{"title":"Application - Panel Building Applications","description":null,"products":[{"product_id":"schneider-electric-29450-auxiliary-contact-1-oc-or-1-sd-or-1-sde-or-1-sdv-default-title","title":"Schneider Electric 29450 Acti9 OF\/SD Auxiliary Contact 1 C\/O (OC \/ SD \/ SDE \/ SDV)","description":"\u003cp\u003eThe Schneider Electric 29450 is an original Acti9 auxiliary contact (1 C\/O) for Acti9 iC60, iID, iSW-NA and compatible modular devices. It adds extra control and signalling contacts for interlocking, self-holding (latching) circuits, indicator lamps and PLC status inputs.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 C\/O contact configuration\u003c\/li\u003e\n\u003cli\u003eClip-on mounting without tools\u003c\/li\u003e\n\u003cli\u003eReliable low-level switching for PLC inputs\u003c\/li\u003e\n\u003cli\u003eOriginal Schneider Electric accessory – guaranteed fit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e29450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eAccessory type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAuxiliary contact block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eContacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eside mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCompatible with\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60, iID, iSW-NA and compatible modular devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDescription\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eauxiliary contact - 1 OC or 1 SD or 1 SDE or 1 SDV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-holding (start\/stop) motor control circuits\u003c\/li\u003e\n\u003cli\u003eElectrical interlocks for reversing and star-delta starters\u003c\/li\u003e\n\u003cli\u003eStatus signalling to PLC, SCADA and BMS\u003c\/li\u003e\n\u003cli\u003eIndicator lamps on panel doors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 29450 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric 29450 auxiliary contact block with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263558385949,"sku":"29450","price":2635.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_16dbcda5-5713-4ee4-98d6-e5780e402bd7.jpg?v=1791711052"},{"product_id":"schneider-electric-3dm2-wrduwz-eocr-digital-motor-protection-relay-0-5-60a-100-240vac-dc","title":"Schneider Electric 3DM2-WRDUWZ EOCR-3DM2 Digital Motor Protection Relay 0.5–60 A 100–240V AC\/DC","description":"\u003cp\u003eThe Schneider Electric 3DM2-WRDUWZ is an EOCR-3DM2 electronic motor protection relay with a 0.5–60 A current range. Unlike bimetal overloads, it measures current electronically for accurate, repeatable protection of pumps, compressors and fans against overload, phase loss and locked rotor.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate electronic current measurement\u003c\/li\u003e\n\u003cli\u003eIndependent time settings for start and operation\u003c\/li\u003e\n\u003cli\u003eFault indication for fast troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3DM2-WRDUWZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eEOCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eElectronic overcurrent \/ motor protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCurrent range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.5–60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSupply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProtections\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eOvercurrent, phase loss, locked rotor, undercurrent, unbalance, reverse phase (digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSubmersible and booster pumps\u003c\/li\u003e\n\u003cli\u003eCompressors and chillers\u003c\/li\u003e\n\u003cli\u003eFans and conveyors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 3DM2-WRDUWZ in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric electronic motor protection relays such as the 3DM2-WRDUWZ, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263558418717,"sku":"3DM2-WRDUWZ","price":15390.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_11b65d7a-0d30-4991-b4ab-02b09001d69a.jpg?v=1791711005"},{"product_id":"schneider-50437-vigirex-closed-toroid-ta30-30mm","title":"Schneider Electric 50437 Vigirex Closed Toroid TA30 Ø30 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50437 is a Vigirex closed toroid with a 30 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50437\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eTA30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50437 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric 50437 closed toroid (residual current sensor) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560286493,"sku":"50437","price":10567.8,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_ffaf0d93-100f-49ae-88bf-7b8bd5aa329f.png?v=1780589851"},{"product_id":"schneider-50438-vigirex-closed-toroid-pa50-50mm","title":"Schneider Electric 50438 Vigirex Closed Toroid PA50 Ø50 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50438 is a Vigirex closed toroid with a 50 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50438\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ePA50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50438 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric closed toroid (residual current sensor)s such as the 50438, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560352029,"sku":"50438","price":13800.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_bdcbc394-f172-434e-8525-b2d5107b709d.png?v=1780589894"},{"product_id":"schneider-electric-50439-closed-toroid-for-residual-current-protection-ia-80-mm-default-title","title":"Schneider Electric 50439 Vigirex Closed Toroid IA Ø80 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50439 is a Vigirex closed toroid with a 80 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50439 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric closed toroid (residual current sensor)s such as the 50439, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560384797,"sku":"50439","price":17390.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_18e79133-b5d6-42dd-a39e-3187bcd63bf7.jpg?v=1791710905"},{"product_id":"schneider-electric-50440-closed-toroid-for-residual-current-protection-ma-120-mm-default-title","title":"Schneider Electric 50440 Vigirex Closed Toroid MA Ø120 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50440 is a Vigirex closed toroid with a 120 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50440 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 50440 from Spark Egypt and receive an original closed toroid (residual current sensor) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560450333,"sku":"50440","price":22930.01,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_f1fe5dce-2256-4fbe-8c19-8ee49a96be19.png?v=1780589977"},{"product_id":"schneider-50441-vigirex-closed-toroid-sa200-200mm","title":"Schneider Electric 50441 Vigirex Closed Toroid SA200 Ø200 mm | Residual Current Sensor","description":"\u003cp\u003eThe Schneider Electric 50441 is a Vigirex closed toroid with a 200 mm inner diameter. All live conductors pass through it so it detects residual (earth-leakage) current and feeds the signal to a Vigirex RH relay, which trips the associated breaker.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAccurate residual current sensing\u003c\/li\u003e\n\u003cli\u003eChoose the diameter according to cable bundle size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50441\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eClosed toroid (core balance CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eInner diameter\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eFor relays\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH earth-leakage relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection of large feeders with MCCB\/ACB\u003c\/li\u003e\n\u003cli\u003eFire protection in industrial plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 50441 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 50441 from Spark Egypt and receive an original closed toroid (residual current sensor) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560548637,"sku":"50441","price":33600.