{"title":"Application - Power Monitoring Applications","description":null,"products":[{"product_id":"schneider-51207-varlogic-power-factor-controller-6-steps","title":"Schneider Electric 51207 Varlogic Power Factor Controller 6 Steps","description":"\u003cp\u003eThe Schneider Electric 51207 is a Varlogic automatic power factor controller with 6 steps. It measures the network power factor and switches capacitor-bank steps in and out through capacitor contactors to keep the target cos φ.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic step switching with configurable target power factor\u003c\/li\u003e\n\u003cli\u003eDisplay of cos φ and alarms\u003c\/li\u003e\n\u003cli\u003ePanel-door mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e51207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAutomatic power factor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of steps\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAPFC panels\u003c\/li\u003e\n\u003cli\u003eFactories and commercial buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 51207 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 51207 from Spark Egypt and receive an original power factor controller with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560581405,"sku":"51207","price":9337.45,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/ODA51207_web-1_jpg.webp?v=1791326734"},{"product_id":"schneider-51213-varlogic-power-factor-controller-12-steps","title":"Schneider Electric 51213 Varlogic Power Factor Controller 12 Steps","description":"\u003cp\u003eThe Schneider Electric 51213 is a Varlogic automatic power factor controller with 12 steps. It measures the network power factor and switches capacitor-bank steps in and out through capacitor contactors to keep the target cos φ.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic step switching with configurable target power factor\u003c\/li\u003e\n\u003cli\u003eDisplay of cos φ and alarms\u003c\/li\u003e\n\u003cli\u003ePanel-door mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e51213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAutomatic power factor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of steps\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAPFC panels\u003c\/li\u003e\n\u003cli\u003eFactories and commercial buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 51213 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 51213 from Spark Egypt and receive an original power factor controller with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560646941,"sku":"51213","price":14834.25,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/l-3_jpg.webp?v=1791326836"},{"product_id":"schneider-59642-sepam-ace949-2-rs485-interface-module","title":"Schneider Electric 59642 ACE949-2 RS485 Interface Module for Sepam Series 20\/40\/60\/80 – Modbus RTU Communication","description":"\u003cp\u003eThe Schneider Electric 59642 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: ACE949-2 RS485 Interface Module for Sepam Series 20\/40\/60\/80 – Modbus RTU Communication. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59642\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eACE949-2 RS485 Interface Module for Sepam Series 20\/40\/60\/80 – Modbus RTU Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59642 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 59642 from Spark Egypt and receive an original medium-voltage protection relay component with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560810781,"sku":"59642","price":17712.75,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_ffad2f4e-6994-49b9-a8a1-f68ef26b02fd.jpg?v=1785582758"},{"product_id":"schneider-59704-sepam-base-unit-sep383-for-sepam-series-80-24","title":"Schneider Electric 59704 base unit SEP383 for Sepam series 80 - 24…250 V - with advanced UMI","description":"\u003cp\u003eThe Schneider Electric 59704 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: base unit SEP383 for Sepam series 80 - 24…250 V - with advanced UMI. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ebase unit SEP383 for Sepam series 80 - 24…250 V - with advanced UMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59704 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric medium-voltage protection relay components such as the 59704, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560843549,"sku":"59704","price":17712.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_08d4dd9b-dc97-4a9e-ae9b-df92506712ed.jpg?v=1785582697"},{"product_id":"schneider-electric-59707-memory-cartridge-mms020-sepam-series-80-default-title","title":"Schneider Electric 59707 memory cartridge MMS020 Sepam series 80","description":"\u003cp\u003eThe Schneider Electric 59707 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: memory cartridge MMS020 Sepam series 80. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ememory cartridge MMS020 Sepam series 80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59707 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 59707 from Spark Egypt and receive an original medium-voltage protection relay component with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560876317,"sku":"59707","price":17712.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_1b25851d-8ecc-421d-b38f-a0ca5164b46e.jpg?v=1785582575"},{"product_id":"schneider-59715-sepam-i-o-module-mes120-sepam-series-60-80-14","title":"Schneider Electric 59715 I\/O module MES120 - Sepam series 60, 80 - 14 inputs+ 6 outputs 24...250V DC","description":"\u003cp\u003eThe Schneider Electric 59715 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: I\/O module MES120 - Sepam series 60, 80 - 14 inputs+ 6 outputs 24...250V DC. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eI\/O module MES120 - Sepam series 60, 80 - 14 inputs+ 6 outputs 24...250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59715 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric medium-voltage protection relay components such as the 59715, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560941853,"sku":"59715","price":17712.