{"title":"Category - Motor Circuit Breakers","description":null,"products":[{"product_id":"schneider-electric-3dm2-wrduwz-eocr-digital-motor-protection-relay-0-5-60a-100-240vac-dc","title":"Schneider Electric 3DM2-WRDUWZ EOCR-3DM2 Digital Motor Protection Relay 0.5–60 A 100–240V AC\/DC","description":"\u003cp\u003eThe Schneider Electric 3DM2-WRDUWZ is an EOCR-3DM2 electronic motor protection relay with a 0.5–60 A current range. Unlike bimetal overloads, it measures current electronically for accurate, repeatable protection of pumps, compressors and fans against overload, phase loss and locked rotor.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate electronic current measurement\u003c\/li\u003e\n\u003cli\u003eIndependent time settings for start and operation\u003c\/li\u003e\n\u003cli\u003eFault indication for fast troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3DM2-WRDUWZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eEOCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eElectronic overcurrent \/ motor protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCurrent range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.5–60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSupply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtections\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eOvercurrent, phase loss, locked rotor, undercurrent, unbalance, reverse phase (digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSubmersible and booster pumps\u003c\/li\u003e\n\u003cli\u003eCompressors and chillers\u003c\/li\u003e\n\u003cli\u003eFans and conveyors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 3DM2-WRDUWZ in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric electronic motor protection relays such as the 3DM2-WRDUWZ, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263558418717,"sku":"3DM2-WRDUWZ","price":15390.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_11b65d7a-0d30-4991-b4ab-02b09001d69a.jpg?v=1791711005"},{"product_id":"gv2l03-motor-circuit-breaker-tesys-gv2-3p-0-4-a-magnetic-rotary-handle-screw-clamp-terminals","title":"GV2L03 - Motor circuit breaker, TeSys GV2, 3P, 0.4 A, magnetic, rotary handle, screw clamp terminals","description":"","brand":"Spark","offers":[{"title":"Default Title","offer_id":51263589875997,"sku":null,"price":3693.04,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l03.jpg?v=1789732240"},{"product_id":"gv2l04-motor-circuit-breaker-tesys-gv2-3p-0-63-a-magnetic-rotary-handle-screw-clamp-ter","title":"Schneider Electric GV2L04 TeSys GV2 Motor Circuit Breaker 3P 0.63 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L04 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 0.63 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L04?\u003c\/h3\u003e\u003cp\u003eWith a 0.63 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L04 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2L04, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263589941533,"sku":null,"price":3693.04,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l04.jpg?v=1789732244"},{"product_id":"gv2l05-motor-circuit-breaker-tesys-gv2-3p-1-a-magnetic-rotary-handle-screw-clamp-termin","title":"Schneider Electric GV2L05 TeSys GV2 Motor Circuit Breaker 3P 1 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L05 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 1 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L05?\u003c\/h3\u003e\u003cp\u003eWith a 1 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L05 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2L05 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263589974301,"sku":null,"price":4041.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l05.jpg?v=1789732246"},{"product_id":"gv2l06-motor-circuit-breaker-tesys-gv2-3p-1-6-a-magnetic-rotary-handle-screw-clamp-term","title":"Schneider Electric GV2L06 TeSys GV2 Motor Circuit Breaker 3P 1.6 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L06 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 1.6 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L06?\u003c\/h3\u003e\u003cp\u003eWith a 1.6 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L06 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2L06, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590072605,"sku":null,"price":4041.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l06.jpg?v=1789732250"},{"product_id":"schneider-electric-gv2l07-tesys-gv2-motor-circuit-breaker-3p-2-5a-magnetic","title":"Schneider Electric GV2L07 TeSys GV2 Motor Circuit Breaker 3P 2.5 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L07 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 2.5 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L07?\u003c\/h3\u003e\u003cp\u003eWith a 2.5 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L07 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2L07 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590105373,"sku":"GV2L07","price":4041.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3.jpg?v=1791536561"},{"product_id":"schneider-electric-gv2l08-tesys-gv2-motor-circuit-breaker-3p-4a-magnetic","title":"Schneider Electric GV2L08 TeSys GV2 Motor Circuit Breaker 3P 4 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L08 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 4 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L08?\u003c\/h3\u003e\u003cp\u003eWith a 4 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L08 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2L08, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590170909,"sku":"GV2L08","price":4041.