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_09cd67ac-083f-4639-ad73-c7be7032bcab.jpg?v=1791710607"},{"product_id":"schneider-51207-varlogic-power-factor-controller-6-steps","title":"Schneider Electric 51207 Varlogic Power Factor Controller 6 Steps","description":"\u003cp\u003eThe Schneider Electric 51207 is a Varlogic automatic power factor controller with 6 steps. It measures the network power factor and switches capacitor-bank steps in and out through capacitor contactors to keep the target cos φ.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic step switching with configurable target power factor\u003c\/li\u003e\n\u003cli\u003eDisplay of cos φ and alarms\u003c\/li\u003e\n\u003cli\u003ePanel-door mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e51207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAutomatic power factor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of steps\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAPFC panels\u003c\/li\u003e\n\u003cli\u003eFactories and commercial buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 51207 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 51207 from Spark Egypt and receive an original power factor controller with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560581405,"sku":"51207","price":9337.45,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/ODA51207_web-1_jpg.webp?v=1791326734"},{"product_id":"schneider-51213-varlogic-power-factor-controller-12-steps","title":"Schneider Electric 51213 Varlogic Power Factor Controller 12 Steps","description":"\u003cp\u003eThe Schneider Electric 51213 is a Varlogic automatic power factor controller with 12 steps. It measures the network power factor and switches capacitor-bank steps in and out through capacitor contactors to keep the target cos φ.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic step switching with configurable target power factor\u003c\/li\u003e\n\u003cli\u003eDisplay of cos φ and alarms\u003c\/li\u003e\n\u003cli\u003ePanel-door mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e51213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAutomatic power factor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of steps\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVarlogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAPFC panels\u003c\/li\u003e\n\u003cli\u003eFactories and commercial buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 51213 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 51213 from Spark Egypt and receive an original power factor controller with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560646941,"sku":"51213","price":14834.25,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/l-3_jpg.webp?v=1791326836"},{"product_id":"schneider-56173-vigirex-rh99m-earth-leakage-relay-manual-reset","title":"Schneider Electric 56173 Vigirex RH99M Earth-Leakage Relay 0.03–30A 0–4.5s 240V Manual Reset","description":"\u003cp\u003eThe Schneider Electric 56173 is a Vigirex RH99M earth-leakage relay with adjustable sensitivity (0.03–30 A) and time delay (0–4.5 s), manual reset. Combined with a Vigirex toroid and the shunt trip of an MCCB or ACB, it provides adjustable earth-leakage protection for large feeders where RCCBs are not available.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable sensitivity and time delay for selectivity\u003c\/li\u003e\n\u003cli\u003eFault and pre-alarm indication\u003c\/li\u003e\n\u003cli\u003eWorks with any breaker equipped with a shunt trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e56173\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH99M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eEarth-leakage protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.03 – 30 A adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0 – 4.5 s adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSupply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReset\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain incomers and large feeders\u003c\/li\u003e\n\u003cli\u003eIndustrial plants and hospitals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 56173 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric earth-leakage relays such as the 56173, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560679709,"sku":"56173","price":24930.43,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/PB100429_SE_369.jpg?v=1791710565"},{"product_id":"schneider-56193-vigirex-rh99m-earth-leakage-relay-auto-reset","title":"Schneider Electric 56193 Vigirex RH99M Earth-Leakage Relay 0.03–30A 0–4.5s 240V Automatic Reset","description":"\u003cp\u003eThe Schneider Electric 56193 is a Vigirex RH99M earth-leakage relay with adjustable sensitivity (0.03–30 A) and time delay (0–4.5 s), automatic reset. Combined with a Vigirex toroid and the shunt trip of an MCCB or ACB, it provides adjustable earth-leakage protection for large feeders where RCCBs are not available.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable sensitivity and time delay for selectivity\u003c\/li\u003e\n\u003cli\u003eFault and pre-alarm indication\u003c\/li\u003e\n\u003cli\u003eWorks with any breaker equipped with a shunt trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e56193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eVigirex RH99M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eEarth-leakage protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0.03 – 30 A adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTime delay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e0 – 4.5 s adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSupply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eReset\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain incomers and large feeders\u003c\/li\u003e\n\u003cli\u003eIndustrial plants and hospitals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 56193 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 56193 from Spark Egypt and receive an original earth-leakage relay with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560745245,"sku":"56193","price":24937.73,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/56193-25.jpg?v=1791710303"},{"product_id":"schneider-59642-sepam-ace949-2-rs485-interface-module","title":"Schneider Electric 59642 ACE949-2 RS485 Interface Module for Sepam Series 20\/40\/60\/80 – Modbus RTU Communication","description":"\u003cp\u003eThe Schneider Electric 59642 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: ACE949-2 RS485 Interface Module for Sepam Series 20\/40\/60\/80 – Modbus RTU Communication. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59642\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eACE949-2 RS485 Interface Module for Sepam Series 20\/40\/60\/80 – Modbus RTU Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59642 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 59642 from Spark Egypt and receive an original medium-voltage protection relay component with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560810781,"sku":"59642","price":17712.75,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_ffad2f4e-6994-49b9-a8a1-f68ef26b02fd.jpg?v=1785582758"},{"product_id":"schneider-59704-sepam-base-unit-sep383-for-sepam-series-80-24","title":"Schneider Electric 59704 base unit SEP383 for Sepam series 80 - 24…250 V - with advanced UMI","description":"\u003cp\u003eThe Schneider Electric 59704 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: base unit SEP383 for Sepam series 80 - 24…250 V - with advanced UMI. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ebase unit SEP383 for Sepam series 80 - 24…250 V - with advanced UMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59704 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric medium-voltage protection relay components such as the 59704, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560843549,"sku":"59704","price":17712.