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/download_858e9136-e92a-4ad7-899c-b65711a23d3c.jpg?v=1785582518"},{"product_id":"schneider-blrch050a060b40-varplus-can-hduty-capacitor-5kvar-400v","title":"Schneider Electric BLRCH050A060B40 VarPlus Can Heavy Duty PFC Capacitor 5 kvar 400V 50Hz (6 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCH050A060B40 is a VarPlus Can heavy duty three-phase capacitor rated 5 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eHeavy-duty design for higher temperatures and harmonics\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCH050A060B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e5 kvar at 50 Hz \/ 6 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHeavy Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCH050A060B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCH050A060B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576113437,"sku":"BLRCH050A060B40","price":3350.89,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_4bfdbd40-8c08-4308-abed-deb3f98bfe03.png?v=1780587967"},{"product_id":"schneider-blrch104a125b40-varplus-can-hduty-capacitor-10-4kvar-400v","title":"Schneider Electric BLRCH104A125B40 VarPlus Can Heavy Duty PFC Capacitor 10.4 kvar 400V 50Hz (12.5 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCH104A125B40 is a VarPlus Can heavy duty three-phase capacitor rated 10.4 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eHeavy-duty design for higher temperatures and harmonics\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCH104A125B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10.4 kvar at 50 Hz \/ 12.5 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHeavy Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCH104A125B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCH104A125B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576146205,"sku":"BLRCH104A125B40","price":3914.4,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_1195aa36-2ff9-4bcb-ab06-767b1a294f3f.png?v=1780587977"},{"product_id":"schneider-blrch125a150b40-varplus-can-hduty-capacitor-12-5kvar-400v","title":"Schneider Electric BLRCH125A150B40 VarPlus Can Heavy Duty PFC Capacitor 12.5 kvar 400V 50Hz (15 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCH125A150B40 is a VarPlus Can heavy duty three-phase capacitor rated 12.5 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eHeavy-duty design for higher temperatures and harmonics\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCH125A150B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e12.5 kvar at 50 Hz \/ 15 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHeavy Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCH125A150B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCH125A150B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576178973,"sku":"BLRCH125A150B40","price":4177.44,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_d252a97f-b4b0-4e07-86c8-5df24195aff8.png?v=1780588053"},{"product_id":"schneider-blrch150a180b40-varplus-can-hduty-capacitor-15kvar-400v","title":"Schneider Electric BLRCH150A180B40 VarPlus Can Heavy Duty PFC Capacitor 15 kvar 400V 50Hz (18 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCH150A180B40 is a VarPlus Can heavy duty three-phase capacitor rated 15 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eHeavy-duty design for higher temperatures and harmonics\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCH150A180B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e15 kvar at 50 Hz \/ 18 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHeavy Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCH150A180B40 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric BLRCH150A180B40 from Spark Egypt and receive an original power factor correction capacitor with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576211741,"sku":"BLRCH150A180B40","price":4617.22,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_de83433d-dd0c-48c9-a104-1a895fb3f94a.png?v=1780588088"},{"product_id":"schneider-blrch200a240b40-varplus-can-hduty-capacitor-20kvar-400v","title":"Schneider Electric BLRCH200A240B40 VarPlus Can Heavy Duty PFC Capacitor 20 kvar 400V 50Hz (24 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCH200A240B40 is a VarPlus Can heavy duty three-phase capacitor rated 20 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eHeavy-duty design for higher temperatures and harmonics\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCH200A240B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20 kvar at 50 Hz \/ 24 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHeavy Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCH200A240B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCH200A240B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576244509,"sku":"BLRCH200A240B40","price":5642.34,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_fffb659f-cce9-4445-9d00-9ae6d173394c.png?v=1780588142"},{"product_id":"schneider-blrch250a300b40-varplus-can-hduty-capacitor-25kvar-400v","title":"Schneider Electric BLRCH250A300B40 VarPlus Can Heavy Duty PFC Capacitor 25 kvar 400V 50Hz (30 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCH250A300B40 is a VarPlus Can heavy duty three-phase capacitor rated 25 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eHeavy-duty design for higher temperatures and harmonics\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCH250A300B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kvar at 50 Hz \/ 30 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHeavy Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCH250A300B40 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric BLRCH250A300B40 from Spark Egypt and receive an original power factor correction capacitor with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576342813,"sku":"BLRCH250A300B40","price":6100.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_3f6d2960-6a08-4216-92af-7d84090962f9.png?v=1780588196"},{"product_id":"schneider-blrch300a360b40-varplus-can-hduty-capacitor-30kvar-400v","title":"Schneider Electric BLRCH300A360B40 VarPlus Can Heavy Duty PFC Capacitor 30 kvar 400V 50Hz (36 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCH300A360B40 is a VarPlus Can heavy duty three-phase capacitor rated 30 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eHeavy-duty design for higher temperatures and harmonics\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCH300A360B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 kvar at 50 Hz \/ 36 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eHeavy Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCH300A360B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric BLRCH300A360B40 power factor correction capacitor with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576375581,"sku":"BLRCH300A360B40","price":7815.27,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_351ed934-1da5-46d4-8d2a-7b4e23335287.png?v=1780588213"},{"product_id":"schneider-electric-blrcs050a060b40-power-factor-correction-capacitor","title":"Schneider