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3_f42bb2a9-b281-408d-b8b6-9fb9ee94caac.jpg?v=1791536568"},{"product_id":"schneider-electric-gv2l10-tesys-gv2-motor-circuit-breaker-3p-6-3a-magnetic","title":"Schneider Electric GV2L10 TeSys GV2 Motor Circuit Breaker 3P 6.3 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L10 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 6.3 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L10?\u003c\/h3\u003e\u003cp\u003eWith a 6.3 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L10 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2L10 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590236445,"sku":"GV2L10","price":4041.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3_f92d1db4-cd72-4a02-8ced-a942f9ce3923.jpg?v=1791536572"},{"product_id":"schneider-electric-gv2l14-tesys-gv2-motor-circuit-breaker-3p-10a-magnetic","title":"Schneider Electric GV2L14 TeSys GV2 Motor Circuit Breaker 3P 10 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L14 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 10 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L14?\u003c\/h3\u003e\u003cp\u003eWith a 10 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L14 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2L14 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590269213,"sku":"GV2L14","price":4880.49,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3_2d7d5f77-2059-48c0-a150-49f97c1fe1a4.jpg?v=1791536583"},{"product_id":"schneider-electric-gv2l16-tesys-gv2-motor-circuit-breaker-3p-14a-magnetic","title":"Schneider Electric GV2L16 TeSys GV2 Motor Circuit Breaker 3P 14 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L16 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 14 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L16?\u003c\/h3\u003e\u003cp\u003eWith a 14 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L16 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2L16 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590334749,"sku":"GV2L16","price":4880.49,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3_d45f84c6-58e9-4a5c-b411-35101247436b.jpg?v=1791536584"},{"product_id":"schneider-electric-gv2l20-tesys-gv2-motor-circuit-breaker-3p-18a-magnetic","title":"Schneider Electric GV2L20 TeSys GV2 Motor Circuit Breaker 3P 18 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L20 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 18 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L20?\u003c\/h3\u003e\u003cp\u003eWith a 18 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L20 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2L20 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590400285,"sku":"GV2L20","price":4880.49,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3_57a7e377-4757-4967-9b83-ff7c874c4dce.jpg?v=1791536595"},{"product_id":"schneider-electric-gv2l22-tesys-gv2-motor-circuit-breaker-3p-25a-magnetic","title":"Schneider Electric GV2L22 TeSys GV2 Motor Circuit Breaker 3P 25 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L22 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 25 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L22?\u003c\/h3\u003e\u003cp\u003eWith a 25 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L22 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2L22 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590433053,"sku":"GV2L22","price":6173.55,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3_d06d5351-eccf-4ade-988d-0975200dcb0c.jpg?v=1791536600"},{"product_id":"schneider-electric-gv2l32-tesys-gv2-motor-circuit-breaker-3p-32a-magnetic","title":"Schneider Electric GV2L32 TeSys GV2 Motor Circuit Breaker 3P 32 A Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2L32 is a TeSys GV2 magnetic-only motor circuit breaker with a setting range of 32 A. It provides magnetic short-circuit protection and isolation and is typically combined with a TeSys contactor and thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMagnetic trip for fast short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIdeal for motor-starter combinations with separate overload relays\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2L32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003emagnetic-only (short-circuit only – use with a thermal overload relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2L32?\u003c\/h3\u003e\u003cp\u003eWith a 32 A setting range it suits three-phase motors whose full-load current lies within that range.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2L32 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2L32 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590498589,"sku":"GV2L32","price":7234.42,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv2l08_image-1_1500x1500_9uqugzysypklnpv3_8b0338a7-918b-4d3a-898f-7cef130051dd.jpg?v=1791536598"},{"product_id":"schneider-electric-gv2me02-tesys-gv2-motor-circuit-breaker-3p-0-16-0-25a-thermal-magnetic","title":"Schneider Electric GV2ME02 TeSys GV2 Motor Circuit Breaker 3P 0.16–0.25 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME02 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.16–0.25 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.16–0.25 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.16–0.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.06 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME02?\u003c\/h3\u003e\u003cp\u003eWith a 0.16–0.25 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.06 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME02 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2ME02 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590531357,"sku":"GV2ME02","price":2837.