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_08d4dd9b-dc97-4a9e-ae9b-df92506712ed.jpg?v=1785582697"},{"product_id":"schneider-electric-59707-memory-cartridge-mms020-sepam-series-80-default-title","title":"Schneider Electric 59707 memory cartridge MMS020 Sepam series 80","description":"\u003cp\u003eThe Schneider Electric 59707 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: memory cartridge MMS020 Sepam series 80. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003ememory cartridge MMS020 Sepam series 80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59707 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric 59707 from Spark Egypt and receive an original medium-voltage protection relay component with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560876317,"sku":"59707","price":17712.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_1b25851d-8ecc-421d-b38f-a0ca5164b46e.jpg?v=1785582575"},{"product_id":"schneider-59715-sepam-i-o-module-mes120-sepam-series-60-80-14","title":"Schneider Electric 59715 I\/O module MES120 - Sepam series 60, 80 - 14 inputs+ 6 outputs 24...250V DC","description":"\u003cp\u003eThe Schneider Electric 59715 belongs to the Sepam family of digital protection relays used in medium-voltage switchgear: I\/O module MES120 - Sepam series 60, 80 - 14 inputs+ 6 outputs 24...250V DC. It is used by utilities, industrial plants and EPC contractors for feeder, transformer, motor and substation protection, metering and communication.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital protection, metering and event recording\u003c\/li\u003e\n\u003cli\u003eModbus \/ IEC communication options\u003c\/li\u003e\n\u003cli\u003eProven Schneider Electric MV platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e59715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMV digital protection relay \/ module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDetails\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eI\/O module MES120 - Sepam series 60, 80 - 14 inputs+ 6 outputs 24...250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMV switchgear and RMUs\u003c\/li\u003e\n\u003cli\u003eIndustrial substations\u003c\/li\u003e\n\u003cli\u003eUtility distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider 59715 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric medium-voltage protection relay components such as the 59715, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263560941853,"sku":"59715","price":17712.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/download_858e9136-e92a-4ad7-899c-b65711a23d3c.jpg?v=1785582518"},{"product_id":"siemens-rcbo-1pn-10ka-30ma-5su9304-1kk","title":"Siemens 5SU9304-1KK RCBO 1P+N 16–40 A C-Curve 30mA 10 kA | Earth Leakage + MCB in One","description":"\u003cp\u003eThe Siemens 5SU9304-1KK is a 1P+N 16–40 A C-curve RCBO with 30 mA earth-leakage sensitivity and 10 kA breaking capacity. It combines a miniature circuit breaker and a residual current device in one module, protecting the circuit against overload, short circuit and dangerous earth-leakage currents, and saving space in the distribution board.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload, short-circuit and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity – protection of people against electric shock\u003c\/li\u003e\n\u003cli\u003eIndividual protection per circuit – a fault trips only the affected circuit\u003c\/li\u003e\n\u003cli\u003eTest button for periodic checking\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting and compact width\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number \/ model\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e5SU9304-1KK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO (RCD + MCB in one device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16–40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61009-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAvailable versions\u003c\/h2\u003e\u003cp\u003eCurrent: 16A, 20A, 25A, 32A, 40A.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eIndividual protection of air-conditioner and socket circuits\u003c\/li\u003e\n\u003cli\u003eVillas, apartments, clinics and offices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection and installation tips\u003c\/h2\u003e\u003cp\u003eChoose the RCBO rating according to the cable size of the circuit, as for an MCB, and use 30 mA sensitivity for socket and wet-area circuits. Using an RCBO per circuit avoids total blackout of the apartment when one appliance leaks.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between an RCBO and an RCCB?\u003c\/h3\u003e\u003cp\u003eAn RCCB only detects earth leakage; an RCBO adds overload and short-circuit protection, so it can replace an MCB + RCCB combination for a single circuit.\u003c\/p\u003e\u003ch3\u003eWhere is the Siemens 5SU9304-1KK typically installed?\u003c\/h3\u003e\u003cp\u003eOn circuits feeding water heaters, bathrooms, kitchens, outdoor sockets and air conditioners where both overcurrent and shock protection are needed.\u003c\/p\u003e\n\u003ch2\u003eBuy Siemens 5SU9304-1KK in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Siemens 5SU9304-1KK residual current breaker with overcurrent protection (RCBO) from Spark Egypt and receive a genuine product with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, installers and maintenance teams check ratings, accessories and cross-references before purchase. Request a quotation for bulk or project quantities.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"16A","offer_id":51320030527773,"sku":"5SU9304-1KK16","price":3441.75,"currency_code":"EGP","in_stock":false},{"title":"20A","offer_id":51320030560541,"sku":"5SU9304-1KK20","price":3536.25,"currency_code":"EGP","in_stock":true},{"title":"25A","offer_id":51320030593309,"sku":"5SU9304-1KK25","price":3687.0,"currency_code":"EGP","in_stock":false},{"title":"32A","offer_id":51320030626077,"sku":"5SU9304-1KK32","price":3816.75,"currency_code":"EGP","in_stock":false},{"title":"40A","offer_id":51320030658845,"sku":"5SU9304-1KK40","price":3924.75,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/02_10_2025_11_33_20_5SU9304_7KK10.jpg?v=1779461208"},{"product_id":"schneider-a9a26476-acti9-imx-shunt-trip-100-415v","title":"Schneider Electric A9A26476 Acti9 iMX Shunt Trip Release 100–415V AC for iC60 \/ iID","description":"\u003cp\u003eThe Schneider Electric A9A26476 is an Acti9 iMX shunt trip that opens the associated MCB or RCCB remotely when a voltage signal is applied – used for emergency stop, fire-alarm shutdown and remote load shedding.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOriginal Acti9 modular accessory\u003c\/li\u003e\n\u003cli\u003eClip-on assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9A26476\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iMX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eShunt trip (voltage release)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCompatible with\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60, iID and compatible devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDistribution boards\u003c\/li\u003e\n\u003cli\u003eEmergency and BMS-controlled circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9A26476 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9A26476 shunt trip release with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263561859357,"sku":"A9A26476","price":2793.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/7556_A9A26476_1500.jpg?v=1791710201"},{"product_id":"schneider-electric-a9a26924-auxiliary-contact-acti9-iof-1-oc-ac-dc-default-title","title":"Schneider Electric A9A26924 Acti9 iOF Auxiliary Contact 1 OC","description":"\u003cp\u003eThe Schneider Electric A9A26924 is an original Acti9 auxiliary contact (1 OC) for Acti9 iC60, iID, iSW-NA and compatible modular devices. It adds extra control and signalling contacts for interlocking, self-holding (latching) circuits, indicator lamps and PLC status inputs.