kA | Earth Leakage + MCB in One","description":"\u003cp\u003eThe Hager ADC is a 1P+N 10–40 A C-curve RCBO with 30 mA earth-leakage sensitivity and 10 kA breaking capacity. It combines a miniature circuit breaker and a residual current device in one module, protecting the circuit against overload, short circuit and dangerous earth-leakage currents, and saving space in the distribution board.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload, short-circuit and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity – protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003eIndividual protection per circuit – a fault trips only the affected circuit\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting and compact width\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO (RCD + MCB in one device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10–40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61009-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent Rating: 10 A, 16 A, 20 A, 25 A, 32 A, 40 A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eIndividual protection of air-conditioner and socket circuits\u003c\/li\u003e\n\u003cli\u003eVillas, apartments, clinics and offices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eChoose the RCBO rating according to the cable size of the circuit, as for an MCB, and use 30 mA sensitivity for socket and wet-area circuits. Using an RCBO per circuit avoids total blackout of the apartment when one appliance leaks.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between an RCBO and an RCCB?\u003c\/h3\u003e\u003cp\u003eAn RCCB only detects earth leakage; an RCBO adds overload and short-circuit protection, so it can replace an MCB + RCCB combination for a single circuit.\u003c\/p\u003e\u003ch3\u003eWhere is the Hager ADC typically installed?\u003c\/h3\u003e\u003cp\u003eOn circuits feeding water heaters, bathrooms, kitchens, outdoor sockets and air conditioners where both overcurrent and shock protection are needed.\u003c\/p\u003e\n\u003ch2\u003eBuy Hager ADC in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Hager ADC residual current breaker with overcurrent protection (RCBO) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"Hager","offers":[{"title":"10 A","offer_id":51594826481949,"sku":"ADC285Y","price":3998.0,"currency_code":"EGP","in_stock":false},{"title":"16 A","offer_id":51594826514717,"sku":"ADC287Y","price":3998.0,"currency_code":"EGP","in_stock":false},{"title":"20 A","offer_id":51594826547485,"sku":"ADC288Y","price":3998.0,"currency_code":"EGP","in_stock":false},{"title":"25 A","offer_id":51594826580253,"sku":"ADC289Y","price":3998.0,"currency_code":"EGP","in_stock":false},{"title":"32 A","offer_id":51594826613021,"sku":"ADC290Y","price":3998.0,"currency_code":"EGP","in_stock":false},{"title":"40 A","offer_id":51594826645789,"sku":"ADC291Y","price":3998.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/ADC284Y.webp?v=1780141085"},{"product_id":"hager-cd-rccb-2p-30ma-type-ac","title":"Hager CD RCCB 2P 25–63 A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Hager CD is a 2P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent Rating: 25 A, 40 A, 63 A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Hager CD protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Hager CD in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Hager CD residual current circuit breaker (RCCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"Hager","offers":[{"title":"25 A","offer_id":51595293524253,"sku":"CD226J","price":2185.0,"currency_code":"EGP","in_stock":true},{"title":"40 A","offer_id":51595293557021,"sku":"CD241J","price":2289.6,"currency_code":"EGP","in_stock":true},{"title":"63 A","offer_id":51595293589789,"sku":"CD264J","price":2629.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/CD226J.webp?v=1780141663"},{"product_id":"hager-cd-rccb-4p-30ma-type-ac","title":"Hager CD RCCB 4P 25–100 A 30mA Type AC | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThe Hager CD is a 4P, 25–100 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e4P version for three-phase + neutral supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent Rating: 25 A, 40 A, 63 A, 100 A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Hager CD protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Hager CD in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Hager CD residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants, retailers and maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Hager","offers":[{"title":"25 A","offer_id":51595453497629,"sku":"CD426J","price":2932.0,"currency_code":"EGP","in_stock":true},{"title":"40 A","offer_id":51595453530397,"sku":"CD441J","price":3072.0,"currency_code":"EGP","in_stock":true},{"title":"63 A","offer_id":51595453563165,"sku":"CD464J","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"100 A","offer_id":51595453595933,"sku":"CD485Z","price":6226.4,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/CD426J.webp?v=1780141851"},{"product_id":"beta-electric-2p-30ma-80a-frame-rccb","title":"Beta Electric RCCB 2P 25–63 A 30mA Type AC 6kA | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThis Beta Electric model is a 2P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBeta Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eShort-circuit withstand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent Rating: 25A, 40A, 63A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Beta product protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Beta RCCB in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Beta Electric products such as the residual current circuit breaker (RCCB), serving contractors, OEMs, panel builders, facility managers and home owners with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our sales team to confirm selection, compatible accessories and project pricing.\u003c\/p\u003e","brand":"Beta Electric","offers":[{"title":"25A","offer_id":51733821784349,"sku":"BE.2RC080C025L","price":664.2,"currency_code":"EGP","in_stock":true},{"title":"40A","offer_id":51733821817117,"sku":"BE.2RC080C040L","price":664.2,"currency_code":"EGP","in_stock":true},{"title":"63A","offer_id":51733821849885,"sku":"BE.2RC080C063L","price":810.