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_a83e9abf-4d78-4e8c-a74d-d37ad725c4b7.png?v=1779987301"},{"product_id":"schneider-electric-gv2me04-tesys-gv2-motor-circuit-breaker-3p-0-4-0-63a-thermal-magnetic","title":"Schneider Electric GV2ME04 TeSys GV2 Motor Circuit Breaker 3P 0.4–0.63 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME04 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.4–0.63 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.4–0.63 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.4–0.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.18 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME04?\u003c\/h3\u003e\u003cp\u003eWith a 0.4–0.63 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.18 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME04 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2ME04, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590596893,"sku":"GV2ME04","price":2837.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_62b3d678-9bb4-4f89-bf6a-5acd2f826f82.png?v=1779987305"},{"product_id":"schneider-electric-gv2me05-tesys-gv2-motor-circuit-breaker-3p-0-63-1a-thermal-magnetic","title":"Schneider Electric GV2ME05 TeSys GV2 Motor Circuit Breaker 3P 0.63–1 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME05 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.63–1 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.63–1 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.63–1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.25 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME05?\u003c\/h3\u003e\u003cp\u003eWith a 0.63–1 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.25 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME05 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2ME05 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590629661,"sku":"GV2ME05","price":2962.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_a2494db5-d340-4fdb-a8bb-d1e9173e31db.png?v=1779987309"},{"product_id":"schneider-electric-gv2me06-tesys-gv2-motor-circuit-breaker-3p-1-1-6a-thermal-magnetic","title":"Schneider Electric GV2ME06 TeSys GV2 Motor Circuit Breaker 3P 1–1.6 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME06 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 1–1.6 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 1–1.6 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1–1.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME06?\u003c\/h3\u003e\u003cp\u003eWith a 1–1.6 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.55 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME06 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2ME06 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590695197,"sku":"GV2ME06","price":2962.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_f01cc772-bd84-44e9-8fc8-3f5bcab9b100.png?v=1779987314"},{"product_id":"schneider-electric-gv2me07-tesys-gv2-motor-circuit-breaker-3p-1-6-2-5a-thermal-magnetic","title":"Schneider Electric GV2ME07 TeSys GV2 Motor Circuit Breaker 3P 1.6–2.5 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME07 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 1.6–2.5 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 1.6–2.5 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1.6–2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME07?\u003c\/h3\u003e\u003cp\u003eWith a 1.6–2.5 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.75 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME07 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2ME07 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590727965,"sku":"GV2ME07","price":2962.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_805f84e9-ff3d-46a4-866d-297ede3dc58f.png?v=1779987320"},{"product_id":"schneider-electric-gv2me08-tesys-gv2-motor-circuit-breaker-3p-2-5-4a-thermal-magnetic","title":"Schneider Electric GV2ME08 TeSys GV2 Motor Circuit Breaker 3P 2.5–4 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME08 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 2.5–4 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 2.5–4 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2.5–4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 1.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME08?\u003c\/h3\u003e\u003cp\u003eWith a 2.5–4 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 1.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME08 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2ME08 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263590793501,"sku":"GV2ME08","price":2962.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_572b1e4b-7268-4e0b-8cde-2c3d51e13d40.png?v=1779987324"},{"product_id":"schneider-electric-gv2me10-tesys-gv2-motor-circuit-breaker-3p-4-6-3a-thermal-magnetic","title":"Schneider Electric GV2ME10 TeSys GV2 Motor Circuit Breaker 3P 4–6.3 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME10 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 4–6.3 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 4–6.3 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4–6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME10?\u003c\/h3\u003e\u003cp\u003eWith a 4–6.3 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 2.2 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME10 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2ME10 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591022877,"sku":"GV2ME10","price":2962.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_03f2e979-4892-4318-8c50-9b62c55105e4.png?v=1779987329"},{"product_id":"schneider-electric-gv2me14-tesys-gv2-motor-circuit-breaker-3p-6-10a-thermal-magnetic","title":"Schneider Electric GV2ME14 TeSys GV2 Motor Circuit Breaker 3P 6–10 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME14 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 6–10 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 6–10 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6–10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME14?