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 OC contact configuration\u003c\/li\u003e\n\u003cli\u003eClip-on mounting without tools\u003c\/li\u003e\n\u003cli\u003eReliable low-level switching for PLC inputs\u003c\/li\u003e\n\u003cli\u003eOriginal Schneider Electric accessory – guaranteed fit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9A26924\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eAccessory type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAuxiliary contact block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eContacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1 OC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eside mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCompatible with\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60, iID, iSW-NA and compatible modular devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDescription\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eauxiliary contact, Acti9, iOF, 1 OC, AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-holding (start\/stop) motor control circuits\u003c\/li\u003e\n\u003cli\u003eElectrical interlocks for reversing and star-delta starters\u003c\/li\u003e\n\u003cli\u003eStatus signalling to PLC, SCADA and BMS\u003c\/li\u003e\n\u003cli\u003eIndicator lamps on panel doors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9A26924 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric auxiliary contact blocks such as the A9A26924, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263561892125,"sku":"A9A26924","price":1025.1,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/61011_A9A26924_1500.jpg?v=1791710153"},{"product_id":"schneider-electric-a9a26929-auxiliary-contact-acti9-iof-sd-plus-of-2oc-ac-dc-default-title","title":"Schneider Electric A9A26929 Acti9 iOF\/SD+OF Auxiliary Contact 2OC","description":"\u003cp\u003eThe Schneider Electric A9A26929 is an original Acti9 auxiliary contact (2OC) for Acti9 iC60, iID, iSW-NA and compatible modular devices. It adds extra control and signalling contacts for interlocking, self-holding (latching) circuits, indicator lamps and PLC status inputs.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2OC contact configuration\u003c\/li\u003e\n\u003cli\u003eClip-on mounting without tools\u003c\/li\u003e\n\u003cli\u003eReliable low-level switching for PLC inputs\u003c\/li\u003e\n\u003cli\u003eOriginal Schneider Electric accessory – guaranteed fit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9A26929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eAccessory type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eAuxiliary contact block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eContacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2OC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eside mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCompatible with\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60, iID, iSW-NA and compatible modular devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDescription\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eauxiliary contact, Acti9, iOF\/SD+OF, 2OC, AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelf-holding (start\/stop) motor control circuits\u003c\/li\u003e\n\u003cli\u003eElectrical interlocks for reversing and star-delta starters\u003c\/li\u003e\n\u003cli\u003eStatus signalling to PLC, SCADA and BMS\u003c\/li\u003e\n\u003cli\u003eIndicator lamps on panel doors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9A26929 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9A26929 from Spark Egypt and receive an original auxiliary contact block with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263561924893,"sku":"A9A26929","price":1555.59,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/2023-11-04-65460193c637a_vdt37hpju59rqb8q.jpg?v=1791710065"},{"product_id":"schneider-a9c20731-acti9-ict-contactor-25a-1p-1no-230-240vac","title":"Schneider Electric A9C20731 Acti9 iCT Modular Contactor 1P 25A 1NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20731 is an Acti9 iCT 1-pole, 25 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20731\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P, 1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20731 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric modular contactors such as the A9C20731, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562023197,"sku":null,"price":1336.5,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20731_SchneiderActi9iCTContactor25A_1-Pole_1NO_230-240VAC_50Hz_f6ca9b04-4536-4629-85d5-daa446211e73.jpg?v=1779576424"},{"product_id":"schneider-electric-acti9-ict-silent-contactor-25a-2no-a9c20732","title":"Schneider Electric A9C20732 Acti9 iCT Modular Contactor 2P 25A 2NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20732 is an Acti9 iCT 2-pole, 25 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20732\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P, 2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20732 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9C20732 modular contactor with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562055965,"sku":"A9C20732","price":1481.44,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20732_SchneiderActi9iCTSilentContactor_25A_2-Pole_2NO_230-240VAC.jpg?v=1779574762"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-25a-3no-a9c20833","title":"Schneider Electric A9C20833 Acti9 iCT Modular Contactor 3P 25A 3NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20833 is an Acti9 iCT 3-pole, 25 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20833 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9C20833 modular contactor with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562088733,"sku":"A9C20833","price":1751.95,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20833_SchneiderActi9iCTContactor25A_3-Pole_3NO_220-240VAC_50Hz.jpg?v=1779574420"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-25a-4no-a9c20834","title":"Schneider Electric A9C20834 Acti9 iCT Modular Contactor 4P 25A 4NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20834 is an Acti9 iCT 4-pole, 25 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20834\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20834 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9C20834 modular contactor with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562121501,"sku":null,"price":2418.51,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20834_SchneiderActi9iCTContactor25A_4-Pole_4NO_220-240VAC_3-Phase_Neutral.jpg?v=1779572664"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-40a-2no-a9c20842","title":"Schneider Electric A9C20842 Acti9 iCT Modular Contactor 2P 40A 2NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20842 is an Acti9 iCT 2-pole, 40 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P, 2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20842 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9C20842 from Spark Egypt and receive an original modular contactor with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562154269,"sku":"A9C20842","price":2474.97,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20842_SchneiderElectricSilentContactor2P-2NO-40A-220--240VACiCT.jpg?v=1779570829"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-40a-4no-a9c20844","title":"Schneider Electric A9C20844 Acti9 iCT Modular Contactor 4P 40A 4NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20844 is an Acti9 iCT 4-pole, 40 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20844 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9C20844 from Spark Egypt and receive an original modular contactor with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562219805,"sku":"A9C20844","price":4929.59,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20844_ContactoriCT-4poles-4NO-40A-220--240VAC.jpg?v=1779570234"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-63a-2no-a9c20862","title":"Schneider Electric A9C20862 Acti9 iCT Modular Contactor 2P 63A 2NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20862 is an Acti9 iCT 2-pole, 63 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20862\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P, 2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20862 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9C20862 modular contactor