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/23a50b6e-e233-4f58-9ec5-cbc7311b7cb0.png?v=1784579160"},{"product_id":"beta-electric-4p-30ma-100a-frame-rccb","title":"Beta Electric RCCB 4P 25–63 A 30mA Type AC 6kA | Earth Leakage Circuit Breaker","description":"\u003cp\u003eThis Beta Electric model is a 4P, 25–63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e4P version for three-phase + neutral supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBeta Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25–63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eShort-circuit withstand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent Rating: 25A, 40A, 63A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the Beta product protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy Beta RCCB in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Beta Electric residual current circuit breaker (RCCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"Beta Electric","offers":[{"title":"25A","offer_id":51733947253021,"sku":"BE.4RC100C025L","price":993.6,"currency_code":"EGP","in_stock":true},{"title":"40A","offer_id":51733947285789,"sku":"BE.4RC100C040L","price":993.6,"currency_code":"EGP","in_stock":true},{"title":"63A","offer_id":51733947318557,"sku":"BE.4RC100C063L","price":1096.2,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/a2024403-c7da-40f2-9fa4-30b49f87f5c6.png?v=1784579892"},{"product_id":"abb-2csf202006r1250-fh202-ac-25-0-03-25-a-2p","title":"ABB FH202 AC-25\/0.03 RCCB 2P 25 A 30mA Type AC | 2CSF202006R1250","description":"\u003cp\u003eThe ABB FH202 AC-25\/0.03 (2CSF202006R1250) is a 2P, 25 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH202 AC-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH200 RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CSF202006R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the ABB FH202 AC-25\/0.03 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB FH202 AC-25\/0.03 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the ABB FH202 AC-25\/0.03 residual current circuit breaker (RCCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945711927581,"sku":"2CSF202006R1250","price":2196.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2csf202006r1250.png?v=1782986096"},{"product_id":"abb-2csf202006r1400-fh202-ac-40-0-03-40-a-2p","title":"ABB FH202 AC-40\/0.03 RCCB 2P 40 A 30mA Type AC | 2CSF202006R1400","description":"\u003cp\u003eThe ABB FH202 AC-40\/0.03 (2CSF202006R1400) is a 2P, 40 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH202 AC-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH200 RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CSF202006R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the ABB FH202 AC-40\/0.03 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB FH202 AC-40\/0.03 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original ABB products such as the FH202 AC-40\/0.03 residual current circuit breaker (RCCB), serving contractors, OEMs, panel builders, facility managers and home owners with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our sales team to confirm selection, compatible accessories and project pricing.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945711960349,"sku":"2CSF202006R1400","price":2416.45,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2csf202006r1400.png?v=1782986097"},{"product_id":"abb-2csf202006r1630-fh202-ac-63-0-03-63-a-2p","title":"ABB FH202 AC-63\/0.03 RCCB 2P 63 A 30mA Type AC | 2CSF202006R1630","description":"\u003cp\u003eThe ABB FH202 AC-63\/0.03 (2CSF202006R1630) is a 2P, 63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e2P version for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH202 AC-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH200 RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CSF202006R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the ABB FH202 AC-63\/0.03 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB FH202 AC-63\/0.03 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original ABB FH202 AC-63\/0.03 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants, retailers and maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945711993117,"sku":"2CSF202006R1630","price":2695.5,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2csf202006r1630.png?v=1782986098"},{"product_id":"abb-2csf204006r1250-fh204-ac-25-0-03-25-a-4p","title":"ABB FH204 AC-25\/0.03 RCCB 4P 25 A 30mA Type AC | 2CSF204006R1250","description":"\u003cp\u003eThe ABB FH204 AC-25\/0.03 (2CSF204006R1250) is a 4P, 25 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e4P version for three-phase + neutral supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH204 AC-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH200 RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CSF204006R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the ABB FH204 AC-25\/0.03 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB FH204 AC-25\/0.03 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original ABB FH204 AC-25\/0.03 residual current circuit breaker (RCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants, retailers and maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945712025885,"sku":"2CSF204006R1250","price":2947.5,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2csf204006r1250.png?v=1782986100"},{"product_id":"abb-2csf204006r1400-fh204-ac-40-0-03-40-a-4p","title":"ABB FH204 AC-40\/0.03 RCCB 4P 40 A 30mA Type AC | 2CSF204006R1400","description":"\u003cp\u003eThe ABB FH204 AC-40\/0.03 (2CSF204006R1400) is a 4P, 40 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e4P version for three-phase + neutral supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH204 AC-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH200 RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CSF204006R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the ABB FH204 AC-40\/0.03 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB FH204 AC-40\/0.03 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the ABB FH204 AC-40\/0.03 residual current circuit breaker (RCCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945712058653,"sku":"2CSF204006R1400","price":3245.