\u003c\/h3\u003e\u003cp\u003eWith a 6–10 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 4 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME14 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2ME14 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591088413,"sku":"GV2ME14","price":3092.85,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_233282ec-b580-4503-9777-7220f05a73d3.png?v=1779987407"},{"product_id":"schneider-electric-gv2me16-tesys-gv2-motor-circuit-breaker-3p-9-14a-thermal-magnetic","title":"Schneider Electric GV2ME16 TeSys GV2 Motor Circuit Breaker 3P 9–14 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME16 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 9–14 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 9–14 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e9–14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME16?\u003c\/h3\u003e\u003cp\u003eWith a 9–14 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 5.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME16 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2ME16 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591121181,"sku":"GV2ME16","price":3092.85,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_c5cb0f27-1185-407c-b58d-4d0130aaddc6.png?v=1779987339"},{"product_id":"schneider-electric-gv2me20-tesys-gv2-motor-circuit-breaker-3p-17-23a-thermal-magnetic","title":"Schneider Electric GV2ME20 TeSys GV2 Motor Circuit Breaker 3P 13–18 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME20 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 13–18 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 13–18 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e13–18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME20?\u003c\/h3\u003e\u003cp\u003eWith a 13–18 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 7.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME20 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2ME20 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591186717,"sku":"GV2ME20","price":3092.85,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_fe9ac72d-2c24-4693-b0ab-a2cba862517c.png?v=1779987343"},{"product_id":"schneider-electric-gv2me21-tesys-gv2-motor-circuit-breaker-3p-17-23a-thermal-magnetic","title":"Schneider Electric GV2ME21 TeSys GV2 Motor Circuit Breaker 3P 17–23 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME21 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 17–23 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 17–23 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e17–23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME21?\u003c\/h3\u003e\u003cp\u003eWith a 17–23 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 11 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME21 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2ME21, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591219485,"sku":"GV2ME21","price":3230.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_4299fd49-4a3e-4a4e-8ed1-5ce594690c0f.png?v=1779987347"},{"product_id":"schneider-electric-gv2me22-tesys-gv2-motor-circuit-breaker-3p-20-25a-thermal-magnetic","title":"Schneider Electric GV2ME22 TeSys GV2 Motor Circuit Breaker 3P 20–25 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME22 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 20–25 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 20–25 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME22?\u003c\/h3\u003e\u003cp\u003eWith a 20–25 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 11 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME22 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2ME22 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591285021,"sku":"GV2ME22","price":3565.58,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_c66ec206-a505-458c-869a-88d223922967.png?v=1779987353"},{"product_id":"schneider-electric-gv2me32-tesys-gv2-motor-circuit-breaker-3p-24-32a-thermal-magnetic","title":"Schneider Electric GV2ME32 TeSys GV2 Motor Circuit Breaker 3P 24–32 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2ME32 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 24–32 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 24–32 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2ME32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e24–32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePush-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2ME32?\u003c\/h3\u003e\u003cp\u003eWith a 24–32 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 15 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2ME32 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2ME32 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591317789,"sku":"GV2ME32","price":5884.85,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_91f6e8c7-f22c-4da1-ba09-706b3adf8a8a.png?v=1779987357"},{"product_id":"gv2p01-motor-circuit-breaker-tesys-gv2-3p-0-1-0-16-a-thermal-magnetic-screw-clamp-termi","title":"Schneider Electric GV2P01 TeSys GV2 Motor Circuit Breaker 3P 0.1–0.16 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P01 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.1–0.16 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.1–0.16 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.1–0.16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.03 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P01?