with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562252573,"sku":"A9C20862","price":3847.5,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20862_iCT63A2NO220--.240V50HzContactor.jpg?v=1779569860"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-63a-3no-a9c20863","title":"Schneider Electric A9C20863 Acti9 iCT Modular Contactor 3P 63A 3NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20863 is an Acti9 iCT 3-pole, 63 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20863\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20863 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9C20863 modular contactor with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562318109,"sku":null,"price":5416.08,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20863_iCT63A3NO220--.240V50HzContactor.jpg?v=1779568850"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-63a-4no-a9c20864","title":"Schneider Electric A9C20864 Acti9 iCT Modular Contactor 4P 63A 4NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20864 is an Acti9 iCT 4-pole, 63 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20864\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20864 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric modular contactors such as the A9C20864, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562350877,"sku":"A9C20864","price":7417.07,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20864_iCT63A4NO220--.240V50HzContactor.jpg?v=1779566896"},{"product_id":"schneider-electric-acti9-ict-modular-contactor-100a-4no-a9c20884","title":"Schneider Electric A9C20884 Acti9 iCT Modular Contactor 4P 100A 4NO 230V AC Coil | Silent DIN-Rail Contactor","description":"\u003cp\u003eThe Schneider Electric A9C20884 is an Acti9 iCT 4-pole, 100 A modular contactor with a 230 V AC coil. Designed for silent switching in residential and commercial buildings, it remotely controls lighting, water heaters, under-floor heating, pumps and HVAC loads from timers, sensors, BMS outputs or push buttons.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSilent operation – ideal for homes, hotels, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eModular 18 mm-multiple width, fits standard distribution boards\u003c\/li\u003e\n\u003cli\u003eManual override and status indicator (on relevant versions)\u003c\/li\u003e\n\u003cli\u003eLong life for frequent switching of lighting and heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C20884\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eModular (DIN-rail) contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles \/ contacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (AC-7a)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSilent (humless) operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 61095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control by timers and photocells\u003c\/li\u003e\n\u003cli\u003eWater heaters and storage heaters\u003c\/li\u003e\n\u003cli\u003eLoad shedding and BMS-controlled circuits\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C20884 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric modular contactors such as the A9C20884, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562416413,"sku":"A9C20884","price":7289.25,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C20882_iCT100A2NO220--.240V50HzContactor.jpg?v=1779566679"},{"product_id":"schneider-electric-acti9-itl-impulse-relay-16a-a9c30811","title":"Schneider Electric A9C30811 Acti9 iTL Impulse Relay 1P 1NO 16A 230V AC Coil | Latching Lighting Relay","description":"\u003cp\u003eThe Schneider Electric A9C30811 is an Acti9 iTL impulse relay (1NO, 16 A) that switches a lighting circuit ON and OFF with each short pulse from any number of push buttons – the simplest way to control corridor, staircase, warehouse and large-room lighting from several points.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eControl from unlimited push buttons connected in parallel\u003c\/li\u003e\n\u003cli\u003eSaves cabling compared with two-way\/intermediate switches\u003c\/li\u003e\n\u003cli\u003eManual operation and position indication on the front\u003c\/li\u003e\n\u003cli\u003eSilent, low-consumption coil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C30811\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eImpulse (latching) relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eContacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCorridors, staircases and lobbies\u003c\/li\u003e\n\u003cli\u003eWarehouses, workshops and car parks\u003c\/li\u003e\n\u003cli\u003eLarge halls, villas and hotels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C30811 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric impulse relays such as the A9C30811, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562514717,"sku":"A9C30811","price":1900.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C30811_impulserelayiTL-1P-1NO-16A-coil110VDC-230--.240VAC50-60Hz.jpg?v=1779556198"},{"product_id":"schneider-electric-acti9-itl-impulse-relay-16a-a9c30812","title":"Schneider Electric A9C30812 Acti9 iTL Impulse Relay 2P 2NO 16A 230V AC Coil | Latching Lighting Relay","description":"\u003cp\u003eThe Schneider Electric A9C30812 is an Acti9 iTL impulse relay (2NO, 16 A) that switches a lighting circuit ON and OFF with each short pulse from any number of push buttons – the simplest way to control corridor, staircase, warehouse and large-room lighting from several points.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eControl from unlimited push buttons connected in parallel\u003c\/li\u003e\n\u003cli\u003eSaves cabling compared with two-way\/intermediate switches\u003c\/li\u003e\n\u003cli\u003eManual operation and position indication on the front\u003c\/li\u003e\n\u003cli\u003eSilent, low-consumption coil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C30812\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eImpulse (latching) relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eContacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCorridors, staircases and lobbies\u003c\/li\u003e\n\u003cli\u003eWarehouses, workshops and car parks\u003c\/li\u003e\n\u003cli\u003eLarge halls, villas and hotels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C30812 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9C30812 impulse relay with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562547485,"sku":null,"price":2800.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C30812_impulserelayiTL-2P-2NO-16A-coil110VDC-230--.240VAC50-60Hz.jpg?v=1779556027"},{"product_id":"schneider-electric-acti9-itli-impulse-relay-16a-a9c30815","title":"Schneider Electric A9C30815 Acti9 iTL Impulse Relay 2P 1NO+1NC 16A 230V AC Coil | Latching Lighting Relay","description":"\u003cp\u003eThe Schneider Electric A9C30815 is an Acti9 iTL impulse relay (1NO+1NC, 16 A) that switches a lighting circuit ON and OFF with each short pulse from any number of push buttons – the simplest way to control corridor, staircase, warehouse and large-room lighting from several points.