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2csf204006r1400.png?v=1782986101"},{"product_id":"abb-2csf204006r1630-fh204-ac-63-0-03-63-a-4p","title":"ABB FH204 AC-63\/0.03 RCCB 4P 63 A 30mA Type AC | 2CSF204006R1630","description":"\u003cp\u003eThe ABB FH204 AC-63\/0.03 (2CSF204006R1630) is a 4P, 63 A, 30 mA type AC residual current circuit breaker. It constantly compares the outgoing and returning current and disconnects the supply as soon as an earth-leakage current is detected, providing protection of people against electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30 mA sensitivity for protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003e4P version for three-phase + neutral supplies\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking of correct operation\u003c\/li\u003e\n\u003cli\u003eTrip and contact-position indication\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting next to MCBs in the same board\u003c\/li\u003e\n\u003cli\u003eUse with an upstream MCB\/MCCB for overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH204 AC-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFH200 RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CSF204006R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eResidual current circuit breaker (RCCB \/ ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment and villa main distribution boards\u003c\/li\u003e\n\u003cli\u003eBathrooms, kitchens, outdoor sockets and wet areas\u003c\/li\u003e\n\u003cli\u003eOffices, schools, clinics and commercial buildings\u003c\/li\u003e\n\u003cli\u003eWater heater, pump and swimming-pool circuits\u003c\/li\u003e\n\u003cli\u003eCompliance with Egyptian electrical code requirements for earth-leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eUse 30 mA for protection of people, 100–300 mA for fire and installation protection at the main incomer, and choose a rated current equal to or higher than the upstream breaker. Use a 2-pole RCCB for single-phase supplies and a 4-pole RCCB for three-phase supplies with neutral.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eDoes the ABB FH204 AC-63\/0.03 protect against short circuits?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB detects earth leakage only and must be protected by an MCB or MCCB of equal or lower rating.\u003c\/p\u003e\u003ch3\u003eWhy does an RCCB trip frequently?\u003c\/h3\u003e\u003cp\u003eUsually because of a real insulation fault, moisture in outlets or appliances with high leakage such as old water heaters. Test each circuit separately to locate the fault.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between an RCCB and an RCBO?\u003c\/h3\u003e\u003cp\u003eAn RCCB gives earth-leakage protection only, while an RCBO combines earth-leakage and overcurrent (MCB) protection in one device.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB FH204 AC-63\/0.03 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the ABB FH204 AC-63\/0.03 residual current circuit breaker (RCCB) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945712288029,"sku":"2CSF204006R1630","price":3614.8,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2csf204006r1630.png?v=1782986129"},{"product_id":"abb-2csr255053r1164-dse201-c16-ac30-n-black-16-a-1p-plus-n","title":"ABB RCBO 1P+N 16 A C-Curve 30mA 6 kA | 2CSR255053R1164","description":"\u003cp\u003eThis ABB model is a 1P+N 16 A C-curve RCBO with 30 mA earth-leakage sensitivity and 6 kA breaking capacity. It combines a miniature circuit breaker and a residual current device in one module, protecting the circuit against overload, short circuit and dangerous earth-leakage currents, and saving space in the distribution board.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload, short-circuit and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity – protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003eIndividual protection per circuit – a fault trips only the affected circuit\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting and compact width\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eDSE201 RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eABB order code\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2CSR255053R1164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO (RCD + MCB in one device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61009-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eIndividual protection of air-conditioner and socket circuits\u003c\/li\u003e\n\u003cli\u003eVillas, apartments, clinics and offices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eChoose the RCBO rating according to the cable size of the circuit, as for an MCB, and use 30 mA sensitivity for socket and wet-area circuits. Using an RCBO per circuit avoids total blackout of the apartment when one appliance leaks.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between an RCBO and an RCCB?\u003c\/h3\u003e\u003cp\u003eAn RCCB only detects earth leakage; an RCBO adds overload and short-circuit protection, so it can replace an MCB + RCCB combination for a single circuit.\u003c\/p\u003e\u003ch3\u003eWhere is the ABB product typically installed?\u003c\/h3\u003e\u003cp\u003eOn circuits feeding water heaters, bathrooms, kitchens, outdoor sockets and air conditioners where both overcurrent and shock protection are needed.\u003c\/p\u003e\n\u003ch2\u003eBuy ABB RCBO in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the ABB residual current breaker with overcurrent protection (RCBO) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Standard","offer_id":51945712320797,"sku":"2CSR255053R1164","price":2016.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/abb-2csr255053r1164.png?v=1782986129"}],"url":"https:\/\/www.spark-eshop.com\/collections\/category-rccb-rcbo-protection.oembed?page=4","provider":"Spark","version":"1.0","type":"link"}