\u003c\/h3\u003e\u003cp\u003eWith a 0.1–0.16 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.03 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P01 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2P01, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591350557,"sku":null,"price":3646.5,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/R3950324-01_4671fbee-0148-422c-9d5d-15c8884f999e.webp?v=1791535970"},{"product_id":"gv2p02-motor-circuit-breaker-tesys-gv2-3p-0-16-0-25-a-thermal-magnetic-screw-clamp-term","title":"Schneider Electric GV2P02 TeSys GV2 Motor Circuit Breaker 3P 0.16–0.25 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P02 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.16–0.25 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.16–0.25 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.16–0.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.06 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P02?\u003c\/h3\u003e\u003cp\u003eWith a 0.16–0.25 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.06 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P02 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2P02, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591416093,"sku":null,"price":3969.77,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/R3950324-01_614c9313-463a-4e0d-828e-948517ccaafb.webp?v=1791535958"},{"product_id":"gv2p03-motor-circuit-breaker-tesys-gv2-3p-0-25-0-4-a-thermal-magnetic-screw-clamp-termi","title":"Schneider Electric GV2P03 TeSys GV2 Motor Circuit Breaker 3P 0.25–0.4 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P03 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.25–0.4 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.25–0.4 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.25–0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.09 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P03?\u003c\/h3\u003e\u003cp\u003eWith a 0.25–0.4 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.09 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P03 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P03 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591448861,"sku":null,"price":3646.5,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/R3950324-01_4abe6323-6ecf-4b64-a6e2-153cc3524162.webp?v=1791535950"},{"product_id":"gv2p04-motor-circuit-breaker-tesys-gv2-3p-0-4-0-63-a-thermal-magnetic-screw-clamp-termi","title":"Schneider Electric GV2P04 TeSys GV2 Motor Circuit Breaker 3P 0.4–0.63 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P04 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.4–0.63 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.4–0.63 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.4–0.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.18 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P04?\u003c\/h3\u003e\u003cp\u003eWith a 0.4–0.63 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.18 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P04 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P04 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591481629,"sku":null,"price":3646.5,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/R3950324-01.webp?v=1791535923"},{"product_id":"schneider-electric-gv2p05-tesys-gv2-motor-circuit-breaker-3p-0-63-1a-thermal-magnetic","title":"Schneider Electric GV2P05 TeSys GV2 Motor Circuit Breaker 3P 0.63–1 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P05 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 0.63–1 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 0.63–1 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.63–1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.25 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P05?\u003c\/h3\u003e\u003cp\u003eWith a 0.63–1 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.25 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P05 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P05 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591514397,"sku":"GV2P05","price":3831.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_10c3dbe5-7a73-4f38-a65a-8427f83bee22.png?v=1779987362"},{"product_id":"schneider-electric-gv2p06-tesys-gv2-motor-circuit-breaker-3p-1-1-6a-thermal-magnetic","title":"Schneider Electric GV2P06 TeSys GV2 Motor Circuit Breaker 3P 1–1.6 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P06 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 1–1.6 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 1–1.6 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1–1.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P06?\u003c\/h3\u003e\u003cp\u003eWith a 1–1.6 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.55 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P06 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P06 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591547165,"sku":"GV2P06","price":3831.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_ed636b81-0eea-433a-b2d7-d80d8b788d12.png?v=1779987367"},{"product_id":"schneider-electric-gv2p07-tesys-gv2-motor-circuit-breaker-3p-1-6-2-5a-thermal-magnetic","title":"Schneider Electric GV2P07 TeSys GV2 Motor Circuit Breaker 3P 1.6–2.5 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P07 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 1.6–2.5 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 1.6–2.5 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1.6–2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P07?\u003c\/h3\u003e\u003cp\u003eWith a 1.6–2.5 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 0.75 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P07 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2P07, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591612701,"sku":"GV2P07","price":3831.