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eControl from unlimited push buttons connected in parallel\u003c\/li\u003e\n\u003cli\u003eSaves cabling compared with two-way\/intermediate switches\u003c\/li\u003e\n\u003cli\u003eManual operation and position indication on the front\u003c\/li\u003e\n\u003cli\u003eSilent, low-consumption coil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9C30815\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eImpulse (latching) relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eContacts\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1NO+1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eCoil voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCorridors, staircases and lobbies\u003c\/li\u003e\n\u003cli\u003eWarehouses, workshops and car parks\u003c\/li\u003e\n\u003cli\u003eLarge halls, villas and hotels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9C30815 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric impulse relays such as the A9C30815, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562580253,"sku":"2,459.99","price":2459.99,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9C30815_impulserelayiTLI-2P-1NO_1NC-16A-coil110VDC-230--.240VAC50-60Hz.jpg?v=1779554457"},{"product_id":"schneider-electric-acti9-ic60h-rcbo-1pn-10ka-30ma-a9d118xx","title":"Schneider Electric A9D118 Acti9 iC60H RCBO 1P+N 10A–40A C-Curve 30mA 10kA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D118 is an Acti9 iC60H RCBO rated 10A–40A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60H RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10A–40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D118 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D118 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9D118 residual current circuit breaker with overcurrent protection (RCBO) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"A9D11810 - 10A","offer_id":51320057856285,"sku":"A9D11810","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11816 - 16A","offer_id":51320057889053,"sku":"A9D11816","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11820 - 20A","offer_id":51320057921821,"sku":"A9D11820","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11825 - 25A","offer_id":51320057954589,"sku":"A9D11825","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11832 - 32A","offer_id":51320057987357,"sku":"A9D11832","price":3650.0,"currency_code":"EGP","in_stock":true},{"title":"A9D11840 - 40A","offer_id":51320058020125,"sku":"A9D11840","price":3650.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9D11810_iC60H-earthleakagecircuitbreaker-1P_N-Ccurve-10A-30mA-240V.jpg?v=1779461268"},{"product_id":"schneider-electric-a9d31610-acti9-idpn-n-vigi-rcbo-1p-n-10a-c-curve-30ma-type-ac","title":"Schneider Electric A9D31610 Acti9 iDPN N Vigi 1P+N 10A C-Curve 30mA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D31610 is an Acti9 iDPN N Vigi RCBO rated 10A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D31610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iDPN N Vigi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D31610 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D31610 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9D31610 from Spark Egypt and receive an original residual current circuit breaker with overcurrent protection (RCBO) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263562973469,"sku":"A9D31610","price":3401.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/rn-image_picker_lib_temp_3c101176-6b5a-44bf-9747-b73aa95ba972.jpg?v=1791576386"},{"product_id":"schneider-electric-a9d31620-acti9-idpn-n-vigi-rcbo-1p-n-20a-c-curve-30ma-type-ac","title":"Schneider Electric A9D31620 Acti9 iDPN N Vigi 1P+N 20A C-Curve 30mA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D31620 is an Acti9 iDPN N Vigi RCBO rated 20A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D31620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iDPN N Vigi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D31620 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D31620 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9D31620 from Spark Egypt and receive an original residual current circuit breaker with overcurrent protection (RCBO) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563006237,"sku":"A9D31620","price":3401.53,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/rn-image_picker_lib_temp_3c101176-6b5a-44bf-9747-b73aa95ba972.jpg?v=1791576386"},{"product_id":"schneider-electric-a9d61820-acti9-ic60n-earth-leakage-circuit-breaker-1p-n-20a-30ma","title":"Schneider Electric A9D61820 Acti9 iC60N RCBO 1P+N 20A C-Curve 30mA | RCBO","description":"\u003cp\u003eThe Schneider Electric A9D61820 is an Acti9 iC60N RCBO RCBO rated 20A, C curve, 30 mA. It combines a miniature circuit breaker and an earth-leakage device in one compact module, protecting each single-phase final circuit individually against overload, short circuit and electric shock.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and earth-leakage protection in one device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity for protection of people\u003c\/li\u003e\n\u003cli\u003eA fault on one circuit does not switch off the whole board\u003c\/li\u003e\n\u003cli\u003eTest button and trip indication\u003c\/li\u003e\n\u003cli\u003eSaves space compared with a separate MCB + RCCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9D61820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRCBO – earth-leakage + overload + short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eSensitivity (IΔn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eResidual current type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBathroom, kitchen and water-heater circuits\u003c\/li\u003e\n\u003cli\u003eOutdoor sockets, gardens and swimming pools\u003c\/li\u003e\n\u003cli\u003eHotel rooms, hospitals and offices\u003c\/li\u003e\n\u003cli\u003eCritical single-phase circuits that must stay selective\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eSelect the rated current according to the circuit cable, keep 30 mA for protection of people, and use one RCBO per circuit to avoid total board shutdown when a leakage fault happens.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat does RCBO stand for?\u003c\/h3\u003e\u003cp\u003eResidual Current Breaker with Overcurrent protection – a single device that works as an MCB and an RCCB together.\u003c\/p\u003e\u003ch3\u003eCan the A9D61820 replace an MCB?\u003c\/h3\u003e\u003cp\u003eYes, on a single-phase circuit it replaces the MCB and adds earth-leakage protection in the same position.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9D61820 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9D61820 from Spark Egypt and receive an original residual current circuit breaker with overcurrent protection (RCBO) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563071773,"sku":"A9D61820","price":3255.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_3be102e4-d4af-429b-a6d1-d2ff639ac9f5.jpg?v=1791709491"},{"product_id":"schneider-electric-a9e18320-acti9-iil-single-indicator-light-red-110-230-vac-default-title","title":"Schneider Electric A9E18320 Acti9 iIL Modular Indicator Light Red 110–230V AC","description":"\u003cp\u003eThe Schneider Electric A9E18320 is an Acti9 iIL modular red indicator light (110–230 V AC) that shows the presence of voltage or the state of a circuit directly inside the distribution board.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOriginal Acti9 modular accessory\u003c\/li\u003e\n\u003cli\u003eClip-on assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9E18320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eDIN-rail indicator light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eColour\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e110–230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDistribution boards\u003c\/li\u003e\n\u003cli\u003eEmergency and BMS-controlled circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Schneider A9E18320 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9E18320 from Spark Egypt and receive an original modular indicator light with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563104541,"sku":"A9E18320","price":456.