Electric BLRCS050A060B40 VarPlus Can Standard Duty PFC Capacitor 5 kvar 400V 50Hz (6 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCS050A060B40 is a VarPlus Can standard duty three-phase capacitor rated 5 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eCost-effective design for standard networks\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCS050A060B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e5 kvar at 50 Hz \/ 6 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eStandard Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCS050A060B40 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric BLRCS050A060B40 from Spark Egypt and receive an original power factor correction capacitor with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576408349,"sku":"BLRCS050A060B40","price":2590.88,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_e6683e08-1a42-4662-953c-d03927bcea06.png?v=1780588233"},{"product_id":"schneider-electric-blrcs104a125b40-power-factor-correction-capacitor","title":"Schneider Electric BLRCS104A125B40 VarPlus Can Standard Duty PFC Capacitor 10.4 kvar 400V 50Hz (12.5 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCS104A125B40 is a VarPlus Can standard duty three-phase capacitor rated 10.4 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eCost-effective design for standard networks\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCS104A125B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10.4 kvar at 50 Hz \/ 12.5 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eStandard Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCS104A125B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCS104A125B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576441117,"sku":"BLRCS104A125B40","price":2971.41,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_1b54cafa-0742-4da6-a20a-3d0547249d02.png?v=1780588253"},{"product_id":"schneider-electric-blrcs125a150b40-power-factor-correction-capacitor","title":"Schneider Electric BLRCS125A150B40 VarPlus Can Standard Duty PFC Capacitor 12.5 kvar 400V 50Hz (15 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCS125A150B40 is a VarPlus Can standard duty three-phase capacitor rated 12.5 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eCost-effective design for standard networks\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCS125A150B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e12.5 kvar at 50 Hz \/ 15 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eStandard Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCS125A150B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCS125A150B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576506653,"sku":"BLRCS125A150B40","price":2338.46,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_3c134975-4234-4ffd-a7bd-f9fa2e56ed5c.png?v=1780588314"},{"product_id":"schneider-electric-blrcs150a180b40-power-factor-correction-capacitor","title":"Schneider Electric BLRCS150A180B40 VarPlus Can Standard Duty PFC Capacitor 15 kvar 400V 50Hz (18 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCS150A180B40 is a VarPlus Can standard duty three-phase capacitor rated 15 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eCost-effective design for standard networks\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCS150A180B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e15 kvar at 50 Hz \/ 18 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eStandard Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCS150A180B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCS150A180B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576539421,"sku":"BLRCS150A180B40","price":3542.19,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_fa536c82-2d85-422c-94eb-10418f87db2a.png?v=1780588367"},{"product_id":"schneider-electric-blrcs200a240b40-power-factor-correction-capacitor","title":"Schneider Electric BLRCS200A240B40 VarPlus Can Standard Duty PFC Capacitor 20 kvar 400V 50Hz (24 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCS200A240B40 is a VarPlus Can standard duty three-phase capacitor rated 20 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eCost-effective design for standard networks\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCS200A240B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20 kvar at 50 Hz \/ 24 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eStandard Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCS200A240B40 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric BLRCS200A240B40 from Spark Egypt and receive an original power factor correction capacitor with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576572189,"sku":"BLRCS200A240B40","price":3342.05,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_f80e420d-4807-4732-be1b-96b4d1de2432.png?v=1780588376"},{"product_id":"schneider-electric-blrcs250a300b40-power-factor-correction-capacitor","title":"Schneider Electric BLRCS250A300B40 VarPlus Can Standard Duty PFC Capacitor 25 kvar 400V 50Hz (30 kvar 60Hz)","description":"\u003cp\u003eThe Schneider Electric BLRCS250A300B40 is a VarPlus Can standard duty three-phase capacitor rated 25 kvar at 400 V 50 Hz. Installed in automatic power factor correction (APFC) panels, it compensates reactive power of motors and inductive loads, raises the power factor, reduces line current and helps avoid utility low-power-factor penalties.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-healing metallised polypropylene film\u003c\/li\u003e\n\u003cli\u003eBuilt-in discharge resistors and overpressure disconnector\u003c\/li\u003e\n\u003cli\u003eCost-effective design for standard networks\u003c\/li\u003e\n\u003cli\u003eCompact can format for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eBLRCS250A300B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarPlus Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eThree-phase power factor correction capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReactive power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kvar at 50 Hz \/ 30 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDuty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eStandard Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eCylindrical aluminium can, self-healing metallised film, with discharge resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic PFC panels in factories\u003c\/li\u003e\n\u003cli\u003eCommercial buildings and malls\u003c\/li\u003e\n\u003cli\u003eFixed compensation of large motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eHeavy duty or standard duty?