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_bb04d6e8-270f-44b1-a882-4e3674bf6057.png?v=1779987372"},{"product_id":"schneider-electric-gv2p08-tesys-gv2-motor-circuit-breaker-3p-2-5-4a-thermal-magnetic","title":"Schneider Electric GV2P08 TeSys GV2 Motor Circuit Breaker 3P 2.5–4 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P08 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 2.5–4 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 2.5–4 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2.5–4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 1.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P08?\u003c\/h3\u003e\u003cp\u003eWith a 2.5–4 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 1.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P08 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P08 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591678237,"sku":"GV2P08","price":4171.44,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_136beb6a-1974-4e47-b100-aa4988890c1e.png?v=1779987378"},{"product_id":"schneider-electric-gv2p10-tesys-gv2-motor-circuit-breaker-3p-4-6-3a-thermal-magnetic","title":"Schneider Electric GV2P10 TeSys GV2 Motor Circuit Breaker 3P 4–6.3 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P10 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 4–6.3 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 4–6.3 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4–6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P10?\u003c\/h3\u003e\u003cp\u003eWith a 4–6.3 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 2.2 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P10 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV2P10 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591743773,"sku":"GV2P10","price":4171.44,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_24177f2f-eaca-48f6-a017-c5788b4a9ca5.png?v=1779987384"},{"product_id":"schneider-electric-gv2p14-tesys-gv2-motor-circuit-breaker-3p-6-10a-thermal-magnetic","title":"Schneider Electric GV2P14 TeSys GV2 Motor Circuit Breaker 3P 6–10 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P14 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 6–10 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 6–10 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6–10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P14?\u003c\/h3\u003e\u003cp\u003eWith a 6–10 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 4 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P14 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P14 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591809309,"sku":"GV2P14","price":4248.89,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_5eb15e9a-304a-4e93-9954-fb7d3927567c.png?v=1779987403"},{"product_id":"schneider-electric-gv2p16-tesys-gv2-motor-circuit-breaker-3p-9-14a-thermal-magnetic","title":"Schneider Electric GV2P16 TeSys GV2 Motor Circuit Breaker 3P 9–14 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P16 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 9–14 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 9–14 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e9–14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P16?\u003c\/h3\u003e\u003cp\u003eWith a 9–14 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 5.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P16 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2P16, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591874845,"sku":"GV2P16","price":5009.56,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_44243eda-11d8-4356-8947-aaa099dbd297.png?v=1779987408"},{"product_id":"schneider-electric-gv2p20-tesys-gv2-motor-circuit-breaker-3p-13-18a-thermal-magnetic","title":"Schneider Electric GV2P20 TeSys GV2 Motor Circuit Breaker 3P 13–18 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P20 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 13–18 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 13–18 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e13–18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P20?\u003c\/h3\u003e\u003cp\u003eWith a 13–18 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 7.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P20 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P20 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591907613,"sku":"GV2P20","price":5009.56,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_63644910-9ba8-4462-91c3-821b2af06832.png?v=1779987412"},{"product_id":"schneider-electric-gv2p21-tesys-gv2-motor-circuit-breaker-3p-17-23a-thermal-magnetic","title":"Schneider Electric GV2P21 TeSys GV2 Motor Circuit Breaker 3P 17–23 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P21 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 17–23 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 17–23 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e17–23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P21?\u003c\/h3\u003e\u003cp\u003eWith a 17–23 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 11 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P21 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P21 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591940381,"sku":"GV2P21","price":5631.55,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_bb58da71-66a9-433d-9365-e6b0df95984e.png?v=1779987418"},{"product_id":"schneider-electric-gv2p22-tesys-gv2-motor-circuit-breaker-3p-20-25a-thermal-magnetic","title":"Schneider Electric GV2P22 TeSys GV2 Motor Circuit Breaker 3P 20–25 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P22 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 20–25 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 20–25 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P22?