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/images_aead1601-88ec-47ad-8800-afc1cd5e0e50.jpg?v=1791709546"},{"product_id":"schneider-electric-a9f74101-acti9-ic60n-1p-1a-c-curve-50ka-mcb","title":"Schneider Electric A9F74101 Acti9 iC60N MCB 1P 1A C-Curve 50kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F74101 is a 1-pole, 1A C-curve miniature circuit breaker from the Acti9 iC60N range with 50kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F74101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F74101 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 1A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F74101 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F74101 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9F74101 miniature circuit breaker (MCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563137309,"sku":"A9F74101","price":575.22,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_ea52513d-39de-421d-8dc2-246da60fd83d.png?v=1781007242"},{"product_id":"schneider-electric-a9f74102-acti9-ic60n-1p-2a-c-curve-50ka-mcb","title":"Schneider Electric A9F74102 Acti9 iC60N MCB 1P 2A C-Curve 50kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F74102 is a 1-pole, 2A C-curve miniature circuit breaker from the Acti9 iC60N range with 50kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F74102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F74102 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 2A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F74102 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F74102 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9F74102 miniature circuit breaker (MCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563170077,"sku":"A9F74102","price":606.69,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_f84041eb-fc07-4735-bee6-26551d50b992.png?v=1781007325"},{"product_id":"schneider-electric-a9f74104-acti9-ic60n-1p-4a-c-curve-10ka-mcb","title":"Schneider Electric A9F74104 Acti9 iC60N MCB 1P 4A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F74104 is a 1-pole, 4A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F74104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F74104 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 4A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F74104 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F74104 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric miniature circuit breaker (MCB)s such as the A9F74104, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563202845,"sku":"A9F74104","price":552.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_2bf2547a-d56c-4636-aaef-fdb34488448b.png?v=1781007405"},{"product_id":"schneider-electric-a9f74202-acti9-ic60n-2p-2a-c-curve-50ka-mcb","title":"Schneider Electric A9F74202 Acti9 iC60N MCB 2P 2A C-Curve 50kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F74202 is a 2-pole, 2A C-curve miniature circuit breaker from the Acti9 iC60N range with 50kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase circuits where both phase and neutral must be disconnected, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e2-pole design for single-phase circuits where both phase and neutral must be disconnected\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F74202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F74202 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 2P 2A C-curve MCB used to protect single-phase circuits where both phase and neutral must be disconnected against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F74202 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F74202 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric miniature circuit breaker (MCB)s such as the A9F74202, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563235613,"sku":"A9F74202","price":1197.0,"currency_code":"EGP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_792db289-0c5f-4b7f-bddc-daa7f665ce51.png?v=1781007472"},{"product_id":"schneider-electric-a9f74203-acti9-ic60n-2p-3a-c-curve-50ka-mcb","title":"Schneider Electric A9F74203 Acti9 iC60N MCB 2P 3A C-Curve 50kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F74203 is a 2-pole, 3A C-curve miniature circuit breaker from the Acti9 iC60N range with 50kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase circuits where both phase and neutral must be disconnected, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e2-pole design for single-phase circuits where both phase and neutral must be disconnected\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F74203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F74203 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 2P 3A C-curve MCB used to protect single-phase circuits where both phase and neutral must be disconnected against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F74203 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F74203 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt is a trusted source for original Schneider Electric miniature circuit breaker (MCB)s such as the A9F74203, serving contractors, OEMs, panel builders and plant-maintenance teams with tax invoices and fast delivery to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Contact our technical sales team to confirm selection, accessories and project pricing.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563268381,"sku":"A9F74203","price":1194.99,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_288636d1-6f4f-4dd9-bfe9-e7f1897adacc.png?v=1781007549"},{"product_id":"schneider-electric-a9f74204-acti9-ic60n-2p-4a-c-curve-50ka-mcb","title":"Schneider Electric A9F74204 Acti9 iC60N MCB 2P 4A C-Curve 50kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F74204 is a 2-pole, 4A C-curve miniature circuit breaker from the Acti9 iC60N range with 50kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase circuits where both phase and neutral must be disconnected, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e2-pole design for single-phase circuits where both phase and neutral must be disconnected\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 50kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F74204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e50kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F74204 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 2P 4A C-curve MCB used to protect single-phase circuits where both phase and neutral must be disconnected against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F74204 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F74204 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9F74204 from Spark Egypt and receive an original miniature circuit breaker (MCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563333917,"sku":"A9F74204","price":980.4,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/files_543bd398-4068-4070-bf3f-454b9ef84b11.png?v=1781007591"},{"product_id":"schneider-electric-acti9-ic60n-mcb-1p-6a-10ka-a9f77106","title":"Schneider Electric A9F77106 Acti9 iC60N MCB 1P 6A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F77106 is a 1-pole, 6A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F77106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F77106 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 6A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F77106 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F77106 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9F77106 miniature circuit breaker (MCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563366685,"sku":null,"price":386.46,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9F77106-Miniaturecircuit-breaker_Acti9iC60N_1P_6A_Ccurve_10kASchneiderElectric.jpg?v=1779230135"},{"product_id":"schneider-electric-acti9-ic60n-mcb-1p-10a-10ka-a9f77110","title":"Schneider Electric A9F77110 Acti9 iC60N MCB 1P 10A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F77110 is a 1-pole, 10A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F77110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F77110 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 10A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F77110 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F77110 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9F77110 miniature circuit breaker (MCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563399453,"sku":null,"price":346.23,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9F77110-Miniaturecircuit-breaker_Acti9iC60N_1P_10A_Ccurve_10kASchneiderElectric.jpg?v=1779228466"},{"product_id":"schneider-electric-acti9-ic60n-mcb-1p-16a-10ka-a9f77116","title":"Schneider Electric A9F77116 Acti9 iC60N MCB 1P 16A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F77116 is a 1-pole, 16A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F77116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F77116 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 16A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F77116 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F77116 