\u003c\/h3\u003e\u003cp\u003eChoose heavy duty (BLRCH) where harmonics, high ambient temperature or frequent switching are expected; standard duty (BLRCS) suits clean networks with mostly linear loads.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider BLRCS250A300B40 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric power factor correction capacitors such as the BLRCS250A300B40, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576604957,"sku":"BLRCS250A300B40","price":5013.33,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_76444330-41b1-492c-ade9-9327a70da53c.png?v=1780588382"},{"product_id":"schneider-electric-c10b3tm100-compact-nsx-mccb-nsx100b-3p-100a-25ka-tmd-trip-unit","title":"Schneider Electric C10B3TM100 ComPacT NSX MCCB NSX100B 3P 100A 25kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10B3TM100 is a ComPacT NSX NSX100B molded case circuit breaker rated 100A, 3-pole, with 25 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 25 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10B3TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100B – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10B3TM100?\u003c\/h3\u003e\u003cp\u003eThe C10B3TM100 (NSX100B) has a breaking capacity of 25 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10B3TM100 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C10B3TM100, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576637725,"sku":"C10B3TM100","price":9845.45,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_ebf1d19d-772b-49fa-af88-50de67c18337.webp?v=1779980944"},{"product_id":"schneider-electric-c10f3tm100-compact-nsx-mccb-nsx100f-3p-100a-36ka-tmd-trip-unit","title":"Schneider Electric C10F3TM100 ComPacT NSX MCCB NSX100F 3P 100A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM100 is a ComPacT NSX NSX100F molded case circuit breaker rated 100A, 3-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10F3TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100F – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10F3TM100?\u003c\/h3\u003e\u003cp\u003eThe C10F3TM100 (NSX100F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10F3TM100 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C10F3TM100 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576899869,"sku":"C10F3TM100","price":11575.38,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_fda68fbf-97d2-4d08-bb5f-90c0692ad475.webp?v=1779980787"},{"product_id":"schneider-electric-c10f6tm040-compact-nsx-mccb-nsx100f-4p-40a-36ka-tmd-trip-unit","title":"Schneider Electric C10F6TM040 ComPacT NSX MCCB NSX100F 4P 40A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F6TM040 is a ComPacT NSX NSX100F molded case circuit breaker rated 40A, 4-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10F6TM040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100F – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\/4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10F6TM040?\u003c\/h3\u003e\u003cp\u003eThe C10F6TM040 (NSX100F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10F6TM040 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C10F6TM040, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576932637,"sku":"C10F6TM040","price":14684.47,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C25W4TM250_ISO_369_493f5586-15f6-4eb5-af6f-4bf51e002ccf.jpg?v=1779978993"},{"product_id":"schneider-electric-c10f6tm063-compact-nsx-mccb-nsx100f-4p-63a-36ka-tmd-trip-unit","title":"Schneider Electric C10F6TM063 ComPacT NSX MCCB NSX100F 4P 63A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F6TM063 is a ComPacT NSX NSX100F molded case circuit breaker rated 63A, 4-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10F6TM063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100F – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\/4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10F6TM063?\u003c\/h3\u003e\u003cp\u003eThe C10F6TM063 (NSX100F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10F6TM063 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C10F6TM063 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576965405,"sku":"C10F6TM063","price":14684.47,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C25W4TM250_ISO_369_bb0c6a69-6bf8-4aca-b4bd-ce8e529f9eb0.jpg?v=1779978958"},{"product_id":"schneider-electric-c10h3ma100-compact-nsx-mccb-nsx100h-3p-100a-70ka-ma-trip-unit","title":"Schneider Electric C10H3MA100 ComPacT NSX MCCB NSX100H 3P 100A 70kA MA | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10H3MA100 is a ComPacT NSX NSX100H molded case circuit breaker rated 100A, 3-pole, with 70 kA breaking capacity and a MA magnetic-only (motor) trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMa magnetic-only (motor) protection\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10H3MA100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100H – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMA magnetic-only (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10H3MA100?\u003c\/h3\u003e\u003cp\u003eThe C10H3MA100 (NSX100H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10H3MA100 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C10H3MA100 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263576998173,"sku":"C10H3MA100","price":14856.84,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C25W3MA220_ISO_369.jpg?v=1779978629"},{"product_id":"schneider-electric-c10h3tm100-compact-nsx-mccb-nsx100h-3p-100a-70ka-tmd-trip-unit","title":"Schneider Electric C10H3TM100 ComPacT NSX MCCB NSX100H 3P 100A 70kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10H3TM100 is a ComPacT NSX NSX100H molded case circuit breaker rated 100A, 3-pole, with 70 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10H3TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100H – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10H3TM100?\u003c\/h3\u003e\u003cp\u003eThe C10H3TM100 (NSX100H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10H3TM100 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C10H3TM100, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577030941,"sku":"C10H3TM100","price":14485.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_8c0164f2-3213-4d9f-afbf-f4e89c981c8c.webp?v=1779978451"},{"product_id":"schneider-electric-c10h4tm100-compact-nsx-mccb-nsx100h-4p-100a-70ka-tmd-trip-unit","title":"Schneider Electric C10H4TM100 ComPacT NSX MCCB NSX100H 4P 100A 70kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10H4TM100 is a ComPacT NSX NSX100H molded case circuit breaker rated 100A, 4-pole, with 70 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10H4TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100H – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\/4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10H4TM100?