\u003c\/h3\u003e\u003cp\u003eWith a 20–25 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 11 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P22 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV2P22, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263591973149,"sku":"GV2P22","price":4939.96,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_8a1e9ae6-056f-48c9-b08e-7454dbfa8e02.png?v=1779987425"},{"product_id":"schneider-electric-gv2p32-tesys-gv2-motor-circuit-breaker-3p-24-32a-thermal-magnetic","title":"Schneider Electric GV2P32 TeSys GV2 Motor Circuit Breaker 3P 24–32 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV2P32 is a TeSys GV2 thermal-magnetic motor circuit breaker with a setting range of 24–32 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 24–32 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV2P32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e24–32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV2P32?\u003c\/h3\u003e\u003cp\u003eWith a 24–32 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 15 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV2P32 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV2P32 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592005917,"sku":"GV2P32","price":7113.6,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_636e0d41-52a6-440b-ac2a-603b7d7ef8d0.png?v=1779987443"},{"product_id":"schneider-electric-gv3p13-tesys-gv3-motor-circuit-breaker-3p-9-13a-thermal-magnetic","title":"Schneider Electric GV3P13 TeSys GV3 Motor Circuit Breaker 3P 9–13 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P13 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 9–13 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 9–13 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e9–13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P13?\u003c\/h3\u003e\u003cp\u003eWith a 9–13 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 5.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P13 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV3P13 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592038685,"sku":"GV3P13","price":8796.17,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_7a2e4a75-b7d9-4cf5-b12b-a570fcab4622.png?v=1779987448"},{"product_id":"schneider-electric-gv3p18-tesys-gv3-motor-circuit-breaker-3p-12-18a-thermal-magnetic","title":"Schneider Electric GV3P18 TeSys GV3 Motor Circuit Breaker 3P 12–18 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P18 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 12–18 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 12–18 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e12–18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P18?\u003c\/h3\u003e\u003cp\u003eWith a 12–18 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 7.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P18 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV3P18 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592071453,"sku":"GV3P18","price":9351.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_1332354c-0087-4183-9796-8b4e58e233b5.png?v=1779987452"},{"product_id":"schneider-electric-gv3p25-tesys-gv3-motor-circuit-breaker-3p-17-25a-thermal-magnetic","title":"Schneider Electric GV3P25 TeSys GV3 Motor Circuit Breaker 3P 17–25 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P25 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 17–25 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 17–25 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e17–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P25?\u003c\/h3\u003e\u003cp\u003eWith a 17–25 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 11 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P25 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric GV3P25 motor circuit breaker (MPCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592104221,"sku":"GV3P25","price":10345.02,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_714d3c0a-cf71-4823-8685-42aaf3427128.png?v=1779987457"},{"product_id":"schneider-electric-gv3p32-tesys-gv3-motor-circuit-breaker-3p-23-32a-thermal-magnetic","title":"Schneider Electric GV3P32 TeSys GV3 Motor Circuit Breaker 3P 23–32 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P32 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 23–32 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 23–32 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e23–32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P32?\u003c\/h3\u003e\u003cp\u003eWith a 23–32 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 15 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P32 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV3P32 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592136989,"sku":"GV3P32","price":10532.18,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_6aaf177b-5e4c-49df-a8c9-1c28566370c3.png?v=1779987462"},{"product_id":"schneider-electric-gv3p40-tesys-gv3-motor-circuit-breaker-3p-30-40a-thermal-magnetic","title":"Schneider Electric GV3P40 TeSys GV3 Motor Circuit Breaker 3P 30–40 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P40 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 30–40 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 30–40 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30–40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P40?\u003c\/h3\u003e\u003cp\u003eWith a 30–40 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 18.5 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P40 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV3P40 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592169757,"sku":"GV3P40","price":11145.27,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_401e48b7-9d0f-4504-adec-e0223372f8d0.png?v=1779987467"},{"product_id":"schneider-electric-gv3p50-tesys-gv3-motor-circuit-breaker-3p-37-50a-thermal-magnetic","title":"Schneider Electric GV3P50 TeSys GV3 Motor Circuit Breaker 3P 37–50 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P50 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 37–50 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 37–50 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e37–50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P50?