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9F77116 from Spark Egypt and receive an original miniature circuit breaker (MCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563464989,"sku":null,"price":346.23,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9F77116-Miniaturecircuit-breaker_Acti9iC60N_1P_16A_Ccurve_10kASchneiderElectric.jpg?v=1779227477"},{"product_id":"schneider-electric-acti9-ic60n-mcb-1p-20a-10ka-a9f77120","title":"Schneider Electric A9F77120 Acti9 iC60N MCB 1P 20A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F77120 is a 1-pole, 20A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F77120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F77120 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 20A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F77120 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F77120 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9F77120 miniature circuit breaker (MCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563497757,"sku":"A9F77120","price":346.23,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9F77120-Miniaturecircuit-breaker_Acti9iC60N_1P_20A_Ccurve_10kASchneiderElectric.jpg?v=1779226682"},{"product_id":"schneider-electric-acti9-ic60n-mcb-1p-25a-10ka-a9f77125","title":"Schneider Electric A9F77125 Acti9 iC60N MCB 1P 25A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F77125 is a 1-pole, 25A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F77125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F77125 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 25A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F77125 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F77125 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9F77125 from Spark Egypt and receive an original miniature circuit breaker (MCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563563293,"sku":null,"price":346.23,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9F77125-Miniaturecircuit-breaker_Acti9iC60N_1P_25A_Ccurve_10kASchneiderElectric.jpg?v=1779225511"},{"product_id":"schneider-electric-acti9-ic60n-mcb-1p-32a-10ka-a9f77132","title":"Schneider Electric A9F77132 Acti9 iC60N MCB 1P 32A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F77132 is a 1-pole, 32A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F77132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F77132 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 32A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F77132 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F77132 in Egypt\u003c\/h2\u003e\u003cp\u003eSpark Egypt supplies the original Schneider Electric A9F77132 miniature circuit breaker (MCB) with a VAT tax invoice for electrical contractors, panel builders, factories, consultants and facility-maintenance teams. Delivery is available to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt. Our technical team can confirm ratings, compatible accessories and equivalent references before you order, and project quantities are quoted on request.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563596061,"sku":null,"price":346.23,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9F77132-Miniaturecircuit-breaker_Acti9iC60N_1P_32A_Ccurve_10kASchneiderElectric.jpg?v=1779225246"},{"product_id":"schneider-electric-acti9-ic60n-mcb-1p-40a-10ka-a9f77140","title":"Schneider Electric A9F77140 Acti9 iC60N MCB 1P 40A C-Curve 10kA | Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F77140 is a 1-pole, 40A C-curve miniature circuit breaker from the Acti9 iC60N range with 10kA breaking capacity – the most widely specified Acti9 MCB for commercial buildings, residential towers and light-industrial panels. It protects cables and equipment against overloads and short circuits in single-phase final circuits, and is installed on a standard DIN rail inside distribution boards and control panels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eC-curve tripping characteristic suited to general loads such as lighting, sockets, air conditioners and small motors (trips at 5–10 × In)\u003c\/li\u003e\n\u003cli\u003e1-pole design for single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 10kA\u003c\/li\u003e\n\u003cli\u003ePositive contact indication – the handle shows the real contact position for safe isolation\u003c\/li\u003e\n\u003cli\u003eFast clip-on mounting on 35 mm DIN rail and compatibility with standard comb busbars\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 auxiliaries (auxiliary contacts, shunt trips, Vigi earth-leakage add-ons)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003ePart number (SKU)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eA9F77140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eProduct range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eActi9 iC60N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eDevice type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eNumber of poles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated current (In)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eTripping curve\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e230\/240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003e35 mm DIN rail, 18 mm per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;background:#f6f7f7;text-align:start;width:40%\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eApartment, villa and office distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, malls, hospitals and hotels\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and air-conditioning circuits\u003c\/li\u003e\n\u003cli\u003eControl panels, pump panels and HVAC panels\u003c\/li\u003e\n\u003cli\u003eReplacement of old or faulty MCBs during maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection guide\u003c\/h2\u003e\u003cp\u003eMatch the rated current to the cable size of the circuit (for example 10 A for 1.5 mm² lighting, 16–20 A for 2.5 mm² sockets and 25–32 A for 4–6 mm² air-conditioner lines), choose the curve according to the load inrush, and make sure the breaking capacity is higher than the prospective short-circuit current at the board. For earth-leakage protection, combine the MCB with an Acti9 RCCB or use an RCBO.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eWhat is the A9F77140 used for?\u003c\/h3\u003e\u003cp\u003eIt is a 1P 40A C-curve MCB used to protect single-phase final circuits against overload and short circuit in residential, commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eCan the A9F77140 protect against electric shock?\u003c\/h3\u003e\u003cp\u003eNo. An MCB protects cables against overload and short circuit only. For protection against earth leakage and electric shock, add a 30 mA RCCB (residual current circuit breaker) upstream or use an RCBO.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the C curve and the B or D curves?\u003c\/h3\u003e\u003cp\u003eA C-curve breaker trips magnetically between 5 and 10 times its rated current and suits most general loads. B curve (3–5 × In) is for resistive loads and long cables, while D curve (10–20 × In) is for transformers and motors with high inrush current.\u003c\/p\u003e\n\u003ch2\u003eBuy Schneider A9F77140 in Egypt\u003c\/h2\u003e\u003cp\u003eOrder the Schneider Electric A9F77140 from Spark Egypt and receive an original miniature circuit breaker (MCB) with an official tax invoice. We deliver to Cairo, Giza, New Cairo, 6th of October, Sheikh Zayed, the New Administrative Capital, Alexandria, the Delta, the Canal cities and Upper Egypt, and our engineers help contractors, panel builders and maintenance teams check ratings, accessories and cross-references before purchase. Request a project quotation for bulk quantities.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51263563661597,"sku":null,"price":346.23,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5558\/3005\/files\/A9F77140-Miniaturecircuit-breaker_Acti9iC60N_1P_40A_Ccurve_10kASchneiderElectric.jpg?v=1779225000"}],"url":"https:\/\/www.spark-eshop.com\/collections\/application-panel-building-applications.oembed?page=65","provider":"Spark","version":"1.0","type":"link"}