\u003c\/h3\u003e\u003cp\u003eThe C10H4TM100 (NSX100H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10H4TM100 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C10H4TM100 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577096477,"sku":"C10H4TM100","price":21516.36,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C25W4TM250_ISO_369.jpg?v=1779978335"},{"product_id":"schneider-electric-c10n3tm100-compact-nsx-mccb-nsx100n-3p-100a-50ka-tmd-trip-unit","title":"Schneider Electric C10N3TM100 ComPacT NSX MCCB NSX100N 3P 100A 50kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10N3TM100 is a ComPacT NSX NSX100N molded case circuit breaker rated 100A, 3-pole, with 50 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC10N3TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX100N – 100 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C10N3TM100?\u003c\/h3\u003e\u003cp\u003eThe C10N3TM100 (NSX100N) has a breaking capacity of 50 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C10N3TM100 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C10N3TM100, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577129245,"sku":"C10N3TM100","price":13209.64,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_06cacd2f-18d9-42c8-a41b-5248c23d18b2.webp?v=1779978003"},{"product_id":"schneider-electric-c16b3tm100-compact-nsx-mccb-nsx160b-3p-100a-25ka-tmd-trip-unit","title":"Schneider Electric C16B3TM100 ComPacT NSX MCCB NSX160B 3P 100A 25kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16B3TM100 is a ComPacT NSX NSX160B molded case circuit breaker rated 100A, 3-pole, with 25 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 25 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16B3TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160B – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16B3TM100?\u003c\/h3\u003e\u003cp\u003eThe C16B3TM100 (NSX160B) has a breaking capacity of 25 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16B3TM100 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C16B3TM100 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577162013,"sku":"C16B3TM100","price":11822.51,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_fda68fbf-97d2-4d08-bb5f-90c0692ad475.webp?v=1779980787"},{"product_id":"schneider-electric-c16b3tm125-compact-nsx-mccb-nsx160b-3p-125a-25ka-tmd-trip-unit","title":"Schneider Electric C16B3TM125 ComPacT NSX MCCB NSX160B 3P 125A 25kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16B3TM125 is a ComPacT NSX NSX160B molded case circuit breaker rated 125A, 3-pole, with 25 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 25 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16B3TM125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160B – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16B3TM125?\u003c\/h3\u003e\u003cp\u003eThe C16B3TM125 (NSX160B) has a breaking capacity of 25 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16B3TM125 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C16B3TM125, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577194781,"sku":"C16B3TM125","price":12045.72,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_ebf1d19d-772b-49fa-af88-50de67c18337.webp?v=1779980944"},{"product_id":"schneider-electric-c16b3tm160-compact-nsx-mccb-nsx160b-3p-160a-25ka-tmd-trip-unit","title":"Schneider Electric C16B3TM160 ComPacT NSX MCCB NSX160B 3P 160A 25kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16B3TM160 is a ComPacT NSX NSX160B molded case circuit breaker rated 160A, 3-pole, with 25 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 25 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16B3TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160B – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16B3TM160?\u003c\/h3\u003e\u003cp\u003eThe C16B3TM160 (NSX160B) has a breaking capacity of 25 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16B3TM160 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C16B3TM160 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577227549,"sku":"C16B3TM160","price":14094.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_ebf1d19d-772b-49fa-af88-50de67c18337.webp?v=1779980944"},{"product_id":"schneider-electric-c16f3tm125-compact-nsx-mccb-nsx160f-3p-125a-36ka-tmd-trip-unit","title":"Schneider Electric C16F3TM125 ComPacT NSX MCCB NSX160F 3P 125A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16F3TM125 is a ComPacT NSX NSX160F molded case circuit breaker rated 125A, 3-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16F3TM125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160F – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16F3TM125?\u003c\/h3\u003e\u003cp\u003eThe C16F3TM125 (NSX160F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16F3TM125 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C16F3TM125 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577293085,"sku":"C16F3TM125","price":14150.34,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_ebf1d19d-772b-49fa-af88-50de67c18337.webp?v=1779980944"},{"product_id":"schneider-electric-c16f3tm160-compact-nsx-mccb-nsx160f-3p-160a-36ka-tmd-trip-unit","title":"Schneider Electric C16F3TM160 ComPacT NSX MCCB NSX160F 3P 160A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16F3TM160 is a ComPacT NSX NSX160F molded case circuit breaker rated 160A, 3-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16F3TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160F – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16F3TM160?\u003c\/h3\u003e\u003cp\u003eThe C16F3TM160 (NSX160F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16F3TM160 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C16F3TM160 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577358621,"sku":"C16F3TM160","price":16573.83,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_ebf1d19d-772b-49fa-af88-50de67c18337.webp?v=1779980944"},{"product_id":"schneider-electric-c16f4tm160-compact-nsx-mccb-nsx160f-4p-160a-36ka-tmd-trip-unit","title":"Schneider Electric C16F4TM160 ComPacT NSX MCCB NSX160F 4P 160A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16F4TM160 is a ComPacT NSX NSX160F molded case circuit breaker rated 160A, 4-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16F4TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160F – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\/4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16F4TM160?