\u003c\/h3\u003e\u003cp\u003eWith a 37–50 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 22 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P50 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV3P50, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592202525,"sku":"GV3P50","price":11254.98,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_00289e99-a42f-458e-bff1-beef3768f300.png?v=1779987472"},{"product_id":"schneider-electric-gv3p65-tesys-gv3-motor-circuit-breaker-3p-48-65a-thermal-magnetic","title":"Schneider Electric GV3P65 TeSys GV3 Motor Circuit Breaker 3P 48–65 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P65 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 48–65 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 48–65 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e48–65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P65?\u003c\/h3\u003e\u003cp\u003eWith a 48–65 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 30 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P65 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric motor circuit breaker (MPCB)s such as the GV3P65, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592235293,"sku":"GV3P65","price":11706.73,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_c464df29-261e-4e32-8efc-648d6280ecd5.png?v=1779987508"},{"product_id":"schneider-electric-gv3p73-tesys-gv3-motor-circuit-breaker-3p-62-73a-thermal-magnetic","title":"Schneider Electric GV3P73 TeSys GV3 Motor Circuit Breaker 3P 62–73 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P73 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 62–73 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 62–73 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e62–73 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P73?\u003c\/h3\u003e\u003cp\u003eWith a 62–73 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 37 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P73 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV3P73 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592464669,"sku":"GV3P73","price":13197.5,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv3p80_1_8f0d3487-3f17-481d-a8dd-5083a3a4d1da.webp?v=1791535704"},{"product_id":"schneider-electric-gv3p80-tesys-gv3-motor-circuit-breaker-3p-70-80a-thermal-magnetic","title":"Schneider Electric GV3P80 TeSys GV3 Motor Circuit Breaker 3P 70–80 A Thermal-Magnetic | MPCB","description":"\u003cp\u003eThe Schneider Electric GV3P80 is a TeSys GV3 thermal-magnetic motor circuit breaker with a setting range of 70–80 A. It protects three-phase motors against overload, short circuit and phase failure, and can also be used to start and stop the motor manually – replacing a breaker plus overload relay in one compact unit.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable thermal setting 70–80 A to match the motor nameplate current\u003c\/li\u003e\n\u003cli\u003ePhase-failure sensitivity for three-phase motors\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF\/TRIP indication and lockable handle for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDirect mounting with TeSys contactors to build compact starters\u003c\/li\u003e\n\u003cli\u003eAccepts auxiliary contacts, fault signalling contacts and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eGV3P80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMotor circuit breaker \/ manual motor starter (MPCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ethermal-magnetic (overload + short circuit + phase loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSetting \/ rated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70–80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTypical motor power (400 V AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e≈ 37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pumps, booster sets and fire pumps\u003c\/li\u003e\n\u003cli\u003eFans, blowers, compressors and conveyors\u003c\/li\u003e\n\u003cli\u003eHVAC, chiller and cooling-tower motors\u003c\/li\u003e\n\u003cli\u003eMachine control panels and MCCs\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the range so that the motor full-load current (from the nameplate) falls inside the setting range, then set the dial exactly to the nameplate current. For example, a 7.5 kW 400 V motor draws about 15 A, so a 13–18 A range is appropriate.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat motor size suits the GV3P80?\u003c\/h3\u003e\u003cp\u003eWith a 70–80 A setting range it suits three-phase motors whose full-load current lies within that range – roughly up to 37 kW at 400 V.\u003c\/p\u003e\u003ch3\u003eDo I need an overload relay with this breaker?\u003c\/h3\u003e\u003cp\u003eNo for thermal-magnetic GV2ME\/GV2P\/GV3P\/GZ1E types, which include overload protection. Yes for magnetic-only GV2L types, which must be combined with a thermal overload relay.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider GV3P80 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric GV3P80 from Spark Egypt and receive an original motor circuit breaker (MPCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263592497437,"sku":"GV3P80","price":14449.48,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/gv3p80_1.webp?v=1791535679"}],"url":"https:\/\/www.spark-eshop.com\/collections\/category-motor-circuit-breakers.oembed?page=8","provider":"Spark","version":"1.0","type":"link"}