\u003c\/h3\u003e\u003cp\u003eThe C16F4TM160 (NSX160F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16F4TM160 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C16F4TM160 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577391389,"sku":"C16F4TM160","price":22163.39,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C16H4TM160-image_web.jpg?v=1779982144"},{"product_id":"schneider-electric-c16f6tm160-compact-nsx-mccb-nsx160f-4p-160a-36ka-tmd-trip-unit","title":"Schneider Electric C16F6TM160 ComPacT NSX MCCB NSX160F 4P 160A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16F6TM160 is a ComPacT NSX NSX160F molded case circuit breaker rated 160A, 4-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16F6TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160F – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\/4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16F6TM160?\u003c\/h3\u003e\u003cp\u003eThe C16F6TM160 (NSX160F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16F6TM160 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C16F6TM160 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577424157,"sku":"C16F6TM160","price":19304.76,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C16H4TM160-image_web.jpg?v=1779982144"},{"product_id":"schneider-electric-c16h3tm160-compact-nsx-mccb-nsx160h-3p-160a-70ka-tmd-trip-unit","title":"Schneider Electric C16H3TM160 ComPacT NSX MCCB NSX160H 3P 160A 70kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16H3TM160 is a ComPacT NSX NSX160H molded case circuit breaker rated 160A, 3-pole, with 70 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16H3TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160H – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16H3TM160?\u003c\/h3\u003e\u003cp\u003eThe C16H3TM160 (NSX160H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16H3TM160 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C16H3TM160 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577456925,"sku":"C16H3TM160","price":20884.99,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_09d8e5d3-503c-4a8a-9bf4-0f653c9b44c8.webp?v=1779981939"},{"product_id":"schneider-electric-c16n3tm160-compact-nsx-mccb-nsx160n-3p-160a-50ka-tmd-trip-unit","title":"Schneider Electric C16N3TM160 ComPacT NSX MCCB NSX160N 3P 160A 50kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C16N3TM160 is a ComPacT NSX NSX160N molded case circuit breaker rated 160A, 3-pole, with 50 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for sub-main feeders, distribution boards, pump and HVAC panels and building risers in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC16N3TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX160N – 160 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C16N3TM160?\u003c\/h3\u003e\u003cp\u003eThe C16N3TM160 (NSX160N) has a breaking capacity of 50 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C16N3TM160 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C16N3TM160 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577522461,"sku":"C16N3TM160","price":19356.06,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c25b3tm200-compact-nsx-mccb-nsx250b-3p-200a-25ka-tmd-trip-unit","title":"Schneider Electric C25B3TM200 ComPacT NSX MCCB NSX250B 3P 200A 25kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25B3TM200 is a ComPacT NSX NSX250B molded case circuit breaker rated 200A, 3-pole, with 25 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 25 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25B3TM200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250B – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25B3TM200?\u003c\/h3\u003e\u003cp\u003eThe C25B3TM200 (NSX250B) has a breaking capacity of 25 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25B3TM200 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C25B3TM200, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577555229,"sku":"C25B3TM200","price":19348.09,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c25b3tm250-compact-nsx-mccb-nsx250b-3p-250a-25ka-tmd-trip-unit","title":"Schneider Electric C25B3TM250 ComPacT NSX MCCB NSX250B 3P 250A 25kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25B3TM250 is a ComPacT NSX NSX250B molded case circuit breaker rated 250A, 3-pole, with 25 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 25 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25B3TM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250B – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25B3TM250?\u003c\/h3\u003e\u003cp\u003eThe C25B3TM250 (NSX250B) has a breaking capacity of 25 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25B3TM250 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C25B3TM250 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577587997,"sku":"C25B3TM250","price":20655.5,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c25f3tm160-compact-nsx-mccb-nsx250f-3p-160a-36ka-tmd-trip-unit","title":"Schneider Electric C25F3TM160 ComPacT NSX MCCB NSX250F 3P 160A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25F3TM160 is a ComPacT NSX NSX250F molded case circuit breaker rated 160A, 3-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25F3TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250F – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25F3TM160?\u003c\/h3\u003e\u003cp\u003eThe C25F3TM160 (NSX250F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25F3TM160 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C25F3TM160 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577653533,"sku":"C25F3TM160","price":22313.69,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c25f3tm200-compact-nsx-mccb-nsx250f-3p-200a-36ka-tmd-trip-unit","title":"Schneider Electric C25F3TM200 ComPacT NSX MCCB NSX250F 3P 200A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25F3TM200 is a ComPacT NSX NSX250F molded case circuit breaker rated 200A, 3-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25F3TM200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250F – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25F3TM200?\u003c\/h3\u003e\u003cp\u003eThe C25F3TM200 (NSX250F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25F3TM200 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C25F3TM200, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577817373,"sku":"C25F3TM200","price":22760.12,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c25f3tm250-compact-nsx-mccb-nsx250f-3p-250a-36ka-tmd-trip-unit","title":"Schneider Electric C25F3TM250 ComPacT NSX MCCB NSX250F 3P 250A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25F3TM250 is a ComPacT NSX NSX250F molded case circuit breaker rated 250A, 3-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25F3TM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250F – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25F3TM250?\u003c\/h3\u003e\u003cp\u003eThe C25F3TM250 (NSX250F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25F3TM250 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C25F3TM250 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577850141,"sku":"C25F3TM250","price":24290.74,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c25f4tm250-compact-nsx-mccb-nsx250f-4p-250a-36ka-tmd-trip-unit","title":"Schneider Electric C25F4TM250 ComPacT NSX MCCB NSX250F 4P 250A 36kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25F4TM250 is a ComPacT NSX NSX250F molded case circuit breaker rated 250A, 4-pole, with 36 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e4-pole version for three-phase + neutral networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25F4TM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250F – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P\/4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25F4TM250?\u003c\/h3\u003e\u003cp\u003eThe C25F4TM250 (NSX250F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25F4TM250 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C25F4TM250 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577882909,"sku":"C25F4TM250","price":34343.64,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C16H4TM160-image_web.jpg?v=1779982144"},{"product_id":"schneider-electric-c25h3tm200-compact-nsx-mccb-nsx250h-3p-200a-70ka-tmd-trip-unit","title":"Schneider Electric C25H3TM200 ComPacT NSX MCCB NSX250H 3P 200A 70kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25H3TM200 is a ComPacT NSX NSX250H molded case circuit breaker rated 200A, 3-pole, with 70 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25H3TM200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250H – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25H3TM200?\u003c\/h3\u003e\u003cp\u003eThe C25H3TM200 (NSX250H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25H3TM200 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C25H3TM200 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577915677,"sku":"C25H3TM200","price":27970.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c25h3tm250-compact-nsx-mccb-nsx250h-3p-250a-70ka-tmd-trip-unit","title":"Schneider Electric C25H3TM250 ComPacT NSX MCCB NSX250H 3P 250A 70kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25H3TM250 is a ComPacT NSX NSX250H molded case circuit breaker rated 250A, 3-pole, with 70 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25H3TM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250H – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25H3TM250?\u003c\/h3\u003e\u003cp\u003eThe C25H3TM250 (NSX250H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25H3TM250 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C25H3TM250 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263577981213,"sku":"C25H3TM250","price":27970.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_09d8e5d3-503c-4a8a-9bf4-0f653c9b44c8.webp?v=1779981939"},{"product_id":"schneider-electric-c25n3tm250-compact-nsx-mccb-nsx250n-3p-250a-50ka-tmd-trip-unit","title":"Schneider Electric C25N3TM250 ComPacT NSX MCCB NSX250N 3P 250A 50kA TMD | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25N3TM250 is a ComPacT NSX NSX250N molded case circuit breaker rated 250A, 3-pole, with 50 kA breaking capacity and a TM-D thermal-magnetic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTm-d thermal-magnetic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC25N3TM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX250N – 250 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTM-D thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C25N3TM250?\u003c\/h3\u003e\u003cp\u003eThe C25N3TM250 (NSX250N) has a breaking capacity of 50 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C25N3TM250 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C25N3TM250, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263578013981,"sku":"C25N3TM250","price":26230.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/s-l1600_534e3965-122c-4bbf-b7f8-bcd2f675d962.webp?v=1779981874"},{"product_id":"schneider-electric-c40f32d400-compact-nsx-mccb-nsx400f-3p-400a-36ka-micrologic-2-3-trip-unit","title":"Schneider Electric C40F32D400 ComPacT NSX MCCB NSX400F 3P 400A 36kA MicroLogic | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40F32D400 is a ComPacT NSX NSX400F molded case circuit breaker rated 400A, 3-pole, with 36 kA breaking capacity and a MicroLogic 2.3 electronic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMicrologic 2.3 electronic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC40F32D400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX400F – 400 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMicroLogic 2.3 electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C40F32D400?\u003c\/h3\u003e\u003cp\u003eThe C40F32D400 (NSX400F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C40F32D400 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C40F32D400, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263578046749,"sku":"C40F32D400","price":40202.9,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C40H32D400-_400_70_415_3_NSX400H.jpg?v=1779984040"},{"product_id":"schneider-electric-c40h32d400-compact-nsx-mccb-nsx400h-3p-400a-70ka-micrologic-2-3-trip-unit","title":"Schneider Electric C40H32D400 ComPacT NSX MCCB NSX400H 3P 400A 70kA MicroLogic | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40H32D400 is a ComPacT NSX NSX400H molded case circuit breaker rated 400A, 3-pole, with 70 kA breaking capacity and a MicroLogic 2.3 electronic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMicrologic 2.3 electronic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC40H32D400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX400H – 400 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMicroLogic 2.3 electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C40H32D400?\u003c\/h3\u003e\u003cp\u003eThe C40H32D400 (NSX400H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C40H32D400 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric C40H32D400 from Spark Egypt and receive an original molded case circuit breaker (MCCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263578079517,"sku":"C40H32D400","price":50580.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C40H32D400-_400_70_415_3_NSX400H.jpg?v=1779984040"},{"product_id":"schneider-electric-c40n32d400-compact-nsx-mccb-nsx400n-3p-400a-50ka-micrologic-2-3-trip-unit","title":"Schneider Electric C40N32D400 ComPacT NSX MCCB NSX400N 3P 400A 50kA MicroLogic | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40N32D400 is a ComPacT NSX NSX400N molded case circuit breaker rated 400A, 3-pole, with 50 kA breaking capacity and a MicroLogic 2.3 electronic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMicrologic 2.3 electronic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC40N32D400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX400N – 400 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMicroLogic 2.3 electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C40N32D400?\u003c\/h3\u003e\u003cp\u003eThe C40N32D400 (NSX400N) has a breaking capacity of 50 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C40N32D400 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric C40N32D400 molded case circuit breaker (MCCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263578177821,"sku":"C40N32D400","price":44659.26,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C40H32D400-_400_70_415_3_NSX400H.jpg?v=1779984040"},{"product_id":"schneider-electric-c63f32d630-compact-nsx-mccb-nsx630f-3p-630a-36ka-micrologic-2-3-trip-unit","title":"Schneider Electric C63F32D630 ComPacT NSX MCCB NSX630F 3P 630A 36kA MicroLogic | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C63F32D630 is a ComPacT NSX NSX630F molded case circuit breaker rated 630A, 3-pole, with 36 kA breaking capacity and a MicroLogic 2.3 electronic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMicrologic 2.3 electronic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 36 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC63F32D630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX630F – 630 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e36 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMicroLogic 2.3 electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C63F32D630?\u003c\/h3\u003e\u003cp\u003eThe C63F32D630 (NSX630F) has a breaking capacity of 36 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C63F32D630 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C63F32D630, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263578210589,"sku":"C63F32D630","price":57462.32,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C63F32D630-compact-nsx630-schneider-electric.jpg?v=1779985326"},{"product_id":"schneider-electric-c63h32d630-compact-nsx-mccb-nsx630h-3p-630a-70ka-micrologic-2-3-trip-unit","title":"Schneider Electric C63H32D630 ComPacT NSX MCCB NSX630H 3P 630A 70kA MicroLogic | Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C63H32D630 is a ComPacT NSX NSX630H molded case circuit breaker rated 630A, 3-pole, with 70 kA breaking capacity and a MicroLogic 2.3 electronic trip unit. It provides reliable overload and short-circuit protection for main incomers, generator and transformer outgoing feeders, sub-main distribution and motor feeders in commercial, residential and industrial low-voltage installations.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMicrologic 2.3 electronic protection with adjustable overload setting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 70 kA for installations with high fault levels\u003c\/li\u003e\n\u003cli\u003e3-pole version for three-phase networks\u003c\/li\u003e\n\u003cli\u003ePositive contact indication and suitable for isolation\u003c\/li\u003e\n\u003cli\u003eWide range of accessories: auxiliary contacts, shunt and undervoltage releases, rotary handles\u003c\/li\u003e\n\u003cli\u003eCompact frame that fits standard switchboards and panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC63H32D630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMolded case circuit breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel \/ frame\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eNSX630H – 630 A frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P\/3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity (Icu)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e70 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTrip unit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMicroLogic 2.3 electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eup to 415\/440 V AC (see datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eFixed, front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards (MDB \/ SMDB)\u003c\/li\u003e\n\u003cli\u003eTransformer, generator and ATS panels\u003c\/li\u003e\n\u003cli\u003ePump, HVAC, chiller and elevator feeders\u003c\/li\u003e\n\u003cli\u003eFactories, malls, hospitals, towers and data centres\u003c\/li\u003e\n\u003cli\u003eReplacement of old MCCBs in existing switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eChoose the rated current according to the cable and the load, the breaking capacity (Icu) higher than the prospective short-circuit current at the installation point, and the number of poles according to the earthing system. Use 4-pole breakers where the neutral must be switched or protected, and check discrimination with downstream MCBs.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the breaking capacity of the C63H32D630?\u003c\/h3\u003e\u003cp\u003eThe C63H32D630 (NSX630H) has a breaking capacity of 70 kA at 380\/415 V AC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between MCCB and MCB?\u003c\/h3\u003e\u003cp\u003eMCCBs cover higher currents (typically 16 A to 1600 A), higher breaking capacities and often adjustable protection, while MCBs are used for final circuits up to 125 A.\u003c\/p\u003e\u003ch3\u003eWhich accessories fit this breaker?\u003c\/h3\u003e\u003cp\u003eComPacT NSX breakers accept auxiliary\/alarm contacts, shunt (MX) and undervoltage (MN) releases, rotary handles and terminal shields from the same range.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider C63H32D630 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric molded case circuit breaker (MCCB)s such as the C63H32D630, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263578243357,"sku":"C63H32D630","price":71493.07,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/C63H32D630-compact-nsx630-schneider-electric.jpg?v=1779985349"}],"url":"https:\/\/www.spark-eshop.com\/collections\/application-power-monitoring-applications.oembed?page=22","provider":"Spark","version":"1.0","type":"link"}